Abstract The reliability of two solvent extraction techniques for the determination of Pu oxidation states in solution was tested with low-ionic-strength solutions and with high-Na and high-Mg brines that contained Pu concentrations sufficient for spectrophotometric analysis. One procedure only differentiates between reduced Pu [Pu(III) and Pu(IV)] and oxidized Pu [Pu(V) and Pu(VI)], whereas the second procedure was designed to differentiate between Pu(IV), Pu(V), and Pu(VI) in solution. Both procedures successfully differentiated between oxidized and reduced Pu in both dilute solutions and brines when tested with samples that contained only the Pu(IV), Pu(V), or Pu(VI) oxidation states. However, when the second solvent extraction procedure, which differentiates between Pu(V) and Pu(VI), was employed for solutions that did not contain a strong oxidant to maintain the Pu(VI) oxidation state, significant quantities of Pu(VI) were reduced to Pu(V) during extraction, indicating that accurate quantification of Pu(V) and Pu(VI) is not possible with this procedure.