    European journal of applied physiology 65 (1992), S. 37-42 
    ISSN: 1439-6327
    Keywords: Alveolar-arterialPO2 difference ; Pulmonary gas exchange ; VO2max ; Hypoxia ; Hyperoxia
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary These experiments examined the exercise-induced changes in pulmonary gas exchange in elite endurance athletes and tested the hypothesis that an inadequate hyperventilatory response might explain the large intersubject variability in arterial partial pressure of oxygen (P a02) during heavy exercise in this population. Twelve highly trained endurance cyclists [maximum oxygen consumption (VO2max) range = 65-77 ml·kg−1·min−1] performed a normoxic graded exercise test on a cycle ergometer toVO2max at sea level. During incremental exercise atVO2max 5 of the 12 subjects had ideal alveolar to arterial P02 gradients (P A-aO2) of above 5 kPa (range 5-5.7) and a decline from restingP aO2 (ΔP aO2) 2.4 kPa or above (range 2.4-2.7). In contrast, 4 subjects had a maximal exercise (P A-aO2) of 4.0-4.3 kPa with ΔP aO2 of 0.4-1.3 kPa while the remaining 3 subjects hadP A-aO2 of 4.3-5 kPa with ΔP aO2 between 1.7 and 2.0 kPa. The correlation between PAO2 andP aO2 atVO2max was 0.17. Further, the correlation between the ratio of ventilation to oxygen consumption VSP aO2 and arterial partial pressure of carbon dioxide VSP aO2 atVO2max was 0.17 and 0.34, respectively. These experiments demonstrate that heavy exercise results in significantly compromised pulmonary gas exchange in approximately 40% of the elite endurance athletes studied. These data do not support the hypothesis that the principal mechanism to explain this gas exchange failure is an inadequate hyperventilatory response.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1573-6865
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The purpose of this investigation was to examine critically the validity of a computerized quantitative microphotometric histochemical technique for the determination of succinate dehydrogenase (SDH) activity in skeletal muscle fibres. Sections from the anterior costal diaphragm were removed from Fischer-344 rats (n = 12) and assayed histochemically to determine SDH activity. The SDH activity in individual muscle fibres was computed using a computerized microphotometric histochemical technique which involves measurement of the optical density of deposited diformazan derived from nitroblue tetrazolium within the fibres. To validate the histochemical technique, whole muscle SDH activities were calculated from the histochemical procedure and were compared to SDH activities determined from whole muscle homogenates via a standard quantitative biochemical assay. The mean within-day variability of the computerized microphotometric histochemical technique of determining SDH activity was 6% (range = 0.5–10.9%) for an area containing ~50 fibres and 6.1% (range = 1.05–14.9%) for an individual muscle fibre. Similarly, the mean between-day variability of the microphotometric histochemical technique of determining SDH activity was 5.9% (range = 2.6–13.9%) for an area containing ~50 fibres and 6.6% (range = 2.2–13.9%) for an individual muscle fibre. The inter-class correlation coefficient between biochemically determined SDH activity and histochemically determined SDH activity was r = 0.83 (p 〈 0.05). Collectively, these data demonstrate that the quantitative histochemical technique of Blanco et al. (1988) is both valid and reliable in the determination of SDH activity in skeletal muscle fibres.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1439-6327
    Keywords: Plasma volume ; Fluid replacement ; Prolonged exercise ; Hypovolemia ; Hydration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Previous experiments have demonstrated that consumption of a glucose polymer-electrolyte (GP-E) beverage is superior to water in minimizing exercise-induced decreases in plasma volume (PV). We tested the hypothesis that elevated plasma concentrations of vasopressin and/or aldosterone above that seen with water ingestion may explain this observation. Six trained cyclists performed 115 min of constant-load exercise (approximately 65% of maximal oxygen consumption) on a cycle ergometer on two occasions with 7 days separating experiments. Ambient conditions were maintained relatively constant for both exercise tests (29–30° C; 58–66% relative humidity). During each experiment, subjects consumed 400 ml of one of the following beverages 20 min prior to exercise and 275 ml immediately prior to and every 15 min during exercise: (1) distilled water or (2) GP-E drink contents = 7% carbohydrate (glucose polymers and fructose; 9 mmol·1−1 sodium; 5 mmol·1−1 potassium; osmolality 250 mosmol·1−1). No significant difference (P〉0.05) existed in mean skin temperature, rectal temperature, oxygen consumption, carbon dioxide production or the respiratory exchange ratio between treatments. Further, no significant differences existed in plasma osmolality and plasma concentrations of sodium, potassium, chloride or magnesium between treatments. Plasma volume was better maintained (P〈0.05) in the GP-E trial at 90 and 120 min of exercise when compared to the water treatment. No differences existed in plasma levels of vasopressin or aldosterone between treatments at any measurement period. Further, the correlation coefficients between plasma concentrations of vasopressin and aldosterone and change in PV during exercise were 0.42 (P〈0.05) and 0.16 (P〉0.05), respectively. Therefore, although these experiments support the notion that a GP-E beverage is superior to water in minimizing exercise-induced disturbances in PV during prolonged exercise, the mechanism to explain this observation is not due to differences in plasma concentrations of vasopressin or aldosterone alone.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1439-6327
    Keywords: Electrolytes ; Fluid balance ; Glucose ; Exercise metabolism ; Blood pH
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The purpose of these experiments was to examine the influence of various fluid replacement drinks on exercise-induced disturbances in homeostasis during heavy exercise. Nine trained cyclists performed constant load exercise on a cycle ergometer to fatigue on three occasions with 1-week separating experiments. The work rate was set initially at ∼ 85% of $$\dot V_{o_{2{\text{ }}max} } $$ (range 82–88%) with fatigue being defined as a 10% decline in power output below the initial value. During each experiment subjects consumed one of the following three beverages prior to and every 15 min during exercise: (1) non-electrolyte placebo (NEP; 31 mosmol · kg−1); (2) glucose polymer drink containing electrolytes (GP; 7% CHO, 231 mosmol · kg−1), and (3) electrolyte placebo drink without carbohydrate (EP; 48 mosmol · kg−1). Both the GP and EP beverage contained sodium citrate/citric acid (C) as a flavoring agent while C was not contained in the NEP drink. Although seven of nine subjects worked longer during the GP and EP treatment when compared with the NEP trial, the difference was not significant (P〉0.05). No differences (P〉0.05) existed between the GP and EP treatments in performance time. Exercise changes in rectal temperature, heart rate, Δ % plasma volume and plasma concentrations of total protein, free fatty acids, glucose, lactate, potassium, chloride, calcium, and sodium did not differ (P〉0.05) between trials. In contrast, blood hydrogen ion concentration [H+] was significantly lower (P〈0.05) at 30 min of exercise during the GP and EP treatment when compared with the NEP run. These data provide evidence that electrolyte drinks do not minimize exercise-induced disturbances in blood-electrolyte concentrations during heavy execrcise when compared with nonelectrolyte drinks; however, these results suggest that fluid replacement beverages containing buffers (i.e. C) and/or electrolytes may minimize blood alterations in [H+] during intense exercise. Additional research is required to determine if the buffering influence of these beverages has an ergogenic benefit during heavy exercise.