Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1980-1984  (6)
  • 1970-1974  (3)
Materialart
Erscheinungszeitraum
Jahr
  • 1
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 89 (1982), S. 0 
    ISSN: 1471-0528
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Summary. Serum prolactin was measured in 18 subjects complaining of premenstrual syndrome and results were compared with those in 10 control subjects. No consistent changes were seen during the course of the menstrual cycle in either group. There were no significant differences between the prolactin levels of the two groups. There was no correlation between mood change and levels of prolactin.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 89 (1982), S. 0 
    ISSN: 1471-0528
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Inorganic chemistry 21 (1982), S. 2094-2095 
    ISSN: 1520-510X
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Inorganic chemistry 22 (1983), S. 851-852 
    ISSN: 1520-510X
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    New York : Cambridge University Press
    International journal of Middle East studies 14 (1982), S. 110-112 
    ISSN: 0020-7438
    Quelle: Cambridge Journals Digital Archives
    Thema: Ethnologie , Geschichte , Politikwissenschaft
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Geophysical prospecting 22 (1974), S. 0 
    ISSN: 1365-2478
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Geologie und Paläontologie , Physik
    Notizen: A seismic trace after application of suitable amplitude recovery may be treated as a stationary time-series. Such a trace, or a portion of it, is modelled by the expression 〈displayedItem type="mathematics" xml:id="mu1" numbered="no"〉〈mediaResource alt="image" href="urn:x-wiley:00168025:GPR627:GPR_627_mu1"/〉 where j represents trace number on the record, t is time, αj is a time delay, α (t) is the seismic wavelet, s(t) is the reflection impulse response of the ground and nj is uncorrelated noise. With the common assumption that s(t) is white, random, and stationary, estimates of the energy spectrum (or auto-correlation function) of the pulse α(t) are obtained by statistical analysis of the multitrace record. The time-domain pulse itself is then reconstituted under the assumption of minimum-phase. Three techniques for obtaining the phase spectrum have been evaluated: (A) use of the Hilbert transform, (B) Use of the z-transform, (C) a fast method based on inverting the least-squares inverse of the wavelets, i.e. inverting the normal time-domain deconvolution operator. Problems associated with these three methods are most acute when the z-transform of α(t) has zeroes on or near the unit circle. Such zeroes result from oversampling or from highly resonant wavelets. The behaviour of the three methods when the energy spectra are perturbed by measurement errors is studied. It is concluded that method (A) is the best of the three. Examples of reconstituted pulses are given which illustrate the variability from trace-to-trace, from shot-to-shot, and from one shot-point medium to another. There is reasonable agreement between the minimum-phase pulses obtained by this statistical analysis of operational records and those estimated from measurements close to the source. However, this comparison incorporates a “fudge-factor” since an allowance for absorption has to be made in order to attenuate the high frequencies present in the pulse measured close to the shot.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Publishing Ltd
    Geophysical prospecting 19 (1971), S. 0 
    ISSN: 1365-2478
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Geologie und Paläontologie , Physik
    Notizen: In well velocity surveys made to calibrate Sonic (CV) Logs the calibration survey uses frequencies around 50 Hz whereas the Sonic Logging tool uses frequencies around 20 kHz. There thus exists the possibility of making a direct measure of velocity dispersion. In any one survey the disturbing factors, both instrumental and operational, will often mask any dispersive effect that might exist. Consequently this paper reports on a statistical analysis of the velocity differences resulting from calibration surveys and Sonic logs. Only Borehole Compensated Sonic Logs were used. Four areas were investigated: the North Sea, Abu Dhabi, Libya and Alaska. After rejecting logs and calibration records which were obviously in error there remained 424000 feet (about 130 km) of usable log distributed throughout 66 wells. The four areas were analysed separately and in no case was the estimated dispersion significantly different from zero. However, the mean values did correlate with lithology from (− 0.17 ± 0.18)% for the essentially carbonate section in Abu Dhabi to (+ 0.45 ± 0.25)% for the sand-shale section in Alaska, a positive sign meaning that the higher frequencies travelled faster. Except for Alaska the calibration surveys were made with a wall-clamp geophone, and for these areas amplitude measurements were made. After suitable corrections estimates of the absorption parameter Q were obtained. These varied from 20 to 200 with mean values of 63 for Libya, 70 for Abu Dhabi and 88 for the North Sea (excluding the Tertiary). If, as is usually assumed, the absorption mechanism is linear and is described by a Q which is independent of frequency, then these values would necessarily imply dispersion of several percent. As instanced above no such dispersion was observed. It is possible that the expected dispersion was compensated for by invasion of the mud filtrate into the borehole walls, but it is more likely that the absorption mechanism was substantially non-linear.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Cambridge : Cambridge University Press
    New Testament studies 21 (1974), S. 144-155 
    ISSN: 0028-6885
    Quelle: Cambridge Journals Digital Archives
    Thema: Theologie und Religionswissenschaft
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    ISSN: 1432-0428
    Schlagwort(e): Meal size ; sequence ; time of day ; carbohydrate tolerance ; insulin action ; insulin secretion
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary The effects of size, time of day and sequence of meal ingestion were determined in healthy subjects using a Latin square design. Plasma glucose, insulin and gastric inhibitory polypeptide, but not glucagon, were correlated with meal size. Plasma glucose, but not insulin, gastric inhibitory polypeptide or glucagon, were greater later in the day. The progressive decline in carbohydrate tolerance from 08.00 to 18.00 h was associated with impaired insulin secretion estimated by C-peptide, and with impaired insulin action.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...