Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 117 (1995), S. 2923-2924 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 70 (1997), S. 1011-1013 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Electron-beam-induced current (EBIC) profiles of Mo/CuInX2/CdS/ZnO thin film solar cells with X=Se, S were recorded at different temperatures. We measure the collection efficiency of cells as a function of the beam energy and subsequently identify the depth dependent collection function. For a CuInS2 based cell, charge collection is maintained by diffusion transport of minority carriers to the junction with an effective diffusion length of 1.3±0.2 μm. This value is independent on temperature between 123 and 373 K. A CuInSe2 based cell exhibits increased collection of charge carriers created at the back contact on decreasing temperature. The temperature variation of the EBIC profiles is discussed considering the effect of bulk and grain boundary recombination. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    World journal of urology 13 (1995), S. 143-148 
    ISSN: 1433-8726
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary This review discusses the impact of molecular genetics on the diagnosis and prediction of the prognosis for renal-cell tumors. Through the use of molecular techniques, it has become possible to divide renal-cell tumors into genetically and biologically well-defined entities. The new classification has many advantages over morphological ones: (1) in contrary to tumor phenotype, genetic markers are constant during tumor progression and allow a precise diagnosis; (2) genetic analysis discriminates between papillary (multiple origin) and nonpapillary renal-cell carcinomas (solitary tumors); (3) genetic analysis allows a precise diagnosis of renal adenoma; (4) the new classification system offers a genetic prognostic system; and (5) the new diagnostic-prognostic system could easily be adapted to modern detection systems such as automated sequence and fragment-length analysis, which allow a quick and correct diagnosis with a high throughput.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1434-601X
    Keywords: PACS:21.10.Hw Spin, parity and isobaric spin – 23.20.Gq Multipole mixing ratios – 25.70.Gh Compound nucleus – 27.60.+j 90 ≤ A ≤ 149
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: The high-spin states of 147Tb have been studied with regard to their spins. The data were obtained by in-beam γ-ray spectroscopy using the reaction 120Sn(31P,4n)147Tb at 152 MeV performed at the Osiris spectrometer in Berlin. We obtained multipole mixing ratios for 60 transitions, and level spins up to 67/2ħ are introduced.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' journal of analytical chemistry 358 (1997), S. 141-143 
    ISSN: 1432-1130
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Investigations of the geometric and electronic properties of ternary Ce-based heavy fermion systems CeT2X2 (T : Ni,Pd,Rh; X : Ge,Si) were carried out by means of electron spectroscopic methods. The main problem for these surface-sensitive techniques is the preparation of well-ordered and atomically clean surfaces. The ternary substance CeNi2Ge2 was grown on a W(110) substrate by MBE with subsequent annealing. A nearly layer-by-layer growth mode was detected using MEED. The annealed layers are ordered, but show small Ni2Ge crystalline islands. The composition was characterised by means of AES in dependence of the substrate as well as the annealing temperature. Electronic properties are investigated by angle resolved photoelectron spectroscopy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Der Internist 38 (1997), S. 1131-1142 
    ISSN: 1432-1289
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Nach vielen Jahren der Stagnation zeigen sich Fortschritte bei der Therapie niedrig-maligner Non-Hodgkin-Lymphome. Vielversprechende Ergebnisse gibt es von gut kontrollierten randomisierten Studien, die einen Vorteil der Interferon-Erhaltungstherapie bei zentroblastisch-zentrozytischen Lym-phomen zeigen. Purinanaloga werden in Zukunft die Therapiemöglichkeiten der Patienten sicherlich ebenfalls verbessern. Dies wurde bei der chronischen lymphatischen Leukämie bereits gezeigt und betrifft in Zukunft sicherlich auch andere Lymphomentitäten. Die vielversprechendste Neuerung ist sicherlich die Hochdosistherapie mit Stammzell-Transplantation, die sich beim Plasmozytom und beim rezidivierten hochmalignen NHL bereits in prospektiv randomisierten Studien einer konventionellen Therapie als überlegen erwiesen hat.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 72 (1999), S. 255-260 
    ISSN: 1432-1246
    Keywords: Key words Environmental medicine ; Environmental toxins ; Biological monitoring ; Reference values ; Human biological monitoring (HBM) values
