Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (1)
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    X-Ray Spectrometry 15 (1986), S. 23-27 
    ISSN: 0049-8246
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: An increase of an order of magnitude in the precision of the balanced filters method is achieved by using a low-power x-ray tube and measuring the ionization current, without increasing the measurement time. A simultaneous change of excitation and detection is essential: the measurement of the ionization current makes possible a dead-time free detection of the high intensities excited by the x-ray tube, and leads to a decrease in the statistical error. The standard deviations obtained with a portable analyser utilizing this method in the determination of the Cr and Mn contents of low-alloy steels in the concentration range 0-1.5% are 0.02 and 0.03%, respectively.
    Additional Material: 4 Ill.