Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 3371-3371 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We have developed a digital x-ray processor (DXP) for x-ray fluorescence spectroscopy, implemented in a 4-channel CAMAC module, which accepts inputs of either polarity from reset or tail preamplifiers, and outputs one spectrum per channel. Digital trapezoidal shaping and efficient pileup rejection are implemented in dedicated logic, with programmable peaking times from 0.5 to 20 msec. The energy resolution is comparable to good analog units at equivalent peaking times. A maximum input count rate (ICR) of 500,000 cps per channel can be accomodated at a peaking time of 0.5 msec. A digital signal processor on each channel is used to collect the data, apply corrections, and update the spectrum. The capabilities of the DXP prototype at high rates was tested at SSRL. Using an Ortec single-element germanium detector, the resolution was seen to degrade somewhat with increasing ICR above 150,000 cps, due to effects that we are still investigating. Collaborating with Hewlett-Packard and SSRL, the DXP was also used with a Kevex Si(Li) detector for trace element detection on silicon wafers in comparison with Kevex readout electronics. At 4 msec peaking time, DXP's resolution was slightly worse (10–15 eV) due to some excess noise pickup, though the background levels in the spectra were essentially identical in the two systems and the DXP's maximum count rate was several times higher. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of radioanalytical and nuclear chemistry 233 (1998), S. 233-239 
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The XIA DXP-4C, a 4 channel, CAMAC based X-ray spectrometer, is based on digitally processing directly digitized preamplifier signals. Designed for instrumenting multi-detector arrays for synchrotron radiation applications, the DXP-4C was optimized for very high count rates at a low cost per detector channel. These design constraints coincidentally lead to an instrument which is very compact and relatively low power (3.4 W/channel), considering its count rate and MCA capabilities, and which therefore offers interesting possibilities for effective extension to portable applications. Further, because all functions (gain, filter parameters, pileup inspection criteria and internal calibrations) are digitally controlled, the design can be readily adapted to a large variety of user interfaces, including remote access interfaces. Here we present the basics of the design and examine approaches to lowering the power to less than 300 mW/channel while retaining count rate capabilities in excess of 50,000 cps. We then consider the engineering issues associated with portable and remote spectrometry applications, examining in detail the three cases of a lead paint detector, a remote contamination monitor, and a space mission spectrometer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...