Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (4)
  • 1980-1984  (9)
  • 1915-1919  (3)
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 37 (1915), S. 1571-1589 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 41 (1919), S. 1264-1267 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 41 (1919), S. 2048-2051 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Advances in contraception 9 (1993), S. 83-91 
    ISSN: 1573-7195
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Resumé Les études portant sur la sáreté de la contraception intra-utérine sont en général fondées sur des études ne reflètant pas les changements dans les pratiques cliniques intervenus au cours des années et se rapportent à de nombreux types de DIU qui ne sont plus utilisés. Les études concernant les insertions de Multiload 375 et Copper T 380 effectuées depuis 1980, qui d'ailleurs reflètent mieux la pratique clinique actuelle, indiquent que ces DIU offrent un haut niveau de protection contre les grossesses et qu'ils sont associés à de faibles pourcentages de complications. S'agissant de la sûreté des DIU, il y a lieu de réévaluer l'opinion clinique actuelle à la lumière des résultats positifs obtenus avec ces dispositifs dans ce domaine.
    Abstract: Resumen Los estudios relativos a la seguridad de la anticoncepción intrauterina suelen basarse en estudios que no reflejan los cambios en las prácticas clínicas ocurridos con el correr del tiempo y que incluyen muchos tipos de DIU que ya no se utilizan. Los estudios relativos a las inserciones del Multiload 375 y Copper T 380 realizados después de 1980, y que reflejan mejor la práctica clínica actual, indican que estos DIU ofrecen un alto nivel de protección contra los embarazos y están asociados con bajos porcentajes de complicationes. En lo que respecta a la seguirdad de los DIU, es necesario evaluar nuevamente la opinión clínica actual a la luz de los resultados positivos obtenidos con estos dispositivos.
    Notes: Abstract Reviews of the safety of intrauterine contraception usually are based on studies that do not reflect changes in clinical practice that have occurred over time, and that include many types of IUDs that are no longer used. Studies of insertions of the Multiload 375 and Copper T 380 performed since 1980, which more accurately reflect current clinical practice, show that these IUDs provide a high level of protection against pregnancy and are associated with low rates of complications. Current clinical opinion regarding the safety of IUDs needs to be reassessed in light of the positive safety record of these IUDs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 4 (1983), S. 273-298 
    ISSN: 1572-9559
    Keywords: Fourier transform spectroscopy ; phase correction ; interferometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The correction of phase error in Fourier transform spectroscopy is discussed. Phase error is corrected by multiplying the inverse transform of the measured interferogram by e−iϕ(ω), where ϕ(ω) is the phase error in the spectrum. This error is determined from a low-resolution, two-sided interferogram. It is absolutely essential that the truncation-apodization function which multiplies the interferogram have an even part which is symmetric about the x=0 position. If this function is not properly located, large errors in the corrected spectrum can occur.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The structural investigation of the products arising from 28 days incubation of albumin with high glucose concentration and further enzymatic hydrolysis has been carried out by means of high-performance liquid chromatography/mass spectrometry (HPLC/MS) under plasmaspray conditions. By this approach many different compounds have been detected, and for most of them, possible structures have been proposed on the basis of literature data and molecular weight assignments.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 717-718 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Chemical weapons use, although prohibited by the 1925 Geneva Protocol, has been reported in several armed conflicts including the Iran/Iraq war. The use of these weapons during this conflict and the concern over possible use of chemical warfare (CW) agents during the Persian Gulf war has heightened international awareness and prompted many nations to pursue with incresed vigour the signature of a new Chemical Weapons Convention. The most recent draft of the Chemical Weapons Convention contains a number of provisions aimed at developing a treaty that will enable nations to ensure compliance by all signatory nations. Compliance monitoring will be required in a number of scenarios, including the verification of alleged use, the storage and destruction of chemical weapons stocks and ensuring that industrial sites are not illegally producing CW agents. It follows from this draft treaty that compliance monitoring will require a high level of sophisticated analytical support to ensure the establishment of an enforceable treaty. The United Nations Conference on Disarmament therefore formed a multi-national Technical Group on Instrumentation to address the analytical challenges confronting signatory nations.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 17 (1982), S. 81-85 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Phenol and five acyclic isomeric compounds have been investigated using electron impact and field ionization techniques, mass analysed ion kinetic energy spectrometry and collision induced dissociation mass analysed ion kinetic energy spectrometry. The kinetic energy release data corresponding to the elimination of carbon monoxide from the molecular ions show that at least two structures of the reactant ion are involved. The electron impact and field ionization collision induced dissociation mass analysed ion kinetic energy spectra indicate that under electron impact conditions, the phenol ion partially isomerizes to another ion structure. An isomerization of about 40% to the structure of cis-2-hexen-4-yn-1-al is in good accordance with the spectral data.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 17 (1982), S. 331-334 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Translational energy release measurments on metastable ions are used in the comparison of the structures of isomeric ions. Metastable ions, m2+, formed from m1+ ions as the result of a high energy process in the ion source are compared with isomeric metastable ions formed as daughters from fragmentation of metastable m1+ ions in a field. In the case of o-, m- and p-nitrophenol the structure of the [C5H5O]+ ions formed from [C6H5O]+ ions by these two independent methods is different as verified by comparison of the behaviour of [C5H5O]+ ions formed from several other compounds.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 16 (1981), S. 101-114 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Using nitrobenzene as an example, various ways in which a contemporary mass spectrometer can be utilized to yield a wealth of information about the compound studied are reviewed. Applying a variety of different techniques and procedures, in addition to the conventional low resolution mass spectrum, the following nitrobenzene spectra have been obtained: collision induced dissociation mass spectrum, mass analysed ion kinetic energy spectra, collision induced dissociation mass analysed ion kinetic energy spectra, spectra obtained at constant B/E, spectra obtained at constant B2/E, high voltage scans of metastable ion fragmentation processes, consecutive fragmentations in different field free regions, charge exchange mass spectra, charge stripping mass spectra, doubly charged ion mass spectra, chemical ionization mass spectra, negative ion mass spectra, negative ion mass analysed ion kinetic energy spectra, negative ion mass analysed ion kinetic energy collision induced dissociation spectra, charge inversion spectra, etc. The complementary types of information available from the above studies are discussed to show the unique versatility of mass spectrometry as a technique for the examination of organic compounds.
    Additional Material: 32 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...