Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1995-1999  (2)
  • 1980-1984  (3)
  • 1
    Electronic Resource
    Electronic Resource
    Chester : International Union of Crystallography (IUCr)
    Journal of synchrotron radiation 5 (1998), S. 443-444 
    ISSN: 1600-5775
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: The high-brilliance synchrotron radiation source BESSY II will provide space for the installation of 14 insertion devices. At the time of writing (July 1997), eight insertion devices are funded. The first light for use by scientists will be available in January 1999. The undulators are designed for a scanning operation in parallel with the monochromator. This modus requires tight tolerances concerning the drive system. The first insertion device to be installed, a U-49 undulator, has been assembled and magnetically measured. The r.m.s. phase error is 2°. An endpole configuration using coils with less than 64 amp-turns makes the angular kick smaller than ±3 µrad over a gap range 15–50 mm.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 308 (1982), S. 121-131 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The elastic and inelastic scattering of12C on12C has been measured in the angular range between 2.8° and 70.4° in the c.m. system atE Lab =300 MeV. Optical model calculations have been performed with Woods-Saxon and folded potentials, the ground state and the first 2+-state were coupled in the calculations. The large cross sections of the elastic scattering at large angles is related to the nuclear rainbow scattering, which is centered at about 56°. This requires a potential depth of 100 MeV at a distance of 3 fm, the fit to the data is sensitive down to this region. The calculations with the folded potential show a better agreement with the data than those with the Woods-Saxon shape. The total reaction cross section of 1,420 mb, obtained from the optical model analysis, corresponds to the geometrical value; no transparency is observed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 314 (1983), S. 143-147 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract For the reaction 290 MeV20Ne+197Au the number of neutrons emitted in coincidence withα-particles is used to discriminate between two equally important but qualitatively different mechanisms for the emission of fastα-particles. They are connected with low and high inelasticity, respectively, and the resultingα-particles differ in mean velocity and velocity distribution.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 3 (1998), S. 387-396 
    ISSN: 1434-6036
    Keywords: PACS. 73.23.Ad Ballistic transport - 03.65.Sq Semiclassical theories and applications
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: We study the influence of a tunnel barrier on the quantum transport through a circular cavity. Our analysis in terms of classical trajectories shows that the semiclassical approaches developed for ballistic transport can be adapted to deal with the case where tunneling is present. Peaks in the Fourier transform of the energy-dependent transmission and reflection spectra exhibit a nonmonotonic behaviour as a function of the barrier height in the quantum mechanical numerical calculations. Semiclassical analysis provides a simple qualitative explanation of this behaviour, as well as a quantitative agreement with the exact calculations. The experimental relevance of the classical trajectories in mesoscopic and microwave systems is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Using a Q3D magnetic spectrometer the elastic and inelastic scattering of12C on88Sr and the neutron pick-up (12C,13C) has been studied. The spin alignment of the inelastically excited 2+ state of12C (4.43 MeV) has been deduced from the line shapes broadened by theγ-decay in flight. Thus for eachm-substate a full angular distribution was obtained. Them=1 substate shows a shifted interference minimum, which is explained by the different strength of the Coulomb and nuclear amplitudes in them-substates. The analysis of the data on elastic scattering, inelastic scattering, alignment and the neutron transfer can be described consistently with one choice of the optical model parameters.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...