Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Macromolecules 28 (1995), S. 1003-1007 
    ISSN: 1520-5835
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0428
    Keywords: Key words Human insulin ; porcine insulin ; brain ; insulin receptor ; insulin degradation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Previous studies have suggested that human and porcine insulin exert identical effects on blood glucose and counter-regulatory hormones but elicit different neurophysiological reactions. A major goal of the present study was to investigate whether this could be caused by different relative affinities of the insulins from different species to insulin receptors from the brain compared to other tissues. Insulin receptors isolated from human brain, muscle or adipocytes as well as from cultured cells over-expressing either of the human insulin receptor isoforms (exon 11– or exon 11 + ) were immobilized to microwells coated with monoclonal anti-insulin receptor antibody. Subsequently the binding of human, porcine and bovine insulin was measured. While the receptors derived from the different tissues had different affinities for insulin, there were no tissue-specific differences in the relative binding of the insulins of the three species. The insulins of the three species were also not different with regard to their binding to the receptor isoforms. Finally, in human brain homogenates no differences in the degradation rates for human, porcine and bovine insulin were detected. Thus, our data do not support the hypothesis that different neurophysiological reactions during hypoglycaemia due to human or porcine insulin are caused by differences of the binding of the insulins to human brain insulin receptors or their degradation in the human brain. [Diabetologia (1995) 38: 757–763]
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Diabetologia 39 (1996), S. 248-249 
    ISSN: 1432-0428
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-0428
    Keywords: Keywords Insulin receptor kinase ; compound heterozygous insulin receptor mutations ; human muscle ; erythrocytes ; congenital fibre type disproportion myopathy.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary We studied insulin receptor kinase activation in two brothers with congenital muscle fibre type disproportion myopathy and compound heterozygous mutations of the insulin receptor gene, their parents, and their unaffected brother. In the father who has a heterozygote Arg1174→Gln mutation, in situ activation of the receptor kinase in skeletal muscle was reduced about 70 %. Selection of only those receptors that bound to anti-phosphotyrosine antibody showed that these receptors had normal kinase activity and that the reduction in overall kinase activity was due to the inability of about 70 % of the receptors to become insulin-dependently activated. The mother carries a point mutation at the last base pair in exon 17 which, due to abnormal alternative splicing, could lead to normally transcribed receptor or truncated receptor lacking the kinase region. Kinase activation was normal in the mother's skeletal muscle, suggesting that virtually no truncated receptor was expressed. Receptor kinase activity was, however, reduced by 95 and 91 % in the compound heterozygous brothers. This suggests that the mother's mutated allele contributes little to the generation of functional receptor protein and that the receptors in the mother's skeletal muscle are transcribed almost exclusively from the non-mutated allele. The mutation in exon 17 could lead to reduced transcription or rapid degradation of a predominantly transcribed truncated gene product or both. [Diabetologia (1999) 42: 245–249]
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-0428
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    The journal of membrane biology 167 (1999), S. 43-52 
    ISSN: 1432-1424
    Keywords: Key words: HeLa cells — Inward rectifier — Cloning — Kir2.1 —Xenopus oocyte — Channel
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Abstract. Previous patch-clamp studies have shown that the potassium permeability of the plasma membrane in HeLa cells, a cell line derived from an epidermoid carcinoma of the cervix, is controlled by various K+-selective pores including an IRK1 type inwardly rectifying K+ channel. We used the sequence previously reported for the human heart Kir2.1 channel to design a RT-PCR strategy for cloning the IRK1 channel in HeLa cells. A full-length clone of 1.3 kb was obtained that was identical to the human cardiac Kir2.1 inward rectifier. The nature of the cloned channel was also confirmed in a Northern blot analysis where a signal of 5.3 kb corresponding to the molecular weight expected for a Kir2.1 channel transcript was identified not only in HeLa cells, but also in WI-38, ECV304 and bovine aortic endothelial cells. The HeLa IRK1 channel cDNA was subcloned in an expression vector (pMT21) and injected into Xenopus oocytes. Cell-attached and inside-out single channel recordings obtained from injected oocytes provided evidence for a voltage-independent K+-selective channel with current/voltage characteristics typical of a strong inward rectifier. The single channel conductance for inward currents measured in 200 mm K2SO4 conditions was estimated at 40 ± 1 pS (n= 3), for applied voltages ranging from −100 to −160 mV, in agreement with the unitary conductance for the IRK1 channel identified in HeLa cells. In addition, the single channel conductance for inward currents, Γ, was