Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International ophthalmology 18 (1994), S. 9-13 
    ISSN: 1573-2630
    Keywords: biocompatibility ; fibrosis ; lens decentration ; lens position ; small incision cataract surgery ; small optic PMMA IOLs ; Soemmering's ring
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In this prospective study the clinical results using three different small optic IOLs are presented. The best results were achieved in those cases with an anterior capsule rim overlapping the entire optic periphery. In those cases with sulcus fixation, haptic in/out and optic in/out positions a higher percentage of capsule flbrosis (Soemmering's rings) was documented (sulcus fixation: 100%, haptic in/out position: 75%, optic in/out position: 65.5%, bag: 7.3%). The fibrosis developed because of contact between the anterior and the posterior capsule leaf. These cases also showed decentrations of the intraocular lense (IOL) more often (sulcus fixation: 50%, haptic in/out position: 75%, optic in/out position: 34.5%, bag: 31.7%). Only one patient was disturbed by glare and halo phenomenons. Cellular reactions on the lens surface were moderate in most cases. Differences specific to lens type were found between the three IOLs implanted. The clinical results were comparable to the results of other comprehensive IOL studies. Under certain indication small optic IOLs represent an alternative to flexible implants for small incision surgery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 80 (1992), S. 301-307 
    ISSN: 1573-2622
    Keywords: Carbachol ; intraocular pressure ; polyHema intraocular lens ; small-incision cataract ; surgery ; sodium hyaluronate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Sixty patients, who underwent phacoemulsification and implantation of a folded polyHema intraocular lens were assigned to two groups. Following wound closure 0.5 ml of 0.01% carbachol or balanced salt solution was instilled into the anterior chamber. Healon was used in all eyes but evacuated from the capsular bag behind the intraocular lens and the anterior chamber. Intraocular pressure was measured the day before as well as 6 and 18 hours postoperatively. At 6 hours the mean change of intraocular pressure from baseline was ±2.8 ± 5.3 mmHg in the carbachol group compared with +4.7 ± 8.0 mmHg in the BSS group (p 〈 0.0001). At 18 hours the mean change from baseline was ±3.0 ± 4.6 mmHg in the treatment group and +2.3 ± 8.5 in the control group (p 〈 0.0001). Intraocular pressure exceeding 25 mmHg at 6 hours was observed in 8 (27%) eyes of the control group but none of the treatment group. At 18 hours 4 (13%) eyes of the control group and 1 (3%) of the carbachol group still had an increase of intraocular pressure. Summarizing our results we conclude that the effect of Healon on the postoperative intraocular pressure is successfully counteracted by its aspiration from the capsular bag and the anterior chamber, especially when carbachol is used for intraoperative miosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...