Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 70 (1999), S. 1447-1451 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An investigation of strain and temperature characteristics of Yb-doped fibers has been carried out in this article. Results obtained are compared with those reported on Nd-doped fibers, showing that the lifetime variation rate of the single mode Yb-doped fiber with increasing strain is temperature independent, and within experimental error similar to that of Nd, although in each case, the fiber modes, the dopant concentration level, and the rare earth ion itself are different. Their stable behavior may form the basis of a dual element sensor with which to obtain stress and temperature information independently in so-called "smart structures." © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 2764-2766 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An investigation of lifetime characteristics of fluorescence, over the wavelength region ∼1.5 μm from pumped Er-doped fibers of various activator concentrations, at temperatures up to ∼950 °C, has been carried out and a significant variation of fluorescence lifetimes with temperature was seen. The results have an impact upon the use of laser or stimulated emission processes at much higher temperatures and for lifetime-based, fiber-optic temperature sensors, showing a very favorable characteristic for such latter applications. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 2930-2934 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A fluorescence-based intrinsic doped fiber temperature sensing system for determining local extremes of high temperatures has been demonstrated in this work. Data on this temperature rise are analyzed using a mathematical relationship, based on a correlation coefficient ratio scheme, to relate to the reduced fluorescence decay time information thus associated with the hot part of the fiber. In schemes incorporating this mathematical analysis, two separate sensor configurations have been demonstrated, one of which is to use short, single lengths of fiber spliced into a network and the other a long single length of doped fiber, using both Nd and Er doped fiber materials. The results show that the correlation coefficient ratio, R, will deviate from and be smaller than unity with the increase of the temperature of the localized region where the heat is applied, providing the mechanism for a simple high temperature excursion detection system. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 1716-1723 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Average, rather than point specific temperature measurement is important in a number of industrial situations. In this work, a method to improve this type of measurement using the fluorescence lifetime-related mathematical parameter, the singular value (SV), is discussed in detail. The analysis reported shows that with rare-earth doped fibers used as temperature sensor probe elements, for average temperature measurement, such a system works well especially when the lifetimes obtained from different sensing probes are very close to each other. The SV scheme, based on matrix theory, is important because the average temperature-dependent singular value possesses the characteristics of both high speed and high precision. Using the method, an average temperature sensing scheme is demonstrated in experiments carried out over the region from 20 to 100 °C, in which Nd3+ doped fibers are employed as the intrinsic temperature sensor elements. When two temperature sensing probes are used in the measuring region, the precision determined for the average temperature estimation is ±3.6 °C. When three sensors are employed instead of two, the precision is similar at ±3.4 °C. Results obtained indicate that with more sensor elements used in the sensing region, the accuracy achieved is not diminished due to the averaging effect in the measurement. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 139-145 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A detailed investigation of the practical spectroscopic features and the effect of prolonged exposure to elevated temperatures of an intrinsic Nd:doped fiber optic thermometer probe using the fluorescence decay time technique has been carried out. Results have shown the optimum length for the doped fiber and a maximum operating temperature of 750 °C, beyond which a range of high-temperature "annealing" effects are seen. These are discussed in light of the operation of the thermometers over the range from −196 to 750 °C and potentially above. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 146-151 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The use of multiple material fluorescence-based sensors, where each is optimized to a particular temperature range yet is pumped by the same light source, emitting over the same spectral region, makes for a very simple, convenient and promising optical arrangement which can be applied in real-time, quasidistributed temperature sensor systems. The fluorescence lifetime approach, which is an important technique to enable fluorescence emission to be exploited for thermometry, is adopted in the system discussed. An analysis scheme using Prony's method has been reported which enables exponential decays from either single-material or two material and quasidistributed sensors to be deconvolved and thus data and associated measurand information encoded in each individual signal to be recovered. In this work, in the development of quasidistributed temperature sensor algorithms based on Prony's method are used for the estimation of exponential time constants of a convolved triple exponential fluorescence decay, each corresponding to a different-point temperature. Experimental results obtained are presented to justify their use in practical multiexponential fluorescence decay analysis and show a comparison of the Prony method to the Marquardt nonlinear least-squares approximation algorithm to achieve the deconvolution. The computational time for Prony's approach is approximately one-thousandth that of the Marquardt technique while the accuracy achieved using Prony's method is still high enough for practical use. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 3442-3446 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An analysis of the fluorescence decay behavior of alexandrite emission, at higher dopant concentrations, has been undertaken for optical sensor application purposes. A double exponential decay behavior of the fluorescence emission has been observed, which differs from the single exponential behavior of alexandrite at lower concentrations of the active Cr 3+ ion. The origin of the phenomenon has been investigated both experimentally and theoretically and found to be produced by the joint contribution from the Cr3+ dopant in both the mirror, as well as in the inversion sites of that ion. The two lifetimes resulting, each having a different temperature dependence, both can be represented through the use of the configurational coordinate model which considers the effect of thermal quenching. The intensity ratio of these two aspects is seen to change regularly with the temperature within the important region for sensing of 273–773 K, and thus provides an alternative means to produce a calibrated fluorescence-based sensor. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 3447-3451 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An analysis of the fluorescence decay behavior of Pr 3+ in ZBLAN glass, at different concentrations, has been undertaken, for applications of the material to fiber optic thermometry. The study has shown that with the temperature increase, the measured lifetimes of the fluorescence emission from the Pr 3+ doped glass are also seen to increase slowly. The results obtained are found not to support a simple two-level model based on the thermalization of the states involved but a new three-level model that has been introduced can explain the observed results in a very satisfactory way. The application of the work in optical thermometry is discussed and comparisons with other systems are made. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 58-63 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Algorithms based on Prony's method are proposed for the estimation of exponential time constants of a double exponential fluorescence–decay process. The performance of these algorithms is evaluated, using Monte Carlo simulations, the results of which are presented showing that the performance of Prony's method can be greatly improved with the selection of an optimized observation window width and a few algorithm-related parameters. The applications of these noniterative algorithms in real-time, quasidistributed temperature sensor systems are discussed where the material decay may not approximate to a single exponential, or multimaterial sensors are used with a single, simple pump source and a single detector. Applications to quasidistributed sensor systems are considered and, thus, experimental results are presented to justify the use of the algorithms in Prony's method in practical double exponential fluorescence decay sensor analysis. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 2924-2929 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The use of rare-earth-doped fibers for high temperature measurement has shown considerable promise. In this work, studies of the key characteristics of the performance of Er-doped fiber-based thermometer probes using the fluorescence decay time technique were carried out. Results showed the effects of fluorescence intensity as a function of doped fiber length and temporal and dopant concentration features of the probes. Annealing effects were seen to occur, and a satisfactory stable performance at up to 1100 °C was reported from this material, yielding improvement on results obtained with Nd-based systems. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...