Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (11)
  • 1980-1984  (3)
  • 1
    ISSN: 1089-7666
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Hot electrons have been produced by second harmonic electron-cyclotron resonance heating in axisymmetric end mirrors of the tandem mirror GAMMA10 [Phys. Rev. Lett. 55, 939 (1985)] with an on-axis density fraction reaching 80% and temperature of 25–50 keV, satisfying theoretically required conditions for the formation of thermal barriers. The successful control of the electron temperature may be attributed to the relativistic detuning of the second harmonic resonance for localized microwave power absorption. The time evolutions of relevant parameters are studied with extensive diagnostics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Using undulator radiation from 2 to 8 keV, quantum efficiencies [QE(E)] of gold photocathodes, microchannel plates (MCP), and silicon surface barrier (SSB) detectors have been investigated. For the gold photocathodes, the detailed structure of QE(E) near the M absorption edges has been presented. Also, the secondary electron conversion efficiency of gold has been calculated using the mass absorption coefficient given by a relativistic Hartree–Slater model and by the semiempirical values of Henke et al., respectively. Extended x-ray absorption fine structure (EXAFS) has been observed in the secondary electron current of the gold photocathode as well as in the detection current responses of an MCP and of an SSB detector. Furthermore, the new findings adding to our recent paper1 have been summarized as follows: (i) EXAFS above the Si-K edge in the MCP response depends on photon incident angles, and (ii) a little upshift of the starting point energy of EXAFS in the MCP response is observed. These detailed characteristics and their interpretation are described in the following: (i) The current responses of the MCP are obtained as a function of the incident x-ray energy for θ=13° (the bias angle of the MCP), and 40° by using a gold-monitor current. Here, θ denotes the incident angle of the photons to the channel. The data for θ=40° show a smaller jump near the Si-K edge as compared with the data for θ=13°.This is explained as follows: The incident photons for θ=13° are irradiated to and absorbed in the MCP ingredient of SiO2, while photons for θ=40° are incident to the electrode region. (The depth of the electrode coating is more than 10 μm from the MCP surface, while the photons are absorbed at less than 8 μm from the surface for θ=40°.) Thus, the data for θ=40° strongly reflect the characteristics of the electrode, but not of SiO2. The data for several values of θ consistently indicate that the height of this jump becomes smaller with increasing θ. (ii) The observed upshift of the starting point energy of EXAFS in the MCP response presents a contrast to EXAFS in the SSB detector response, in which upshift is not observed. This upshift is ascribed to the molecular structure of SiO2 (the chemical shift); that is, some valence electrons are removed from the Si atoms due to the oxidation (i.e., SiO2). Thus, the screening effects of the valence electrons on the core electron-nucleus attraction are reduced. This results in the shift of binding energy towards the higher-energy side. On the other hand, EXAFS in the SSB detector response reflects the characteristics of Si.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 60 (1989), S. 368-371 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The characteristics of microchannel plates (MCPs) for detection of x rays have been investigated using synchrotron radiation in the energy range from 1.8 to 8 keV. The current response curve of MCPs is measured with approximately continuous x-ray energy variation, which is added to the previous data [T. Kondoh et al., Rev. Sci. Instrum. 59, 252 (1988)]. It is confirmed that there is a minimum in the current response at the x-ray energy of about 4 keV. The precise current response curve has been completed for the wide x-ray energy range from 0.6 to 20 keV. A transition in the incident angle dependence of current response is found from the feature based on single cylindrical photocathode model for soft x rays to that based on multiple channel activation due to the penetration of x rays through channel walls for hard x rays. In the current response of MCPs the structure similar to that in EXAFS is observed near the Si K edge.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 59 (1988), S. 1515-1517 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: In order to study impurity behavior on the JT-60 plasma, a spectroscopic diagnostic system, which is capable of measuring many spectra of impurity ions and their spatial distributions simultaneously, has been developed. This system consists of interchangeable unit-type spectrographs which have different lines of sight. Four types of grazing incidence spectrographs are prepared as unit-type spectrographs. These spectrographs cover the nominal wavelength regions 0.5–5, 0.5–50, 2.0–50, and 50–122 nm, respectively, and have holographic gratings with flat focal fields. Image-intensified 1024- or 512-channel photodiode arrays are used as detectors for all spectrographs. Four unit-type spectrographs are used for observing the main plasma, and two unit-type spectrographs are used for observing the plasma near the null point of the diverted discharge. One of these spectrographs has been calibrated absolutely in the wavelength region 27.5–120 nm using synchrotron radiation from the Photon Factory (National Laboratory for High Energy Physics).