Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 46 (1968), S. 618-619 
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Experiences with a New Test-strip for Bloodsugar Determination. Blood-sugar values were estimated in 643 in- and out-patients with the new test-strip “Haemo-Glucotest”. Blood-sugar determinations performed with the Auto-Analyzer (Hoffmann) served as an objective control. The treatment of out-patients was determined according to the values of the “Haemo-Glucotest” strip and before the Auto-Analyzer results arrived. 80% of the estimated values varied from the Auto-Analyzer results by less than ± 20 mg-%. Preliminary therapy had to be modified in only 6% of the patients. The precision of the determination depends upon illumination and the ability for color discrimination of the person working with the test-strip. The “Haemo-Glucotest” strip is not only suitable for detection of hyperglycemia and hypoglycemia, but also for control of therapy in diabetic out-patients.
    Notes: Zusammenfassung Der Teststreifen Hämo-Glucotest wurde an 643 stationär und ambulant behandelten Diabetikern erprobt. Als objektiver Vergleich dienten die Blutzuckerbestimmungen nachHoffmann im Autoanalyzer. Die Behandlung der ambulanten Patienten wurde nach den Ergebnissen des Hämo-Glucotest vor Kenntnis der Autoanalyzerbestimmung festgelegt. 80% der geschätzten Werte wichen um weniger als ± 20 mg-% von den durch Autoanalyzer bestimmten Blutzuckerwerten ab. Die nach den Testergebnissen vorläufig festgelegte Therapie der ambulanten Patienten brauchte nur in 6% der Fälle korrigiert zu werden. Die Genauigkeit der Bestimmung ist von den Beleuchtungsverhältnissen während des Tests und vom Farbunterscheidungsvermögen des Untersuchers abhängig. Der Teststreifen eignet sich nicht nur zur Erfassung von Hypo- und Hyperglykämien, sondern auch für eine orientierende Blutzuckerbestimmung bei der ambulanten Einstellungskontrolle von Diabetikern.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 46 (1968), S. 1064-1065 
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Comparison of two-test-strips for semiquantitative blood-sugar determination. Two test-strips for semiquantitative blood-sugar determination Haemo-Glucotest® and Dextrostix® were compared among themselves and to the objective blood-sugar values as determined by the method ofHoffmann et al. in 249 assays. Standard-deviation of the values estimated by the test-strips from the Autoanalyzer values was 17,13 mg-% for Haemo-Glucotest® and 35,34 mg-% for Dextrostix®. The difference was less than 30 mg-% in 92.2% of the cases for Haemo-Glucotest® and in 72.4% of the cases for Dextrostix®. The formula of the regression line wasy=0.9136x+12.4680±5.96 for Haemo-Glucotest® andy=0.4499x+78.1493 ± 20.70 for Dextrostix®. We found a correlation coefficient ofr=0.9190 for Haemo-Glucotest® and ofr=0.7212 for Dextrostix®. When 20 blood samples were assayed by 10 unexperienced testers with Haemo-Glucotest® all results, with the exception of 2 cases, varied by less than 30% from the Auto-analyzer values. Clinical suspicion of hyper- or hypoglycemia can be proven by both test-strips in every instance. Nevertheless, the Haemo-Glucotest® strip produced better results than Dextrostrix® strip in the range of about 60 to 240 mg-%.
    Notes: Zusammenfassung Die beiden Teststreifen zur semiquantitativen Blutzuckerbestimmung Hämo-Glucotest® und Destrostix® wurden in 249 Versuchen miteinander verglichen, wobei jeweils der gleiche mit der Methode nachHoffmann et al. bestimmte objektive Blutzuckerwert vorlag. Die Standardabweichung der mit den Teststreifen geschätzten Werte vom jeweils gemessenen Autoanalyzerwert lag bei Hämo-Glucotest® bei 17,13 mg-% und bei Dextrostix® bei 35,34 mg-%. Eine Abweichung von 〈30 mg-% wurde für Hämo-Glucotest® in 92,2% der Fälle und für Dextrostix® in 72,4% der Fälle festgestellt. Die Regressionsgerade hat für Hämo-Glucotest® die Formely=0,9136x+12,4680±5,96 und für Dextrostix®y=0,4499x+78,1493±20,70. Der Korrelationskoeffizient für Hämo-Glucotest® betrugr=0,9190 und für Dextrostix®r=0,7212. Bei der Untersuchung von 20 Blutproben mit Häme-Glucotest® durch 10 unerfahrene Prüfer wiesen mit Ausnahme von 2 Fällen sämtliche Ergebniss eine Abweichung von 〈30% von dem jeweiligen Autoanalyzerwert auf. Hypoglykämische Zustände können von hyperglykämischen bei entsprechendem klinischen Verdacht von beiden Teststreifen sicher unterschieden werden. Jedoch liefert der Hämo-Glucotest-Streifen im Bereich von etwa 60–240 mg-% bessere Resultate als der Dextrostix-Streifen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 70 (1966), S. 955-955 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1436-5057
    Source: Springer Online Journal Archives 1860-2000
    Topics: Computer Science
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Abstract For heatpipes with a structure of open capillaries in the transport section the vapor flow in the tube influences the laminar liquid flow in the capillaries in contrary direction by the shearing of the vapor at the free liquid surface. — The two dimensional Navier-Stokes equation for the liquid flow in the rectangular capillaries has been solved by a Fourier transformation. The evaluation yielded the friction factor of the liquid flow under the influence of the vapor shearing and has been found markedly greater than in case without vapor flow. By this effect the performance of the heatpipe is decreased (e.g. for a Na-heatpipe at 800 °C, 1 m length, 20 mm diameter, the reduction will be about 30%). At the liquid surface are zones with considerable return flow in vapor flow direction which are important for corrosion problems. — In an experimental facility have been investigated plates with different capillary geometries. In the capillaries flowed water and over the plates air in contrary direction. The decrease of the transported water flow rate with increasing air velocity has been investigated. The measured friction factors of the water flow followed rather well the predicted values. This means that the assumptions for the boundary condition at the liquid surface — locally constant shear stress and no ripple formation — hold for the solution of the Navier-Stokes equation. — If the capillaries in the plates are covered by a layer of a fine mesh no influence of the shearing of the air flow on the waterflow in the grooves has been measured. Up to airvelocities of 11.5 m/s (corresponding to an airflow Reynolds number of about 105) no entrainment of water droplets from the mesh could be observed.
