Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1975-1979  (4)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Bulletin of environmental contamination and toxicology 13 (1975), S. 666-672 
    ISSN: 1432-0800
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The journal of membrane biology 44 (1978), S. 103-134 
    ISSN: 1432-1424
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Summary A model is presented for “anomalous rectification” based upon electrical measurements on the egg cell membrane of the starfish. The objective is to postulate a plausible molecular mechanism which yields an expression for the conductance similar to that deduced empirically by Hagiwara and Takahashi (1974), i.e., $$G_K = \frac{{Bc_K^{1/2} }}{{1 + \exp \left( {\frac{{\Delta V - \Delta V_h }}{v}} \right)}},$$ whereB, ΔV h andv are constant,c K is the external K+ concentration, and ΔV(=V−V 0) is the displacement of the membrane potential from its resting value. It is shown that a similar dependence of the conductance on ΔV is expected for a particular class of models in which the K+ ions are also implicated in “gating”. To give a specific example, we consider the case in which the formation of ion-permeable pores requires a voltage-induced orientation of membrane-bound, electrically-charged groups and subsequent complexation of these groups with the external cations. Furthermore, the proportionality betweenG K andc 1 2/K , when the internal K+ concentration is constant, is accounted for by conventional descriptions of the ionic fluxes using Eyring's rate reaction theory. In terms of the present model,B and ΔV h are explicit functions of the internal K+ concentrations and are thus constant only as long as this is unvaried. The particular value ofv required to fit the data (v≃8.4 mV) is rationalized by the assumption that each of the orientable groups carries three negative elementary charges. In addition, the predictions of the present model are compared with those deduced from an alternative viewpoint, which is related to Armstrong's “blocking particle hypothesis”, in that the probability for opening and closing of the pore is assumed to depend on whether the pore is occupied or empty. Differences and similarities between the two models, as well as ways to discriminate between them, are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 16 (1978), S. 500-506 
    ISSN: 1741-0444
    Keywords: Biofeedback ; Limb load ; Locomotion disability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire Le dispositif électronique autonome décrit dans cet article permet de contrôler la charge exercée sur un membre par un patient lors d'exercices de marche avec appui partiel. Le dispositif mesure la charge sur le membre grâce à deux transducteurs de charge enlevables fixés à la semelle de la chaussure du malade; ils comparent cette charge avec deux valeurs-limite présélectionnées et émettent des signaux sonores de biofeedback. Une tonalité grave est émise lorsque la charge entre dans la gamme de valeur désirée, et une tonalité aigüe se déclenche lorsque la charge dépasse la valeur maximale tolérable pour le malade en question. Ce dispositif a une précision de ±10% à tous les stades de la phase de posture. Les résultats expérimentaux démontrant l'efficacité du dispositif pour le contrôle de la charge sur le membre sont également présentés.
    Abstract: Zusammenfassung Es wird ein unabhängiges Elektronikgerät zur Reglung der von einem Patienten bei einer teilgewichttragenden Gehübung angewandten Gliederbelastung beschrieben. Mit diesem Gerät wird die Gliederbelastung mit zwei abnehmbaren Belastungswandlern gemessen, die an der Schusohle des Patienten befestigt sind, die Belastung mit zwei voreingestellten Schwellwerten vergleichen und hörbare Biorückführgeräusche ausgesenden. Ein Niederfrequenzton wird dann ausgesendet, wenn die Belastung in den gewünschten Bereich fällt. Ein Hochfrequenzton wird dann erzeugt, wenn de Belastung die dem Patienten zumutbare Belastbarkeitsgrenze übersteigt. Das Gerät zeigt während aller Fußstellungsphasen eine Genauigkeit von ±10% an. Die Versuchsresultate, die die Leistung des Geräts bezüglich der Reglung der Gliederbelastung bestätigen, werden auch präsentiert.
    Notes: Abstract A selfcontained electronic device is described for controlling the limb load exerted by a patient in a partial-weight-bearing walking exercise. The device measures the limb load with two removable load transducers attached to the sole of the patient's shoe, compares the load with two preset thresholds and emits audible biofeedback tones. A low-frequency tone is emitted when the load falls in the desired range and a high-frequency tone is activated when the load exceeds the maximum load allowable for the patient. The device has an accuracy of ±10% in all stages of the stance phase. Experimental results that demonstrate the effectiveness of the device in controlling the limb load are also presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 16 (1978), S. 429-436 
    ISSN: 1741-0444
    Keywords: Footforce ; Locomotion disability ; Measuring device
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire Un appareil portatif a été conçu, construit, et essayé pour mesurer continuellement la composante verticale des forces exercées par le pied durant la marche. L'appareil consiste en deux paires de transducteurs de force, un transmetteur-amplificateur, et un récepteur. Une paire de transducteurs de force est attachée à chaque semelle de chaussures de sport, à la fois sous le métatarse et le talon. Les transducteurs sont relativement minces (6mm) et légers (65g) pour ne pas trop interférer avec l'allure habituelle de marche du patient. Les signaux détectés par les transducteurs sont amplifiés, mesurés à distance par modulation de fréquence, et rassemblés pour établir la force totale agissant sur chaque pied. Le transmetteur-amplificateur, porté par le patient, pèse environ 180 g et mesure 105×80×23 mm. La performance de l'appareil est mise à l'essai, en comparant la sortie de l'appareil avec celle d'une plaque de force courante. L'appareil a été jugé assez précis pour être destiné à l'évaluclinique de la démarche pathologique.
    Abstract: Zusammenfassung Ein tragbares Gerät zur kontinuierlichen Messung der Vertikalkomponente der während des Laufens vom Fuß aufgewandten Kräfte wurde entworfen, gebaut und getestet. Das Gerät besteht aus zwei Kraftwandlerpaaren, einem VerstärkerMeßwertgeber und einer Empfangsverarbeitungseinheit. Ein Kraftwandlerpaar wird an je einer Sohle eines Turnschuhpaars am Mittelfußknochenteil und an der Ferse angeschlossen. Die Kraftwandler sind relativ dünn (6mm) und leicht (65g), so daß sie den gewohnten Laufstil des Patienten nicht beeinflussen. Die von den Kraftwandlern aufgenommenen Signale werden verstärkt, FM-fernübertragen und summiert, um die auf jeden Fuß verwendete Gesamtkraft festzustellen. Der vom Patienten getragenen Verstärker-Meßwertgeber weegt etwa 180g und hat die Große von 105×80×23mm. Die Leistung des Gerats wird durch den Vergleich des Ausgangs des Geräts mit dem einer herkömmlichen Kraftplatte geprüft. Das Gerät wurde für den vorgesehenen, Gebrauch in der klinischen Bewertung des pathologischen Gangs als genau genug bewertet.
    Notes: Abstract A portable device has been designed, constructed and tested which measures continuously the vertical component of the forces exerted by the foot during walking. The device consists of two pairs of force transducers, an amplifier-transmitter unit, and a receiver-processing unit. A pair of force transducers are attached to the soles of a pair of sports shoes at the metatarsal region of the heel. The transducers are relatively thin (6 mm) and light (65g) so that they hardly interfere with the patient's customary walking style. The signals detected by the transducers are amplified, f.m. telemetered, and summed to give the total force acting on each foot. The amplifier-transmitter unit worn by the patient weighs about 180 g and measures 105×80×23 mm. The performance of the device is tested by comparing the output of the device with that of a conventional force plate. The device is found to be accurate enough for its intended use for the clinical assessment of pathological gait.