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The quantum efficiency of gold photocathodes has been investigated by using synchrotron radiation from 2–8 keV; in particular its detailed structure near the M absorption edge region is obtained. The secondary electron conversion efficiency of gold has been calculated by using the mass absorption coefficient given by a relativistic Hartree-Slater model and by the semiempirical values of Henke et al., respectively. These data are compared with the published data at some discrete energies, and we add several new data points, especially for the gold M edge region (2–4 keV). X-ray absorption fine structure (EXAFS) has been observed in the secondary electron current of the gold photocathode as well as in the detection current responses of a microchannel plate and a silicon surface barrier detector.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 59 (1988), S. 252-255 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The characteristics of microchannel plates (MCPs) for detection of x rays have been investigated using synchrotron radiation in the energy ranges from 0.6 to 2.0 keV and from 5 to 20 keV. Microchannel plates are operated under the condition of an unsaturated pulse-height distribution mode. The current response curve of MCPs is measured continuously with x-ray energy variation for the first time. The experimental result of some discontinuous jumps in the response is obtained at the energies corresponding to the absorption edge of the MCP materials. In the low-energy range (hν〈2 keV), the dependence of the current response to the incident angle of x rays to the channel axis θ is measured to be proportional to cot θ, which is interpreted by the x-ray absorption near the surface of MCP channel wall. While, in the high-energy range (hν〉5 keV), a weak dependence on θ is observed, and is attributed mainly to the penetration of x rays through multiple channels.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A time-of-flight type neutral particle energy analyzer can discriminate between neutral particle loss and radiation loss from a plasma by use of the difference between their times of flight. The energy distribution of hydrogen atoms which are emitted from the plasma can be estimated from the time evolution of the detector signal. The energy distribution of radiated photons can be obtained by using several filters which transmit different ranges of the photon energy. With this method the ratio of the particle and radiation losses emitted from the same plasma volume and within the same detector solid angle can be obtained.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Current response characteristics of microchannel plates (MCPs) x-ray detectors have been measured in a wide energy range from 0.6 to 82 keV using synchrotron radiation. In the current response curve with continuous photon energy, some discontinuities have been observed to correspond to absorption edges of elements which are the constituents of MCP glass and electrode materials (Si, Pb, Ba, and Fe). The dependence of the MCP response on the incident angle of x rays to the channel axis, θ, is also investigated. The characteristics change from the cot θ dependence for soft x rays (hν〈4 keV) to the sec θ one for hard x rays (hν〉60 keV). These results could provide guidelines on the design of x-ray diagnostic instruments using MCPs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Scandinavian journal of immunology 20 (1984), S. 0 
    ISSN: 1365-3083
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Pregnant mice were stimulated by heterologous erythrocyte and protein antigen, and the active immune responses of their offspring as measured by plaque-forming cells (PFC) were investigated. In offspring derived from mothers immunized by a suitable amount of T-dependent antigen, clear-cut suppression of development of specific PFC in spleen was observed over a significant period after delivery. The mechanism of this suppression was investigated, and the following results were obtained. When the heterologous erythrocyte was used as antigen, the more the specific PFC developed in the mother spleen, the stronger the suppression of PFC observed in their offspring. However, it is worthy of note that passive administration of antibody to pregnant mice did not induce suppression in their young. In case of the protein antigen ovalbumin (OVA), pregnant mice had to be injected with a suitable amount of antigen, along with aluminium hydroxide, for either primary or secondary stimulus to induce the suppression of specific PFC in their offspring. Soluble OVA administered to pregnant mice was not effective for inducing suppression in the offspring. Based on these results, some possible mechanisms are discussed concerning specific PFC suppression in the offspring when pregnant mice are stimulated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-0533
    Keywords: Familial juvenile Alzheimer's disease ; Multisystemic degeneration ; White matter degeneration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary An autopsy case of familial juvenile Alzheimer's disease with extensive involvement of the subcortical gray and white matters is reported. A 33-year-old woman showed a progressive dementia and died of cardiac failure at the age of 45. Neurological examination disclosed choreatic movements, myoclonus, rigidity, and generalized convulsion. Gross inspection of the brain showed a diffuse cerebral atrophy and marked degenerations of both the subcortical gray and white matters. Microscopically, numerous and extensive argyrophilic changes such as senile plaques, neurofibrillary tangles, and granulovacuolar degenerations were observed in the brain. The present case was characterized by a severe neuronal loss in the basal ganglia, substantia nigra, dentate nucleus, and thalamus as well as a marked myelin loss and axonal damage in the cerebral white matter. This case suggested a combination of multisystemic degeneration and primary degeneration of the cerebral white matter. The pathological similarity of this case to Creutzfeldt-Jakob disease and Pick's disease is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...