Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Plant, cell & environment 4 (1981), S. 0 
    ISSN: 1365-3040
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Biology
    Notes: Abstract. The heat pulse method for determining sap flux in large woody sterns was modified for easier field operation. It uses the measurement of the time elapsed between heat pulse release by a line heater radially inserted in the stem, and the occurrence of maximum temperature 15 mm downstream of the heater. This spacing between heater and thermometer is critical to the reliability of the measurement. Calculations using uncorrected theory provide estimates of the sap flux density in stems with both uniform and non-uniform cross-sectional distribution of conducting tissues which are about 55% of the actual sap flux density. This factor results from insufficient thermal homogeneity between tissues where sap flow occurs and tissues where sap flow has been interrupted.Sap flow in trunks of citrus trees was inferred from measurements of the cross-sectional distribution of sap flux density. Variability of sap flux density is specific to each trunk and is time-dependent and imposes multiple radial and angular measurements. The method was checked in a citrus trunk ramified into three branches. Instantaneous determinations of the flow in the trunk and in the branches differed by less than 5.7%. The daily values agreed within 2.8%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Plant, cell & environment 3 (1980), S. 0 
    ISSN: 1365-3040
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Biology
    Notes: Abstract. The interception of light rays by the canopy of a widely spaced sorghum row crop was assessed from a series of hemispherical photographs taken on five occasions during its vegetative growth. Analysis of the photographs shows that most of the temporal and spatial variation in the canopy's interception could be accounted for by treating the row as an array of solid parallel walls with rectangular cross sections. Within the space occupied by rows, the effect of the distribution of foliage elements on interception could be assessed by the porosity of a single row. The north-south asymmetry observed in the distribution of ray interception indicates that this sorghum canopy, grown under unirrigated, arid summer conditions, adopted a light-avoiding growth pattern.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Irrigation science 3 (1983), S. 269-270 
    ISSN: 1432-1319
    Source: Springer Online Journal Archives 1860-2000
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Irrigation science 5 (1984), S. 73-74 
    ISSN: 1432-1319
    Source: Springer Online Journal Archives 1860-2000
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Basic research in cardiology 75 (1980), S. 600-614 
    ISSN: 1435-1803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Mit einer Methode, die in situ die Messung segmentaler koronarer Gefäßwiderstände erlaubt, wurde an narkotisierten Hunden die Reaktion arterieller und arteriolärer Abschnitte auf eine Stimulation der α-adrenergen Rezeptoren untersucht. Die linke Koronararterie wurde kanüliert und der Perfusionsdruck konstant gehalten. Extravasale und metabolische Wirkungen der α-Stimulation auf die koronaren Gefäßwiderstände wurden berücksichtigt. Eine submaximale α-Stimulation durch Xylometazolin führte zu einem Anstieg des arteriellen Widerstandes um 60% und des arteriolären Widerstandes um 90%. Die Kanülierung der linken Kranzarterie steigerte die Reaktion der arteriolären Gefäße auf eine α-Stimulation. Außerdem steigerte Xylometazolin in unseren Untersuchungen die extravasale Komponente des Koronarwiderstandes um etwa 4%. Die α-adrenerge Konstriktion könnte daher unter normalen In-vivo-Bedingungen in Arterien und Arteriolen weniger unterschiedlich sein. Da der arterielle Widerstand 20 bis 50% des koronaren Gesamtwiderstandes betragen kann, müßte eine adrenerge Vasokonstriktion dieses Gefäßabschnittes die Koronardurchblutung sogar in einem kritischen Ausmaß vermindern können. Andererseits führt aber eine überwiegende Konstriktion der arteriolären Gefäße zu einem Anstieg des peripheren koronaren Druckes und damit unter Umständen zu einem “umgekehrten Steal-Phänomen”.
