Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (3)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of food quality 8 (1985), S. 0 
    ISSN: 1745-4557
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Subdivided samples of ground beef, pork sausage, and wieners were oven-dried at 102°C or extracted with diethyl ether at various time intervals from 1/4 to 8 h. Each moisture and fat extraction period correlated well with the standard 8 h analysis, although less variation tended to occur after 4 h of drying or extraction time. Results from reduced analysis time for moisture and fat determination were closely associated with the standard 8 h values and each other. These data suggest that modified moisture and fat determination methods which were evaluated gave suitably accurate and precise results for routine analyses use for quality control.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of food quality 8 (1985), S. 0 
    ISSN: 1745-4557
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: Four moisture and four fat determination methods requiring from 5 min to 12 h were performed on 664 ground beef samples to compare accuracy and precision of rapid fat and moisture determinations to the Association of Official Analytical Chemists (AOAC) procedures. The modified Babcock results were closer to the official ether extraction method than those obtained from the Banco and Univex methods. Moisturefuge moisture determinations were more highly correlated with AOAC percentages than either the Toluene or Ohaus methods. Correlations among moisture and fat determination methods studied with official results were 0.90 or higher and none of the fat and moisture values differed significantly from those using AOAC methods. These data suggest the modified rapid moisture and fat determination methods evaluated have adequate accuracy and precision for reliable control and analyses use.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1745-4557
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Process Engineering, Biotechnology, Nutrition Technology
    Notes: As marbling increased from“practically devoid” to“moderately abundant”, loin steaks were more palatable (P〈0.05) about 2/3 of the time, round steaks were more palatable (P〈0.05) about 1/8 of the time, and loin steaks were more likely to be assigned high (≥6.00) panel ratings and to have low (≤3.63 kg) shear values. However, increases in marbling from“slight” to“moderately abundant” (A maturity) and from“small” to“moderately abundant” (A+B maturity) had little or no efect on percentage incidence of loin or round steaks with panel ratings ≤2.99 or ≥4.00, or with shear values ≥6.35 kg or ≤4.99 kg. Differences in marbling explained about 33% (loin) and 7% (top round) of the variation in overall palatability ratings in A, B, C, and A+B maturity carcasses.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...