Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 498-507 
    ISSN: 0021-9304
    Schlagwort(e): endovascular grafts ; ePTFE ; balloon angioplasty ; stents ; biomaterial ; Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: The search for less invasive treatments for cardiovascular disease has lead to the development of endovascular stent grafts, metallic and alloy stents surrounded by prosthetic vascular graft material. Introduced intravascularly, the deployment of stent grafts requires balloon dilatation of the device which results in expansion of the stent along with the vascular graft material. We hypothesized that balloon dilatation of stent grafts would alter the physical structure of the prosthetic graft material. In this study, noncompliant angioplasty balloons were used to dilate expanded polytetrafluoroethylene (ePTFE), a material commonly used for endovascular stent-graft technology. The maximal outer diameter (inflated balloon within the lumen) and the recoiled outer diameter (balloon removed) of two types of ePTFE, 3-mm inside diameter (i.d.) thin wall (30-μm internodal distance) and 4-mm i.d. standard wall (30-μm internodal distance), were measured to compare material recoil. Following balloon dilatation, ePTFE samples were prepared for scanning electron microscopic examination and the following parameters were measured: wall thickness, internodal distance, nodal width, interfiber distance, and fiber width. Following primary dilatation, both types of ePTFE recoiled approximately 20% regardless of inflated balloon diameter. However, following eight repetitive balloon dilatations, recoil decreased to approximately 10%. Scanning electron microscopic analysis revealed variations in internodal distance and significant decreases in wall thickness, nodal thickness, and interfiber distance. Fiber width was significantly decreased following dilatation of 3 mm, but not 4 mm ePTFE. Our data support our initial hypothesis that balloon dilatation alters the structure of ePTFE. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 36, 498-507, 1997.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 34 (1997), S. 463-476 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Healing of biomaterial implants varies depending on the type and structure of material and the tissue surrounding the implant. In this study we examined structural differences of 30 μm, 60 μm, and 100 μm expanded polytetrafluoroethylene (ePTFE) using scanning electron microscopy, and we also investigated differences in healing for these three different porosity ePTFE grafts implanted within subcutaneous tissue and adipose tissue. Scanning electron microscopic examination of 30 μm, 60 μm, and 100 μm ePTFE revealed structural differences and differences in fiber density within the internodal space. Circular patches (6 mm in diameter) of 30 μm ePTFE were implanted within subcutaneous tissue and epididymal fat pads of male Sprague-Dawley rats. After 5 weeks, the implants were removed and analyzed for fibrous capsule formation, endothelialization, and for activated monocytes and macrophages in association with the material. Histological evaluation revealed dense fibrous capsule formation surrounding only the 30 μm ePTFE subcutaneous implants. From immunohistochemistry data obtained, we generated an Endothelialization Index (measure of neovascularization) and a Monocyte/Macrophage Index (measure of inflammatory response) for each sample. Consistently, 60 μm ePTFE had the greatest Endothelialization Index at both implant sites while 100 μm ePTFE generally had the largest values for the Monocyte/Macrophage Index. These data indicate that both the structure of the material and the site of implant influence the healing characteristics of ePTFE and suggest that activated monocytes and/or macrophages associated with the implant may inhibit endothelialization of ePTFE. © 1997 John Wiley & Sons, Inc.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 41 (1998), S. 364-370 
    ISSN: 0021-9304
    Schlagwort(e): polymers ; endovascular grafts ; healing ; inflammation ; neovascularization ; Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Deployment of endovascular grafts composed of a metallic stent surrounded by expanded polytetrafluoroethylene (ePTFE) stretches the polymer beyond its original dimensions, altering the structural characteristics of the ePTFE. We hypothesized this structural modification would alter the healing response associated with the implant. In this study, 4 mm i.d. of ePTFE (30 μm internodal distance) vascular grafts were balloon dilated using angioplasty balloons having final diameters of 6 (1.5X), 8 (2X), 10 (2.5X), 12 (3X), and 18 (4.5X) mm. Following balloon dilatation of the ePTFE, a circular punch (6 mm in diameter) was used to prepare polymer samples for implantation. The ePTFE circular patches were implanted within subcutaneous tissue and epididymal fat pads of male Sprague-Dawley rats. After 5 weeks, the implants were removed and analyzed for fibrous capsule formation, inflammation, and neovascularization associated with the material. Histological analysis revealed the formation of fibrous capsules only with control subcutaneous implants. The inflammatory response associated with subcutaneously implanted ePTFE was decreased significantly following balloon dilatation to at least 2.5 times the original diameter of the graft. In contrast, ePTFE implanted within adipose tissue demonstrated a significantly greater inflammatory response following balloon dilatation when compared to control implants. Only ePTFE balloons dilated to 6 mm and implanted within adipose tissue demonstrated neovascularization to any extent. These data suggest the structural modifications incurred by ePTFE following balloon dilatation dramatically affect the inflammatory response associated with an implant. Therefore, polymeric materials used for endovascular graft technology require designs that consider changes in polymer healing inherent to device design. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 41, 364-370, 1998.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...