    Notes: Summary Using a method which allowed the in-situ measurement of segmental coronary vascular resistances, the reaction of arterial and arteriolar sections of the coronary vascular system to α-receptor stimulation was studied in anaesthetized dogs. The left coronary artery was cannulated, and the perfusion pressure was kept constant. Allowance was made for extravascular and metabolic influences of α-stimulation on coronary vascular resistances. On an average, submaximal α-stimulation with xylometazoline increased the arterial resistance by about 60% and the arteriolar resistance by about 90%. The cannulation of the left coronary artery increased the sympathetic reactivity of the arterioles. Moreover, xylometazoline increased the extravascular component of the coronary vascular resistance by about 4%. Thus it can be assumed that under normal in-vivo conditions α-receptor vasoconstriction might be less different in coronary arteries and arterioles. Since the arterial resistance ranges from 20% to 50% of total coronary resistance, a sympathetic vasoconstriction of this vascular section might lead even to a critical limitation of coronary blood flow. On the other hand, a predominant constriction in arterioles leads to an increase in peripheral coronary pressure, i.e. to “reverse coronary steal phenomenon”.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Basic research in cardiology 75 (1980), S. 615-622 
    ISSN: 1435-1803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Das Schlagvolumen des linken Ventrikels wurde mit Hilfe einer invasiven Ultraschallmethode bestimmt. Hierzu wurde ein neues Modell entwickelt, durch welches die Form des Ventrikels gut dargestellt werden konnte. Um die Validität des Verfahrens zu prüfen, wurden umfangreiche Messungen an verschiedenen Modellkörpern, an exzidierten Hundeherzen und an schlagenden Hundeherzen durchgeführt. Für die Messungen in situ wurde ein Katheter entwickelt. An dem Teil, der in den Ventrikel vorgeschoben wurde, befanden sich drei zylinderförmige Ultraschallelemente. Mit ihnen wurde je ein Radius in einer Ventrikelebene gemessen. Zusammen mit der Messung der Länge des Ventrikels am exzidierten Herzen konnte das Ventrikelvolumen berechnet werden. Bisher wurde nur das enddiastolische und das endsystolische Volumen betrachtet. Die Auswertung der verschiedenen Messungen zeigte, daß das Verfahren gute Ergebnisse mit großer Genauigkeit und geringer Streuung liefert. Eine Ausnahme bildeten die Volumenbestimmungen an acht Hundeherzen in situ. Hier lag eine Unterschätzung des Schlagvolumens durch die Ultraschallmethode gegenüber der Farbstoffverdünnungsmethode (18,7%) und der elektromagnetischen Messung (11,7%) vor. Dieser Fehler beruht wahrscheinlich darauf, daß die Ventrikellänge bei der Volumenberechnung als konstante Größe verwendet wurde. Bei zukünftigen Messungen wird diese Größe auch mit der Ultraschallmethode bestimmt werden. Insgesamt kann gesagt werden, daß die Ergebnisse eine gute Basis dafür sind, bei zukünftigen Messungen mit demselben Katheter auch den intraventrikulären Druck fortlaufend zu messen, um auf diese Weise Untersuchungen über die Kontraktilität des linken Ventrikels in situ zu erleichtern.
    Notes: Summary The volume of the left ventricle was determined by an invasive ultrasonic method. A new model was developed which made it possible to approximate the shape of the left ventricle. In order to evaluate the method's validity, measurements were made on various geometrical solids and on canine hearts in vitro and in situ. For the measurements in situ a catheter was developed. Three cylindrical transducers were mounted in that part of the catheter, which was inserted into the left ventricle. In this way, one radius was measured in three different planes. Together with the distance apex-basis which was measured on the excised heart, these measurements were used to compute the left ventricular volume. To date, only the enddiastolic and endsystolic volumes have been analysed. The experiments which were performed on geometrical solids and on excised canine hearts showed that the method has a high accuracy and a low scatter. However, a systematic error was found while measuring the ventricular volumes of eight canine hearts in situ; the ultrasonic method underestimated the stroke volumes as compared with dye dilution (18.7%) and electromagnetic flow measurements (11.7%). This error is probably due to the fact that the ventricular length was used as a constant factor for calculating the volume. Therefore, future experiments will include the ultrasonic determination of the long axis of the ventricle. On the basis of the present results, it appears to be realistic to combine the ultrasonic catheter with a tip manometer. This will permit the continuous measurement of left ventricular volume and pressure, and thus facilitate studies on myocardial contractility in situ.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Basic research in cardiology 76 (1981), S. 494-497 
