Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (6)
  • 2000-2004  (1)
  • 1990-1994  (4)
  • 1985-1989  (1)
Source
  • Articles: DFG German National Licenses  (6)
Material
Years
Year
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 3112-3119 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We describe a system of capacitive transducers applied to two free falling objects with the aim of detecting differential accelerations due to nonNewtonian components. The two objects have a cylindrical shape to minimize the systematic errors and they fall in a microgravity condition inside a vacuum tube released by a stratospheric balloon at an altitude of 40 km. The calibration of the capacitive transducers performed in laboratory has shown that it is possible to detect differential accelerations Δa (approximately-less-than) 1.4 × 10−10 m s−2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 65 (1994), S. 1891-1893 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Picosecond optical pulses have been generated in different kinds of thresholdless dye microlaser operating in high-Q plane microcavities at high pumping rate. The temporal behavior of the system is studied by means of a simple rate equation analysis. It is shown that the buildup time of the output pulse is independent of the cavity finesse. The experiment has been performed by means of a temporally resolved up-conversion technique. A buildup time of the pulse of 3 ps, together with a rise time of 1.5 ps have been measured. These results correspond to a predictable response frequency of 300 GHz. © 1994 American Institue of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [s.l.] : Macmillian Magazines Ltd.
    Nature 419 (2002), S. 815-818 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] In classical computation, a ‘bit’ of information can be flipped (that is, changed in value from zero to one and vice versa) using a logical NOT gate; but the quantum analogue of this process is much more complicated. A quantum bit (qubit) can exist simultaneously in a superposition ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 52 (1991), S. 117-121 
    ISSN: 1432-0649
    Keywords: 42.60D
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A colliding pulse mode-locked ring dye laser, pumped by an all-line small frame Ar+ laser has been used to generate stable pulses as short as 49 fs with pulse duration and stability similar to those obtained with the usual configuration where a single line of the pump is used. The effects of cavity alignment on the absorber saturation are presented and explained in terms of an analysis of stability of the ring cavity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-0649
    Keywords: 42.60D
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We present a multipass femtosecond amplifier pumped by a Nd-YAG laser where the gain medium is given by a variable length dye cell. This system allows amplification factors up to 5 · 106 and output pulse energies of 150 μJ, while restricting the contribution of amplified spontaneous emission to 0.5% of the total output energy, without using any saturable absorber stage. A detailed study of the output pulsewidth as a function of the duration of the input chirped pulse is also presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The methodology of the detection of (n, α) nuclear reactions by means of cellulose nitrate detectors is discussed with special reference to the reliability of the quantitative estimates. The discrimination of10B and6Li from the other isotopes is possible by using thin coloured detectors. The ratio of the number of tracks found at the level of a10B or5Li-enriched calibrating sample, and the number expected from theoretical calculation, i.e. the detection efficiency, P is generally below 1. P is fairly sensitive to the experimental conditions, and for precise quantitative measurements it must be determined separately for each different experiment. The gelatin, used for solidification of liquid samples is boron contaminated (almost 1 μmol natural B per g). It has been observed, especially with10B-enriched liquid samples, that part of the stable tracer under study is lost during sample preparation.6Li extra tracks appear at the rear face of “thick”, non-plastic-supported detectors. Boron diffuses in the cellulose-nitrate detectors with the diffusion coefficient of the order of 10−8 cm2·s−1. Therefore it requires rapid operations for microlocation of boron with high resolving power.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...