    Notes: Zusammenfassung Für Wärmerohre mit offener Kapillarstruktur in der Transportzone beeinflußt die Dampfströmung im Rohrinnern die laminar in den Kapillaren rückströmende Flüssigkeitsmenge durch die Scherwirkung an ihrer freien Oberfläche. Die zweidimensionale Navier-Stokessche Gleichung für die Flüssigkeitsströmung in den Kapillaren wurde durch eine Fouriertransformation gelöst. Die Rechnung ergab, daß der Reibungsfaktor der Flüssigkeitsströmung durch die Scherwirkung des Dampfstromes gegenüber dem Fall ohne Gasreibung erheblich vergrößert wurde, wodurch die Leistung des Wärmerohres beträchtlich verringert wird (für ein Natrium-Wärmerohr bei 800 °C von 1 m Länge und 20 mm Durchmesser um 30%). An der Flüssigkeitsoberfläche treten dann starke Rückströmungen in Richtung des Gasstromes auf, die für Korrosionsbetrachtungen wichtig sind. — In einer Versuchsanlage wurden Platten mit verschiedenen Kapillargeometrien untersucht, wobei in den Kapillaren Wasser und über der Platte im Gegenstrom dazu Luft strömte. Die Abnahme der Wassermenge mit steigender Luftgeschwindigkeit wurde gemessen und die daraus ermittelten Reibungsfaktoren der Wasserströmung mit den theoretischen Werten verglichen. Es zeigte sich eine gute Übereinstimmung, wodurch die für die Lösung der Navier-Stokesschen Gleichung getroffene Annahme für die Randbedingung an der Flüssigkeitsoberfläche (örtlich konstante Schubspannung) gerechtfertigt ist. — Wenn die Kapillarrillen in den Platten mit einer Lage eines feinmaschigen Siebes abgedeckt waren, konnte ein Einfluß der Scherwirkung des Luftstromes auf den Wasserstrom in den Rillen nicht mehr festgestellt werden. Bis zur Luftgeschwindigkeiten von 11,5 m/s (entsprechend einer Reynolds-Zahl der Luftströmung von etwa 105) wurde kein Herausreißen von Wassertröpfchen aus der Siebfläche beobachtet.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 24 (1968), S. 319-330 
    ISSN: 1432-1246
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Es wird über einen Fall berichtet, der zeigt, daß in Übereinstimmung mit Mitteilungen einer Reihe anderer Autoren nach parenteralem Eindringen metallischen Quecksilbers die Möglichkeit einer resorptiven Vergiftung besteht. Auch wenn durchaus nicht immer nach entsprechenden Verletzungen eine Intoxikation resultieren muß, sondern mehrere Faktoren zur Manifestation einer Erkrankung beitragen wie Menge des Metalls, Allgemeinzustand, individuelle Disposition u. a., sind wir der Meinung, daß die Gefahr einer Quecksilberintoxikation nicht unterschätzt werden soll. Unserer Ansicht nach stellt parenteral eingedrungenes metallisches Quecksilber sowohl im Hinblick auf lokale Gewebsreaktionen wie die Möglichkeit einer resorptiven Vergiftung keinen indifferenten Stoff dar. Wir halten daher die möglichst radikale chirurgische Entfernung des Metalls, auch zur Intoxikationsprophylaxe, für indiziert.
    Notes: Summary A case is reported which shows that in conformity with information provided by other authors there is a possibility of resorptive intoxication after parenteral penetration of metallic mercury. Even if the injury does not always result in intoxication, diverse factors contribute to the symptoms of the illness e.g. the quantity of the metal, general condition, individual disposition etc., and we are of the opinion, that the dangers of intoxication by mercury should not be underrated. In our opinion parenterally penetrated metallic mercury should not be ignore as it may cause local reactions of tissue as well as to a potential resorptive poisoning. Therefore we consider it indispensable to remove the metal by surgical means as completely as possible also with regard to prophylactic treatment of intoxication.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Naturwissenschaften 53 (1966), S. 358-358 
    ISSN: 1432-1904
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Electron-interferometric measurements of the mean inner potentials are repeated with Al and Cu and for the first time performed with Ge. A new wet preparation method is used to prepare the step shaped specimens for the electron interferometer. This allows a more precise determination of the step height since the conditions under which the vacuum evaporated layers condensate are equal on the glass slide for the optical height measurement and on the specimen carrier. In the new preparation method, a glass slide is, by evaporation under vacuum, first covered with a B2O3 layer, then with a continuous base and finally with steps of the substance to be measured through a grid stencil. After dissolving the B2O3 in water, the compound foil is spread over an electron microscopic specimen carrier. The experimentally determined mean inner potential values for Ge and Cu agree well with those computed bySiota. On the other hand, the value for Al is by 2 volts higher than the computed one.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 182 (1965), S. 535-538 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 182 (1965), S. 528-530 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...