    ISSN: 1435-1803
    Keywords: segmental coronary resistances ; peripheral coronary pressure ; adrenergic receptors ; xylometazoline ; salbutamol
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Basic research in cardiology 76 (1981), S. 421-425 
    ISSN: 1435-1803
    Keywords: segmental coronary resistances ; peripheral coronary pressure ; cyanide-induced ; hypoxia ; reactive hyperemia ; coronary perfusion pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Basic research in cardiology 77 (1982), S. 520-535 
    ISSN: 1435-1803
    Keywords: coronary collateral circulation ; vascular resistance ; coronary blood flowmeter ; dogs
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Ziel der Untersuchung war es, den Einfluß des Gefäßwiderstandes der terminalen Strombahn einer ischämischen Koronararterie auf die Kollateraldurchblutung und den Kollateralwiderstand zu bestimmen. Bei 6 narkotisierten Hunden wurde der Ramus interventricularis anterior (LAD) ligiert, kanüliert und das terminale Gefäßbett mit Latexpartikeln (Durchmesser: 25 μ) verschlossen. Der retrograde Fluß wurde mittels einer neuen Methode gemessen, die es ermöglichte, den Ausflußdruck des retrograden Flusses (PRF) an der LAD-Kanüle konstant zu halten. Wurde der retrograde Fluß unterbrochen, so entsprach der Druck im verschlossenen Gefäß dem kollateralen Perfusionsdruck (CPP) im Randbezirk des ischämischen Gefäßgebietes. Der Kollateralwiderstand wurde bestimmt, indem die Druckdifferenz entlang dem kollateralen Gefäßbett (CPP-PRF) durch den retrograden Fluß dividiert wurde. Änderungen von PRF dienten als Modell für Änderungen des Widerstandes des ischämischen Gefäßbettes. Der retrograde Fluß fiel, wenn PRF angehoben wurde, von 11,0±3,0 ml×min−1×100 g−1 (PRF=0) auf 8,3±2,4 (p〈0.01) (PRF=24,6±6 mm Hg). Im selben PRF-Bereich fiel der Kollateralwiderstand von 9,68±2,96 auf 8,30±2,50 mm Hg×ml−1×min×100 g (p〈0.01). Diese Ergebnisse weisen darauf hin, daß der Widerstand der Endstrombahn des ischämischen Gefäßbettes die Kollateraldurchblutung und den Kollateralwiderstand erheblich beeinflussen kann.
    Notes: Summary The purpose of this study was to determine the influence of the resistance of the terminal vascular bed of an occluded coronary artery on collateral blood flow and collateral resistance. In 6 anesthetized dogs, left anterior descending coronary artery (LAD) was ligated, cannulated, and the terminal vascular bed was occluded by latex microspheres (diameter: 25μ). Retrograde flow was measured using a new technique, which allowed control of outflow pressure of retrograde flow (PRF) at the LAD cannula. When retrograde flow was interrupted, pressure in the occluded vessel represented collateral perfusion pressure (CPP) within the border zone of the ischemic vessel. Collateral resistance was determined dividing the pressure difference across the collateral bed (CPP-PRF) by retrograde flow. Variation of PRF was used as a model for changes in resistance of the ischemic bed. Retrograde flow fell when PRF was increased from 11.0±3.0 ml×min−1×100 g−1 (PRF=0) to 8.3±2.4 (p〈0.01) (PRF=24.6±6 mm Hg). For the same PRF range, collateral resistance fell from 9.68±2.96 to 8.30±2.50 mm Hg×ml−1×min×100 g (p〈0.01). These results indicate that the vascular resistance of the terminal ischemic bed may considerably influence collateral blood flow and resistance.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Journal of orofacial orthopedics 44 (1983), S. 48-53 
    ISSN: 1615-6714
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary An account is given of a psychosomatic procedure which tries to ascertain and resolve the patient's environmental and personal problems. Since it first deals with somatic behavioural problems and the block of respiratory rhythm and treats environmental conflicts secondarily, it is especially helpful for difficult orthodontic patients.
    Abstract: Résumé L'auteur décrit une méthode psychosomatique avec laquelle on aide le patient à trouver et à résoudre des troubles de comportement avec lui-même et son milieu. On cherche d'abord l'erreur du comportement somatique et le blocage du rythme respiratoire, puis on traite secondairement les troubles de relation avec le milieu; cette méthode est particulièrement efficace dans les soins prodigués aux patients orthodontiques qui posent quelques problèmes.
    Notes: Zusammenfassung Es wird von einer psychosomatischen Methode berichtet, die Beziehungsstörungen des Patienten mit sich selbst und der Umwelt aufspürt und zu lösen versucht. Da sie zuerst nach dem somatischen Fehlverhalten und der Atemrhythmusblockierung sucht und die Beziehungsstörung zur Umwelt sekundär bearbeitet, ist sie für kieferorthopädische Problempatienten besonders hilfreich.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...