Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 43 (1994), S. 26-29 
    ISSN: 1432-055X
    Keywords: Schlüsselwörter: Spinalanästhesie – Säuglinge – Adrenalin – Bupivacain – Wirkdauer ; Key words: Spinal anaesthesia – Pre-term infant – Epinephrine – Bupivacaine – Duration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract. The duration of spinal anaesthesia in infants is short compared to adult patients. When tetracaine is used, the addition of epinephrine significantly prolongs the duration. For bupivacaine, however, the influence of epinephrine on the duration is not clear. We investigated the effects of epinephrine 1: 200 000 added to bupivacaine 0.5% on duration and haemodynamics. Patients and Methods. Ten former pre-term infants with postnatal respiratory problems, scheduled for bilateral inguinal hernia repair, were enrolled in the study after informed parental consent had been obtained. The infants were fasted at least 4 h prior to surgery. If they did not receive i.v. infusions before surgery, a bolus of 10 ml/kg Ringer's acetate was injected after inserting the i.v. cannula, followed by a continuous infusion of 8 ml/kg 2/3 N NaCl with 5% dextrose. Spinal anaesthesia was performed in a sitting position with 0.6 ml bupivacaine 0.5%. Five patients received plain bupivacaine (group I) and five bupivacaine with epinephrine 1: 200 000 (group II). Heart rate registered by ECG and non-invasive blood pressure were recorded prior to positioning the baby for lumbar puncture and 2, 5, 10, and 20 min after injection of bupivacaine. The duration of spinal anaesthesia was defined as the time from injection to the time when the first movements of the legs were observed after stimulation. For testing statistical differences the U test was used between the groups and the Wilcoxon and Wilcox test within the groups. Results (expressed as median and range). Additional epinephrine significantly prolonged the duration of spinal anaesthesia (group II: 95 min [60 – 120] vs group I: 50 min [37 – 85]). Haemodynamic parameters did not differ at any time between or within the groups. In group I, one infant had high spinal anaesthesia with impaired respiration but without cardiovascular effects; after 10 min of assisted ventilation by mask, sufficient respiration as judged by pulse oximetry and clinical observation had returned. The duration of spinal anaesthesia in this child was 60 min. Conclusions. Epinephrine 1: 200 000 significantly prolongs the duration of spinal anaesthesia in former preterm infants. Haemodynamic parameters in this age group remain unchanged during spinal anaesthesia and are not influenced by the addition of epinephrine.
    Notes: Zusammenfassung. Bei 10 ehemaligen Frühgeborenen mit einem Gestationsalter zwischen 38 und 48 Wochen am Operationstag und einem Gewicht zwischen 2,10 und 3,22 kg, die postpartal respiratorische Adaptationsstörungen aufwiesen, wurde nach elterlichem Einverständnis eine Spinalanästhesie mit 0,6 ml Bupivacain 0,5% für eine Leistenhernienoperation durchgeführt. Jeweils 5 Patienten erhielten Bupivacain ohne Adrenalinzusatz (Gruppe I) bzw. mit Adrenalin 1: 200 000=5 µg/ml (Gruppe II). Die Wirkdauer wurde definiert als Zeit von der Injektion bis zur ersten Bewegung der Beine: Die über das EKG registrierte Herzfrequenz und die oszillometrisch gemessenen Blutdruckwerte wurden vor Lagerung zur Lumbalpunktion sowie 2, 5, 10 und 20 min nach der Injektion des Lokalanästhetikums erhoben. Die Wirkdauer einer Spinalanästhesie war im Median in der Gruppe II mit 95 min (60 – 120) signifikant länger als in der Gruppe I mit 50 min (37 – 85). Keine signifikanten Unterschiede zeigten sich bei Herzfrequenz und Blutdruckwerten – weder zwischen den Gruppen noch im zeitlichen Verlauf einer Gruppe.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 67 (1990), S. 4456-4458 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The spin dependence of L2,3 absorption in 5d atoms oriented in a ferromagnetic matrix contains information on the spin density of the empty d-projected states of the absorbing atom. Spin-dependent absorption spectroscopy using circularly polarized synchrotron radiation was applied to study the polarization of the Pt atoms in the binary alloy Co50Pt50 and Pt/Co layered structures, which are promising candidates for magneto-optical recording. The spin-dependent absorption signals for vapor-deposited 250(4 A(ring) Co+18 A(ring) Pt) and 250(6 A(ring) Co+18 A(ring) Pt) multilayers indicate a ferromagnetic coupling on Pt and Co atoms with a significant Pt polarization. This is reduced on average by about 60% with respect to the Pt polarization in the Co50Pt50 alloy. The experimental results are discussed on the basis of spin-polarized band-structure calculations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International journal of flexible manufacturing systems 4 (1992), S. 129-158 
    ISSN: 1572-9370
    Keywords: robot ; cell ; machine tending ; recursion model ; transient operations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Abstract This article presents an efficient algorithm for applying the recursion modeling approach to describe the transient operation of cellular production/assembly systems that incorporate features such as finite buffers, job-shop routing, lot sequencing, and material handling. Tests evaluate the approximation method relative to number of machines at a station, capacity of input/output buffers, degree of balance among station processing times, and sequencing rule. Furthermore, the method is demonstrated in application to a hypothetical industrial setting that involves the assembly of electronic circuit cards in a facility composed of several cells. All tests indicate that the method gives accurate estimates of transient performance within reasonable runtime. In comparison with earlier recursion models, this research incorporates a number of new features (see list above), improves the accuracy of approximation, and facilitates implementation with a new, more efficient algorithm.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Queueing systems 17 (1994), S. 471-490 
    ISSN: 1572-9443
    Keywords: Kitting ; assembly ; Markov renewal process ; double-ended queue
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science
    Notes: Abstract In small-lot, multi-product, multi-level assembly systems, kitting (or accumulating) components required for assembly plays a crucial role in determining system performance, especially when the system operates in a stochastic environment. This paper analyzes the kitting process of a stochastic assembly system, treating it as an assembly-like queue. If components arrive according to Poisson processes, we show that the output stream departing the kitting operation is a Markov renewal process. The distribution of time between kit completions is also derived. Under the special condition of identical component arrival streams having the same Poisson parameter, we show that the output stream of kits approximates a Poisson process with parameter equal to that of the input stream. This approximately decouples assembly from kitting, allowing the assembly operation to be analyzed separately.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Cell Biochemistry and Function 10 (1992), S. 159-165 
    ISSN: 0263-6484
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...