Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: This project developed an automated controller based on an artificial neural network and evaluated its applicability in a real-time environment. This capability was developed within the context of a small angle negative ion source on the Discharge Test Stand at Los Alamos. The controller processes information obtained from the beam current wave form, developing a figure of merit (fom) to determine the ion source operating conditions. The fom is composed of the magnitude of the beam current, the stability of operation, and the quietness of the beam. Using no knowledge of operating conditions, the controller begins by making of rough scan of the four-dimensional operating surface. This surface uses as independent variables the anode and cathode temperatures, the hydrogen flow rate, and the arc voltage. The dependent variable is the fom described above. Once the rough approximation of the surface has been determined, the network formulates a model from which it determines the best operating point. The controller takes the ion source to that operating point for a reality check. As real data is fed in, the model of the operating surface is updated until the neural network's model agrees with reality. The controller then uses a gradient ascent method to optimize the operation of the ion source. Initial tests of the controller indicate that it is remarkably capable. It has optimized the operation of the ion source on six different occasions bringing the beam to excellent quality and stability.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of chemical information and modeling 33 (1993), S. 609-615 
    ISSN: 1520-5142
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 62 (1991), S. 2828-2830 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We discuss the nature of errors which may occur when the spectra of random signals not obeying Gaussian statistics are measured with typical rf spectrum analyzers. These errors depend on both the noise statistics and the process used to detect the random signal after it has been passed through a narrow bandpass filter within the spectrum analyzer. In general, for random signals not obeying Gaussian statistics, the output of the bandpass filter must be measured with a square law detector if the resulting measurement is to be strictly proportional to the power spectrum of the input signal. We compare measurements of the power spectra of non-Gaussian noise using a commerical spectrum analyzer with its resident envelope detector, with measurements by the same analyzer fitted with a square law detector. Differences of about 5% were observed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 47 (1992), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Measurements from the upgraded Finapres 2300e continuous noninvasive blood pressure monitor, the Finapres 2300 and Colin oscillometric noninvasive blood pressure monitor were compared with invasive arterial line blood pressure readings. Fifteen young Chinese patients undergoing elective spinal surgery of more than 2 h duration had contemporaneous blood pressure measurements digitally recorded every minute. Data were analysed using methods described by Bland and Altman to assess agreement of noninvasive devices with an arterial line. Results showed that although the Finapres 2300e was significantly more accurate than the Finapres 2300 and Colin noninvasive blood pressure monitors it could not be recommended as a substitute for continuous arterial line blood pressure monitoring. Both Finapres devices demonstrated reductions in accuracy related to time (drift) and over-read diastolic and mean pressures by 5–8 mmHg throughout the range of mean arterial line pressures (bias). The Colin was consistently less accurate than the Finapress monitors and performed worst at low mean arterial line pressures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 48 (1993), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Blood pressure measurements associated with malapplication of a finger cuff were compared with contemporaneous intra-arterial pressure data in seven volunteers to determine the influence of cuff application on the accuracy of the Finapres 2300e. Systolic readings in all cuff positions differed from arterial line data by more than the recommended standard and tight and loose cuff applications under and over-read respectively, in all subjects. The results show the Finapres to be sensitive to small degrees of finger cuff malapplication which contribute to the bias on direct arterial comparison and limit the reliability of the instrument in clinical practice.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Optical and quantum electronics 26 (1994), S. 25-34 
    ISSN: 1572-817X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Physics
