Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1990-1994  (2)
  • 1
    ISSN: 1432-1238
    Schlagwort(e): Subcutaneous oxygens tension ; Transcutaneous oxygen tension ; Tissue perfusion ; PEEP ; Cardiac output ; Oxygen delivery
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective To compare subcutaneous (PscO2) and transcutaneous (PtcO2) oxygen tension measurements in relation to hemodynamic variables at different levels of PEEP, and to evaluate the usefulness of these measurements as monitors of peripheral tissue perfusion. Design Prospective trial. Setting Intensive care unit in a university hospital. Patients Seven patients with gastric cancer who where undergoing total gastrectomy. Interventions Silicone catheter was placed in the upper arm and transcutaneous oxygen monitor was placed on the upper part of the chest. A pulmonary artery catheter was placed in the right pulmonary artery. Measurements and results PscO2 and PtcO2 together with hemodynamic variables were measured at different levels of PEEP. Progressive increase of PEEP reduced cardiac index (CI) (p〈0.05) with a concomitant decrease of PscO2 (p〈0.05) and oxygen delivery (DO2) (p〈0.05). Changes in PtcO2 parallelled changes in arterial oxygen tension (PaO2), but no correlation was found between PtcO2, CI and DO2. Conclusion PscO2 is a sensitive indicator of subcutaneous tissue perfusion, which can be used to identify the PEEP level, with optimum peripheral perfusion. PscO2 seems to be a more reliable indicafor of tissue perfusion than PtcO2.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    European journal of clinical pharmacology 45 (1993), S. 147-150 
    ISSN: 1432-1041
    Schlagwort(e): Terbutaline ; Bambuterol ; Cerebrospinal fluid ; plasma ; human ; adverse effects®
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie , Medizin
    Notizen: Summary Concentrations in cerebrospinal fluid (CSF) and plasma of bambuterol and its active metabolite, the β2-adrenoceptor agonist terbutaline, were measured in man after four once-daily doses of 30 mg bambuterol hydrochloride (Bambec®). Nine patients scheduled for orthopaedic surgery under spinal anaesthesia completed the study. The concentrations of both substances were much lower in CSF than in plasma, the ratio CSF/plasma being 0.09 for bambuterol and 0.19 for terbutaline, at apparent steady state. While the rank order of the ratios was expected from the fractions of unbound bambuterol and terbutaline in plasma, their absolute values were only about 1/6 (bambuterol) and 1/4 (terbutaline) of those predicted from diffusion equilibria between plasma and CSF. Thus, the rates of transport of bambuterol and terbutaline from plasma into the central nervous system appear to be slow relative to transport out of the system, e.g. by outflow of CSF. The findings are in agreement with animal experiments and suggest that bambuterol and terbutaline are less likely than lipophilic β2-adrenoceptor agonists to interact with central receptors.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...