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract This article describes the working principles and working procedures of the Commission on Human Biological Monitoring, which was established in 1993 as a joint commission of the Federal Health Office (Bundesgesundheitsamt) and the Federal Environmental Agency (Umweltbundesamt) in Germany. One of the main tasks of the commission is to develop scientifically based criteria for the application of human biological monitoring and for the evaluation of human monitoring data in environmental medicine. In principle, two different kinds of criteria are recommended: (a) reference values and (b) human biological monitoring values (HBM values). Reference values are intended to indicate the upper margin of the current background exposure of the general population to a given environmental toxin at a given time. Reference values can be used to identify subjects with an increased level of exposure (in relation to background exposure) to a given environmental toxin. However, reference values do not represent health-related criteria for the evaluation of human biological monitoring data. HBM values are derived from human toxicology and epidemiology studies and are intended to be used as a basis for a health-related evaluation of human biological monitoring data. Usually the commission recommends two different HBM values: HBM I, the concentration of an environmental toxin in a human biological material (usually blood, serum, plasma, or urine) below which there is – according to the knowledge and judgement of the commission – no risk for adverse health effects in individuals of the general population; and HBM II, the concentration of an environmental toxin in a human biological material (usually blood, serum, plasma, or urine) above which there is – according to the knowledge and judgement of the commission and with regard to the environmental toxin under consideration – an increased risk for adverse health effects in susceptible individuals of the general population. The HBM I value can be considered a kind of alert value (from the toxicological point of view), whereas the HBM II value represents a kind of action level, at which attempts should be undertaken to reduce the level of exposure immediately and to carry out further medical examinations. Values between HBM I and HBM II should be considered a warning signal of the need to control the analytical measurement and to reduce the level of exposure of the concerned individual as reasonably as is achievable. At present, reference and HBM values are available for lead in blood, for cadmium and mercury in blood and urine, and for pentachlorophenol in plasma/serum and urine. Reference values have been established for some polychlorinated biphenyls in blood and plasma as well as for hexachlorocyclohexane and hexacholorobenzene in blood as well as for some organochlorine in human milk.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-2102
    Keywords: Key words MR angiography • Time of flight • Phase contrast • Peripheral arteries ; Schlüsselwörter MR-Angiographie • Time-of-Flight • Phasenkontrast • Periphere Gefäße
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Ziel der Studie war die Entwicklung einer praktikablen Untersuchungsstrategie für die MRA der unteren Extremität. Im Probandenteil der Studie wurden 3 MRA-Techniken (2D-TOF mit venöser Sättigung, 3D-Magnitude-Kontrast und 2D-Phasenkontrast mit EKG-Triggerung) intraindividuell prospektiv verglichen. Im Patiententeil der Studie wurden bei n = 45 klinischen MRA-Untersuchungen mittels EKG-getriggerter 2D-PCA 230 Gefäßsegmente intraindividuell mit der arteriellen DSA nach einem fünfstufigen Scoresystem verglichen. EKG-getriggerte PCA-Techniken zeigten die beste Bildqualität in allen Gefäßabschnitten. Dabei betrug der mittlere Rang des Friedman-Testes der PCA-Technik in der Beckenetage 1,2 und an der Oberschenkel- bzw. Knie-/Unterschenkeletage 1,0. Die Patientenuntersuchungen zeigten eine gute Übereinstimmung von DSA und MRA mit einem signifikanten Spearman-Korrelationskoeffizient für die Becken-, Oberschenkel- und Knieetage. MRA-Untersuchungen der unteren Extremität sind unter Einsatz der EKG-getriggerten 2D-PCA-Technik mit vertretbarem Zeitaufwand möglich. Die Abbildungmöglichkeiten der untersuchten Gefäßetagen entsprechen den Bildeinstellungen der DSA und die klinische Auswertung ergab eine gute (Kappa 〉 0,61) bis sehr gute (Kappa 〉 0,81) Übereinstimmung in der Beurteilung pathologischer Gefäßveränderungen.
    Notes: Summary Purpose: To investigate whether phase-contrast MRA is a clinically suited approach to examine arteries of the pelvis and lower extremities. Methods: The study was divided into two parts, a volunteer study and patient study. Three MRA techniques – 2D TOF with venous saturation, 3D magnitude contrast and 2D phase contrast with ECG triggering – were intraindividually compared in 15 volunteers and evaluated by three blinded readers. Subsequently, a total of 230 vessel segments of 45 MRA studies using ECG-triggered phase contrast were compared with intraarterial DSA. All vessel segments were scored by three blinded readers using a five-point scale with DSA serving as the gold standard. Results: ECG-triggered phase contrast provided better image quality than the other MRA techniques as assessed by the Friedman test. Clinical studies demonstrated a significant correlation of DSA and MRA as assessed by the Spearman correlation and kappa statistics for individual readers. Conclusion: MRA of the pelvis and lower extremities may be performed with 2D ECG-triggered phase-contrast MRA within a reasonable time frame ( 〈 30 min). MRA slabs provide orientation similar to that with DSA projections and good to very good correlation of vessel pathology as shown by kappa statistics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1435-4373
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1434-601X
    Keywords: 21.60.Cs ; 21.60.Ev ; 27.60.+j
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Above-yrast states in the one-ptoton nucleus147Tb were studied in144Sm(6Li,3n)γ- and electron-measurements at the Coulomb barrier. Together with data from a separate study of147Dyβ-decay, members of all ten particle×phonon configurations of147Tb were identified, including the completeπh11/2×3− and πs1/2×3− octupole multiplets.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...