    Notes: Abstract We have performed a propagation-of-errors analysis on two methods used to determine the spatial parameters of a laser beam. We measured diameters of a diode laser beam focused by a 993 mm focal length lens. Measurement uncertainties of less than 1% can result in uncertainties greater than 200% in locating the beam waist of the laser. We compare the inherent uncertainties in the spatial parameters as obtained by the two methods. Longer focal length lenses and lens position can reduce this magnification of uncertainty, but would require large propagation distances.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1432-2013
    Keywords: Intracellular pH ; SNARF-1 ; Carotid body
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report the use of a new pH-sensitive dualemission fluoroprobe, carboxy-seminaphthorhodafluor-1 (carboxy-SNARF-1) for ratiometric recording of intracellular pH (pHi) in small isolated cells. The method is illustrated with pHi measurement in single type-1 cells (cell diameter ∼10 μm) isolated from the carotid body of the neonatal rat. Carboxy-SNARF-1 is loaded using bath application of the acetoxymethyl ester. When excited at 540 nm, the fluoroprobe gives strong, inversely related emission signals at 590 nm and 640 nm. Stable ratiometric recordings of pHi can be achieved from a single cell (pHi 8.5-6.5) for up to 50 min. Photobleaching of the probe is minimised by illuminating at relatively low light intensity (50 W xenon lamp with 0.2% transmission neutral density filter). The probe can be calibrated in situ using the nigericin technique and this is in good quantitative agreement with the independent null-point technique (extracellular weak acid/weak base application) of Eisner et al. (1989). This fluoroprobe offers certain advantages over the other commonly used probe for pHi 2′,7′-bis-(2-carboxyethyl)-5(and -6)-carboxyfluorescein (BCECF): (i) because of its two strong pH-sensitive peak emissions, SNARF displays a good signal-to-noise ratio for ratiometric recording at low light intensities; (ii) unlike BCECF, the dual emisson of SNARF requires no sequential mechanical switching of excitation filters, thus simplifying the epifluorescence set-up; (iii) because carboxy-SNARF-1 emission signals are at the yellow/red end of the visible spectrum, fluorescent drugs like amiloride, ethyl-isopropyl-amibride (EIPA), 4,4′-diisothiocyanostilbene 2,2′-disulphonic acid (DIDS) and cinnamate analogues do not interfere with the pHi recording, even when used at high concentrations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-2013
    Keywords: Carotid body ; Chemoreceptor ; Intracellular calcium ; Intracellular pH ; Extracellular pH ; Acidosis ; Hypercapnia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We have investigated the effects of acidic stimuli upon [Ca2+]i in isolated carotid body type I cells from the neonatal rat using indo-1 (AM-loaded). Under normocapnic, non-hypoxic conditions (23 mM HCO3 −, 5% CO2 in air, pHo=7.4), the mean [Ca2+]i for single cells was 102±5.0 nM (SEM, n=55) with 58% of cells showing sporadic [Ca2+]i fluctuations. A hypercapnic acidosis (increase in CO2 to 10%–20% at constant HCO3 −, pHo 7.15–6.85), an isohydric hypercapnia (increase in CO2 to 10% at constant pHo=7.4) and an isocapnic acidosis (pHo=7.0, constant CO2) all increased [Ca2+]i in single cells and cell clusters. The averaged [Ca2+]i response to both hypercapnic acidosis and isohydric hypercapnia displayed a rapid rise followed by a secondary decline. The averaged [Ca2+]i response to isocapnic acidosis displayed a slower rise and little secondary decline. The rise of [Ca2+]i in response to all the above stimuli can be attributed to no single factor other than to a fall of pHi. The hypercapnia-induced rise of [Ca2+]i was almost completely abolished in Ca2+-free solution, suggesting a role for Ca2+ influx in triggering and/or sustaining the [Ca2+]i response. These results are consistent with a role for type I cell [Ca2+]i in mediating pH/PCO2 chemoreception.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1573-7446
    Keywords: cattle ; chromatography ; gas chromatography ; HPLC ; mass spectrometry ; metabolite ; metoclopramide ; urine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The urinary metabolites of metoclopramide (4-amino-5-chloro-N-[2-diethylaminoethyl]-2-methoxybenzamide) were identified in cows. The drug was administered intravenously, voided urine was collected, and individual urine extracts were analysed by gas chromatography-mass spectrometry and high-performance liquid chromatography-photodiode array detection. The parent compound and one major metabolite (4-amino-5-chloro-N-[2-(ethylamino)ethyl]-2-methoxybenzamide) were common to all individuals. In addition to the parent and major metabolite, a second, minor metabolite was identified in two cows as 4-amino-5-chloro-N-[2-(diethylamino)ethyl]-2-hydroxybenzamide. The identity of the minor metabolite was confirmed by comparison with a standard synthesized by a new method. Metabolite identification and characterization in food animal species allows the design of safety and environmental impact studies and relative metabolite ratios between dose treatment groups.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...