Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (3)
Material
Years
  • 1985-1989  (3)
Year
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 59 (1988), S. 2260-2264 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Eight triaxial Blumleins have been stacked in series at one end while being synchronously commuted at the other end with a single hydrogen thyratron. Significant voltage gain has been maintained in the stack for periods of the order of 20 ns. Having no other switching elements, operation has been possible at repetition rates to 100 Hz. An x-ray diode has been matched to this pulse power source, making possible the emission of an average bremsstrahlung dose of 5.8 R/s from a sequence of 20-ns pulses. In less than 4 min of operation at 100 Hz, a dose of 1 kR could have been delivered to a target sample. When operated at 50-kV charging voltage, spectral measurements show the output to be a true continuum, peaking at intensities in excess of 2×108 keV/keV/shot and containing useful intensities of photons having energies of 150 keV.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 58 (1987), S. 2103-2109 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Described here is the scaling of a repetitively pulsed, flash x-ray source to yield 140-mW average power in 15-ns pulses of radiation near 1 A(ring). Interchangeability of discharge anodes has provided for a significant fraction of the output to be extracted in the K lines of Cu, Mo, Nb, and Ag. In less than 1 min of experimental time, a peak spectral density is radiated that exceeds 1×1018 keV/keV. For some applications this device can offer a tabletop alternative to laser plasma x rays and to synchrotron radiation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 863-865 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Described here is a repetitively pulsed, flash x-ray source capable of emitting 35-mW average power in 6-ns pulses of radiation near 1.5 A. From this device a significant fraction of the output is represented by the K lines of copper, so that in less than 1 min of experimental time a peak spectral density is radiated that exceeds 2×1017 keV/keV. For some applications this device can offer a laboratory alternative to laser plasma x rays or synchrotron radiation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...