ISSN:
0021-8995
Keywords:
Chemistry
;
Polymer and Materials Science
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
,
Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
,
Physics
Notes:
A procedure to verify the identity of hydraulic fluids (HF) type C and D U is described. Different gel filtration systems were tested to separate the constitutive components. After fractionation of the mixture, IR and NMR spectroscopy were tried for their suitability in verifying the identity of the different constituents. The combination of aqueous gel filtration chromatography and IR spectroscopy was found suitable to separate and identify the different components of HFC fluids. For HFD U fluids, a modified gel filtration system was used and NMR spectroscopy was necessary to give a decisive answer about their identity. © 1993 John Wiley & Sons, Inc.
Additional Material:
6 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/app.1993.070501210
Permalink