found to vary as a function of αK, the external K+ ion activity, according to Γ=Γ0 [αK]δ with Γ0= 3.3 pS and δ= 0.5. Single channel recordings from injected oocytes also provided evidence of a voltage-dependent block by external Cs+ and Ba2+. The presence of 500 μm Cs+ caused a voltage-dependent flickering, typical of a fast channel blocking process which resulted in a reduction of the channel open probability at increasingly negative membrane potential values. The fractional electrical distance computed for the Cs+ blocking site was greater than 1 indicating a multiple ion channel occupation. In contrast, external Ba2+ at concentrations ranging from 25 to 100 μm caused a slow channel block, consistent with the binding of a single Ba2+ ion at a site located at half the membrane span. It is concluded on the basis of these observations that HeLa cells expressed a Kir2.1 type inwardly rectifying channel likely to be involved in maintaining and regulating the cell resting potential.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 1066-1068 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A volume source based on the high efficiency source is being developed for heavy ion production. Bismuth was chosen for exemplifying investigations because of its low melting point. The ion source is driven by an arc discharge ionizing bismuth atoms which are evaporated from an oven inside the source chamber. It has been optimized to produce a beam with a fraction of singly ionized bismuth above 92%. A multiaperture extraction system was built consisting of seven holes with a radius of 3 mm each. For that system, the perveance limit was achieved at a beam current of 70 mA and an extraction voltage of 27.5 kV. The corresponding emission current density amounts to 35 mA/cm2. This value was obtained for an arc power of only 280 W. Furthermore, the emittance of a beam extracted from the multiaperture extraction system has been determined with a high power emittance scanner. It amounts to 0.27π mm mrad (80%, normalized, 4 rms). In this case, the emittance of a single beam is 0.017π mm mrad. This article will give a detailed description of both the source and the experimental setup. In addition, various dependencies between the plasma parameters and the beam composition are presented. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1054-1056 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A volume source, based on the high efficiency ion source (HIEFS), is being developed for D+ production in steady state operation. The source will be optimized for the extraction of atomic deuterium ions with high current densities. It was found that a maximum deuterium ion beam current density of 210 mA/cm2 can be achieved with a D+ fraction above 90%. At an extraction voltage of 35 kV and with an aperture radius of 4 mm, the source delivers 61 mA D+. After a description of the source and the experimental setup, the results of detailed studies of the beam composition in dependence of the plasma parameters are presented. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 2698-2706 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Among the various possibilities for investigating the properties of ion beams, two of the most important principles for determining the beam quality are profile measurements using wires or slit apertures, and different kinds of emittance measurement devices. However, most of the commonly used systems have the disadvantage of being either destructive to the beam, or at least to have a considerable influence on the further beam propagation downstream of the point of measurement. Also, for the investigation of intense ion beams, thermal problems on the scanners themselves might arise. Observation of particles emitted from the ion beam in radial direction allow an indirect but nondestructive observation of the beam. Of the different optical methods that exist to accomplish this, we recently conducted an investigation on the possibilities to employ a charge coupled device-camera system for such nondestructive beam diagnostics in our space-charge compensation test stand. First, experimental results on optical profile measurements are presented and compared to results obtained by a slit scanner and a wire scanner. Additionally, to gain a better understanding of the measured data, optically obtained sectional profiles behind a slit and a circular aperture were analyzed. Possibilities for gaining information on the two-dimensional beam profile and the beam emittance are explored. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1039-1041 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A new version of the high efficiency source is being developed for the European Spallation Source. The goal of these experiments is to produce a nearly pure H− ion beam with a low electron to H− ratio and high current (70 mA). To achieve this, the discharge chamber is divided into two parts of different plasma parameters by means of a filter magnetic field. Furthermore, the plasma chamber is aligned unsymmetrically with respect to the z axis of the extractor. We obtained a current density of 10 mA/cm2 for an arc power as small as 1 kW. In preliminary experiments, a beam of 10 mA was extracted at an extraction voltage of 8 kV (1.8% impurities). Measurements of the beam current density, electron to H− ratio, and the ion composition for a wide range of discharge conditions will be presented in this article. © 1996 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...