Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (7)
  • 1985-1989  (2)
  • 1935-1939  (7)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Analytical chemistry 63 (1991), S. 1638-1643 
    ISSN: 1520-6882
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 70 (1991), S. 2926-2938 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Experiments are described in which a high-purity, high-power (0.15 TW, 1 MeV) proton beam is generated from an ion source consisting of H2 gas frozen onto a liquid-helium-cooled copper anode at 4.2 K in a series-field-coil extraction diode on the 0.7 TW HydraMITE-II accelerator. Peak anode proton current densities of 2 kA/cm2 were measured. This current density is a factor of 100 higher than those obtained in previous liquid-helium-cooled cryogenic diode experiments on small accelerators and is in the range required for high-power ion beam applications. Thomson parabola, Faraday cup, and carbon activation measurements indicate an ion beam proton fraction close to 100% for the cryogenic source, compared to 50–70% for the standard hydrocarbon anode tested. The cryogenic proton source is believed to consist of no more than a few monolayers of molecular hydrogen. The hydrogen-coated cryogenic anode shows a faster initial anode turn-on than other materials. However, source-limited emission from the thin hydrogen layer results in a somewhat longer current risetime, reduced ion diode efficiency, lower proton current enhancement over the Child–Langmuir limit, and a proton spectrum of lower average energy than for the hydrocarbon anode. Techniques to overcome these limitations are discussed. Cryogenic ion sources consisting of frozen N2, CH4, and Ne have also been studied. In each case, high intensity beams consisting predominantly of components of the refrigerated gas were produced.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 68 (1990), S. 4917-4928 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Accurate modeling of load behavior in Z-pinch plasma radiation sources driven by high-current generators requires the measurement of fast-rise-time multimegampere currents close to the load. Conventional current diagnostics mounted in inductive cavities (such as B-dot loops and Rogowski coils) fail at small radius because of electrical breakdown produced by high dI/dt. In this paper, we describe the use of large-signal, nanosecond-time-resolution lithium niobate piezoelectric stress gauges to directly measure the magnetic pressure B2/2μ0=μ0I2/8π2r2 generated at radius r by a current I flowing in a radial transmission line. Current measurements have been performed at radius r=2.54×10−2 m on Sandia National Laboratories' Proto-II (10 TW) and SATURN (30 TW) gas puff Z-pinch experiments with maximum currents of 10.1 MA and dI/dt to 2.1×1014 A/s. Comparisons with Faraday rotation and B-dot current diagnostic measurements at large radius are presented. Bremsstrahlung noise problems unique to the SATURN gas puff source are discussed. For a Y-cut lithium niobate stress gauge on a pure tungsten electrode, current densities up to I/2πr=78 MA/m can be measured before the electrode yield strength and the piezoelectric operating stress limit are exceeded. Above the Hugoniot elastic limit of the electrode material, the dynamic range and accuracy of the diagnostic are greatly reduced, but it appears that the technique can be extended to higher current densities using an X-cut quartz piezoelectric element and a tungsten-sapphire electrode impedance stack.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Industrial & engineering chemistry 29 (1937), S. 980-984 
    ISSN: 1520-5045
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 58 (1936), S. 1504-1505 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Nutrition 9 (1989), S. 303-345 
    ISSN: 0199-9885
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 57 (1935), S. 229-230 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 59 (1937), S. 216-217 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 58 (1936), S. 1063-1064 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Plant pathology 35 (1986), S. 0 
    ISSN: 1365-3059
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: At Long Ashton Research Station serious outbreaks of fireblight (caused by Erwinia amylovora) occurred on apples in 1978, 1980 and 1982. and on pears in 1979, Mid-season and late-flowering cider apple cultivars were particularly affected. On cider apple, outbreaks were associated with years of profuse blossom coinciding with unusually warm temperatures during bloom. Spread of infection between hosts, including hawthorn and cotoneaster, was undoubtedly important. These and other factors underlying the outbreaks are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...