  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Macromolecules 26 (1993), S. 1060-1064 
    ISSN: 1520-5835
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 68 (1990), S. 2493-2495 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We have fabricated a Si metal-oxide-semiconductor field-effect transistor with a 20-nm channel length using a novel step/edge technique. An Al gate is evaporated onto a step in the SiO2 gate oxide. A second Al gate, separated from the first by a plasma-enhanced chemical-vapor-deposited SiO2 layer, provides inversion layer extensions of the source and drain contacts. Electrical conductance measurements indicate a channel length approximately equal to the fabricated gate length.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We have demonstrated a new planarized all-refractory technology for low Tc superconductivity (PARTS). With the exception of the Nb-AlOx-Nb trilayer preparation, the processing is done almost exclusively within an advanced Si technology fabrication facility. This approach has allowed us to leverage highly off of existing state-of-the-art lithography, metal etching, materials deposition, and planarization capabilities. Using chemical-mechanical polish as the planarization technique we have fabricated Josephson junctions ranging in size from 0.5–100 μm2. Junction quality is excellent with the figure of merit Vm typically exceeding 70 mV. PARTS has yielded fully functional integrated Josephson devices including magnetometers, gradiometers, and soliton oscillators.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1435-1803
    Keywords: myocardial ischemia ; revascularization ; laser ; systolicperfusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Laser-induced intramyocardial revascularization (LIR) has been used to promote direct communications between blood within the ventricular cavity and that of the existing myocardial vasculature in an attempt to increase perfusion in patients with ischemic heart discase. This study was conducted to measure the effects of LIR channels on regional myocardial flood flow (microspheres), cardiac mechanics (sonomicrometers), and myocardial tissue pressures in 18 dogs. Under baseline hemodynamic conditions (mean HR=165.2±11.4 bpm, LVP=123.6±22.9/4.0±1.8 mmHg, AoP=112.8±27.1/77.0±22.5 mmHg), myocardial blood flow in laser-treated tissue (mean =1.11±.10 cc/min/gm before laser; .71±.19 cc/min/gm after laser) was reduced as compared to blood flow in control tissue (mean=1.12±.15 cc/min/gm before laser; 1.25±.22 cc/min/gm after laser). Regional myocardial systolic shortening (11.32%±3.82% before laser; 7.49%±2.86% after laser) was decreased by 33%. During simultaneous reversible ligation of the LAD and LCCA for 2 min, when intramyocardial channels represented the only tissue access for the injected microspheres, blood flow in laser-treated tissue was not increased above that of the control non-lasered tissue. However, regional blood flow was greater in laser-treated ischemic tissue (mean=.61±.12 cc/min/gm) than in untreated ischemic areas (mean=.04±.03 cc/min/gm) when left ventricular pressure (LVP) was acutely elevated (mean SLVP=207.0±16.1 mmHg). Using these measurements, a model is proposed to predict regional systolic pressure gradients between the left ventricular cavity and coronary intramyocardial vasculature required to permit restoration of blood flow to ischemic myocardium. We conclude that improved perfusion via laser-induced intramyocardial channels does not occur in otherwise normal myocardium exposed to acute coronary ligation and only small improvements in perfusion are noted when LVP is significantly elevated. Consideration of further clinical application of this approach is seriously cautioned awaiting additional experimental studies.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Infection 22 (1994), S. 233-237 
    ISSN: 1439-0973
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Conclusion The presence of resistant pneumococcal organisms has become a major problem in the world today. These organisms are responsible for changing the methodology required for susceptibility testing and for the newly proposed guidelines for resistance. These newly proposed MICs are still under consideration because of the limited data used for their establishment. The treatment of resistant pneumococcal infections outside of the central nervous system is not yet well standardized. Central nervous system infections should be approached with care and a knowledge of current recommendations for their therapy. We expect changes in the recommendations for therapy over the coming years until a standardized approach can be established.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1439-0973
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 20 (1993), S. 331-336 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The virtues of chemical inertness and low surface energy which make polytetrafluoroethylene (PTFE) a valuable engineering polymer also account for the difficulty in achieving structural adhesive bonds. While plasma surface treatment has proven to be the most effective means of maximizing strength and permanence of adhesive bonds with the most inert of engineering polymers, a simple plasma treatment has proven elusive for PTFE. The following studies evaluate two very different plasma processes, activation and deposition, as a means to achieve reliable and high-strength structural adhesive bonds. Sodium naphthalene-etched PTFE is used as a control. Presented are ESCA data which support a theory that improvement is limited by a weakened boundary layer of the PTFE.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 377-386 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Biomaterial-centered infection is an important cause of the failure of prosthetic implants and organs. Because neutrophils mediate host defense against infection, the effect of biomaterials on neutrophil superoxide release and the mechanism of that effect were investigated using three materials commonly employed in surgical practice. The graft materials were expanded polytetrafluorethylene (PTFE), polyurethane and woven dacron. Polystyrene, a commonly used laboratory support vessel, was also studied. Both polystyrene and polyurethane were activating, but serum inhibitable, whereas PTFE was nonactivating, and woven dacron was not activating unless serum was present. The signaling mechanisms used by these materials demonstrated time and material dependency. Pertussis toxin inhibition of G proteindependent activation had little or no effect on biomaterial induced activation, whereas FMLP-induced activation of the same biomaterial-associated cells was inhibited. Protein kinase C inhibition with staurosporine greatly inhibited polystyrene-induced activation, but had only a partial effect with polyurethane and even less effect with the activation associated with serum-treated woven dacron. These studies demonstrated that biomaterial contact-induced neutrophil activation differed from that described for cells in suspension, and showed that activation mechanisms on one material cannot be extrapolated to mechanisms on other materials. © 1994 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 26 (1992), S. 1039-1051 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Because periprosthetic infection remains a vexing problem for patients receiving implanted devices, we evaluated the effect of several materials on neutrophil free radical production. Human peripheral blood neutrophils were incubated with several sterile, lipopolysaccharide (LPS)- free biomaterials used in surgically implantable prosthetic devices: polyurethane, woven dacron, and Velcro. Free radical formation as the superoxide (O2-) anion was evaluated by cytochrome c reduction in neutrophils that were exposed to the materials and then removed and in neutrophils allowed to remain in association with the materials. Neutrophils exposed to polyurethane or woven dacron for 30 or 60 min and then removed consistently exhibited an enhanced release of O2- after simulation via receptor engagement with formyl methionyl-leucyl- phenylalanine. Enhanced reactivity to stimulation via protein kinase C with phorbol myristate acetate, however, was not consistently observed. The cells evalu- ated for O2- release during continuous association with the biomaterials showed enhanced metabolic activity during short periods of association (especially with polyurethane and woven dacron). Although O2- release by neutrophils in association with these materials decreased with longer periods of incubation, it was not obliterated. These studies, therefore, show that several commonly used biomaterials activate neutrophils soon after exposure and that this activated state diminishes with prolonged exposure but nevertheless remains measurable. The diminishing level of activity with prolonged exposure, however, suggests that ultimately a depletion of reactivity may occur and may result in increased susceptibility to periprosthetic infection.
    Additional Material: 1 Ill.