Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1084
    Keywords: Key words: Neobladder ; Continent urinary diversion ; 3D CT imaging ; Virtual endoscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The aim of this pilot study in 54 patients was to improve the visualization of the anatomy and postoperative changes in the pelvic topography after bilateral ureteroileal urethrostomy, using surface rendering of electron beam CT (EBCT) data for the 3D display. Fifty-four patients (39 men and 15 women) were scanned with an EBCT unit between 3 and 110 months after performing orthotopic ureteroileal urethrostomy (“Hemi-Kock”) or ureteroileal rectosigmoidostomy. Various parameters and spatial viewing points were used in the 3D reconstruction, which was performed interactively on external workstations with commercially available software. The anti-reflux nipple was visualized as a distinct structure in all patients. In 8 patients with an interval of more than 12 months between surgery and CT, the pouch had developed an ovoid shape almost indistinguishable from the original bladder. The segmented data sets were partly animated to display the anatomy as virtual endoscopy. Three-dimensional depiction and virtual endoscopy of the neobladder using EBCT are a new way of imaging the postoperative anatomy. Its clinical efficacy in the diagnosis of inconclusive postoperative morbidity, especially voiding problems, and planning of necessary therapy have to be the subject of further evaluation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International urogynecology journal 10 (1999), S. 248-253 
    ISSN: 1433-3023
    Keywords: Key words:Digital imaging processing – Neobladder – Pelvic anatomy – 3D-CT – Urinary diversion – Virtual endoscopy – Virtual reality
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract: Advances in computerized and imaging technology permit both students and doctors to depict the anatomy of the human pelvis more realistically than with previous methods. Further refinements outline fine pelvic structures, such as the nerve plexus, which may as a result be spared during major pelvic surgery, thus preserving the function of the bladder neck and urethra. Dynamic computerized tomography or magnetic resonance imaging, coupled with three-dimensional depiction of the lower urinary tract and its adjacent structures, enable visualization of the whole lower urinary tract and the pelvic floor musculature in both continent and incontinent women. In patients with a reconstructed lower urinary tract computer-assisted image processing shows the postoperatively altered topographical anatomy. This may be clinically useful for interpretation of unexpected findings with conventional imaging modalities, postoperative morbidity, and surgical planning of a lower abdominal reoperation. Examples of our own work regarding the innervation of female pelvic organs, dynamic depiction of the bladder and pelvic floor musculature during straining in normal and incontinent women, and the situation of female patients after undergoing an anterior pelvic exenteration with subsequent orthotopic neobladder procedure, are given. In addition, the data of these patients have been compiled for virtual reality endoscopy, which is useful for patient consent and for teaching residents, students and nurses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-5233
    Keywords: Phlebotomist ; Bedside glucose monitoring ; Quality control
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A feasibility study was undertaken to evaluate laboratory phlebotomists performing bedside glucose monitoring (BGM) over a 3-month period on a medical and surgical floor. Specific questions included: feasibility of providing testing on a 24-h basis, accuracy, appropriate utilization, effect on patient care, and an analysis of cost. In all, 1975 tests were performed on 114 patients. BGM results were within 15% of the laboratory's result 97% of the time. Patient and physician satisfaction was high. Although the cost of BGM is slightly higher than a laboratory glucose test, its use appeared to reduce the length of hospital stay by 0.47 days. Practical information on initiating a highly successful BGM program is provided.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Journal of superconductivity 8 (1995), S. 567-570 
    ISSN: 1572-9605
    Keywords: Antiferromagnetism ; Optical properties ; Heisemberg model
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Abstract Recent measured bands in the mid IR of parent insulating compounds of cuprate superconductors [Perkins et al. Phys. Rev. Lett.71 1621 (1993)] are interpreted as multimagnon infrared (IR) absorption assisted by phonons. We present results for the coupling constant of light with this excitations and exact diagonalization results for the spectra and compare with interacting spin wave theory. The observed structures correspond to the absorption of one phonon plus two magnons and one phonon plus higher multimagnon absorption processes. Our results imply that IR absorption can be used as a unique probe of quantum antiferromagnetic systems.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...