Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 397 (1982), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 52 (1984), S. 173-177 
    ISSN: 1439-6327
    Keywords: Anaerobic threshold ; Ventilatory threshold ; Exercise ventilation ; Gas exchange ; Blood lactate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Anaerobic threshold has been defined as the oxygen uptake ( $$\dot V_{{\text{O}}_{\text{2}} }$$ ) at which blood lactate (La) begins to rise systematically during graded exercise (Davis et al. 1982). It has become common practice in the literature to estimate the anaerobic threshold by using ventilatory and/or gas exchange alterations. However, confusion exists as to the validity of this practice. The purpose of this study was to examine the precision with which ventilatory and gas exchange techniques for determining anaerobic threshold predicted the anaerobic threshold resolved by La criteria. The anaerobic threshold was chosen using three criteria: (1) systematic increase in blood La (ATLa), (2) systematic increase in ventilatory equivalent for O2 with no change in the ventilatory equivalent for CO2 ( $${\text{AT}}_{\dot V_{\text{E}} } /\dot V_{{\text{O}}_{\text{2}} }$$ ), and (3) non-linear increase in expired ventilation graphed as a function of $$\dot V_{{\text{O}}_{\text{2}} }$$ ( $${\text{AT}}_{\dot V_{\text{E}} }$$ ). Thirteen trained male subjects performed an incremental cycle ergometer test to exhaustion in which the load was increased by 30 W every 3 minutes. Ventilation, gas exchange measures, and blood samples for La analysis were obtained every 3rd min throughout the test. In five of the thirteen subjects tested the anaerobic threshold determined by ventilatory and gas exchange alterations did not occur at the same $$\dot V_{{\text{O}}_{\text{2}} }$$ as the ATLa. The highest correlation between a gas exchange anaerobic threshold and ATLa was found for $${\text{AT}}_{\dot V_{\text{E}} } /\dot V_{{\text{O}}_{\text{2}} }$$ and was r=0.63 (P〈0.05). These data provide evidence that the ATLa and $${\text{AT}}_{\dot V_{\text{E}} }$$ do not always occur simultaneously and suggest limitations in using ventilatory or gas exchange measures to estimate the ATla.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...