Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 81 (1997), S. 1863-1867 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: The ferromagnetic resonance (FMR) line shapes of Gd-substituted calcium vanadium garnets Y1.6−zCa1.4GdzFe4V0.4Zr0.6O12 (0.8≤z≤1.4) have been studied as the function of the Gd content. The samples had been synthesized by two different routes, with porosities varying from 0.23% to 8.9%. The FMR linewidth, ΔH, in low porosity samples is small (15–20 Oe) and becomes seven to eight times higher in high porosity samples. The linewidth can be explained on the basis of Schloemann's theory of anisotropy and porosity broadening in polycrystalline materials. The line shape is Lorentzian for low porosity and Gaussian for high porosity samples. This variation of the FMR line shape with porosity is explained on the basis of the stochastic theory. © 1997 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 1618-1621 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The "frequency squared scaling'' law, relied upon to enhance the production of high charge state ions from electron cyclotron resonance (ECR) ion sources, indicates that low frequencies of operation may not be viable for production of high ion densities, and hence for the production of high charge state ions. The superconducting electron cyclotron resonance ion source (SCECR) at the National Superconducting Cyclotron Laboratory is a fully superconducting, hexapole stabilized tandem mirror ECR ion source with a multimode microwave cavity. When operated at its optimized high magnetic field (high-B) mode at 6.4 GHz, the high charge state current output of the SCECR approaches all existing ECR ion sources, including higher frequency ECR ion sources (ECRIS). In this study, the SCECR is operated at 2.45 GHz in its high-B mode that is scaled down for that frequency of operation. Initial results with oxygen and argon ion production at 2.45 GHz are presented. It is demonstrated that the SCECR can produce a plasma from which multiply charged ions of up to O7+ and Ar13+ can be extracted with ion current intensities comparable to several higher frequency ECRIS. This study concludes that 2.45 GHz is indeed a viable frequency for production of moderate intensities of multiply charged ions. This may lead to a simpler, and more cost effective microwave apparatus, with a less demanding magnetic field configuration. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 4109-4113 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A series of systematic tests have been carried out on the superconducting electron cyclotron resonance ion source SCECRIS at the Michigan State University National Superconducting Cyclotron Laboratory in order to better understand the role of different parameters which determine the performance of these sources. A relevant part of these tests has been focused on the role of magnetic field and microwave frequency, with the goal of demonstrating the capability of low frequency electron cyclotron resonance ion sources to produce high ion charge states, in spite of their relative low plasma density. This goal can be achieved using a very high magnetic confining field, according to the concept of a high B mode. A comparison of the source performance at 2.45 and 6.4 GHz for different levels of magnetic field is described in this article. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 67 (1996), S. 927-927 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The "frequency squared scaling'' law, relied upon to enhance the production of high charge state ions from electron cyclotron resonance (ECR) ion sources, indicates that low frequencies of operation may not be viable for production of high ion densities, and hence for the production of high charge state ions. The superconducting electron cyclotron resonance ion source (SCECR) at the National Superconducting Cyclotron Laboratory is a fully superconducting, hexapole stabilized tandem mirror ECR ion source with a multimode microwave cavity. When operated at its optimized high magnetic field (high-B) mode at 6.4 GHz, the high charge state current output of the SCECR approaches all existing ECR ion sources, including higher frequency ECR ion sources (ECRIS). In this study, the SCECR is operated at 2.45 GHz in its high-B mode that is scaled down for that frequency of operation. Initial results with oxygen and argon ion production at 2.45 GHz are presented. It is demonstrated that the SCECR can produce a plasma from which multiply charged ions of up to O7+ and Ar13+ can be extracted with ion current intensities comparable to several higher frequency ECRIS. This study concludes that 2.45 GHz is indeed a viable frequency for production of moderate intensities of multiply charged ions. This may lead to a simpler, and more cost effective microwave apparatus, with a less demanding magnetic field configuration. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 1028-1034 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: The magnitude and spatial variation of the impressed electric-field patterns inside a compact electron cyclotron resonance ion/plasma source are experimentally measured for argon and nitrogen feed gases. This ECR plasma source consists of several components: a resonant coaxial coupling section, an evanescent circular waveguide section, coupling loop, and the ECR discharge load itself. The electric fields inside the coaxial and circular waveguide sections are measured as the operating pressure and input power and are varied from 0.2 to 2.0 mTorr and 100 to 170 W, respectively. The measured fields verify that a standing wave with a maximum of 20–40 kV/m exists inside the coaxial section of length l. For matched conditions the length of this section varies only slightly between 0.6 and 0.7λ as pressure, power, and gas type vary. However, the evanescent impedance-matching circular waveguide section of length d changes from 2.5 for argon to 3.2 cm for nitrogen, indicating that the gas type influences the plasma impedance. Field pattern measurements in the ECR section of the source demonstrate the presence of nonevanescent fields in the discharge region. Measured plasma loaded and unloaded quality factors varied from 220 to 1800, respectively, indicating that 87% of the net input power is coupled into the discharge load. Additional calculations of conductive wall losses show that about 6% of the input power is lost in the cavity walls, and the remaining 7% is lost in the coupling loop. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 69 (1996), S. 1786-1788 
    ISSN: 1077-3118
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: Monte Carlo calculations of the electron drift velocity in polycrystalline diamond are presented based on a formulation that includes grain boundary scattering. Our results indicate field dependent reductions of the drift velocity in polycrystalline diamond. The grain boundaries are predicted to have negligible effect on the drift velocity at high fields exceeding 70 kV/cm. However, significant drift velocity decreases are predicted at fields below 1 kV/cm, and at low temperatures. This trend is in keeping with experimental mobility data that is becoming available from pulsed excitation measurements. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 72 (1998), S. 1685-1687 
    ISSN: 1077-3118
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: In the present investigation, we have studied the effect of electric field on the growth of carbon nanotubules. Different electric fields corresponding to 3, 6, 9, 15, and 21 V have been applied during the growth of the tubules. The estimate of the electric field corresponding to these voltages cannot be precisely evaluated in view of only approximately defined electrode dimensions. It has been observed that the application of electric field leads to the agglomerates (bundles) of nanotubules. The size, length, and alignment of these bundles varies with the strength of the applied electric field. The best results have been obtained with electric field corresponding to 6 V where the as-formed tubules are in parallel alignment and exist as bundles. As the electric field is increased, the alignment of tubules in the bundle becomes randomly oriented. The degree of randomness increases with increase of electric field after its optimum value corresponding to 6 V. The parallel alignment of the graphitic tubules is thought to result due to orientation of the tubule axis along the direction of the applied electric field corresponding to an optimum value (which for the present case is 6 V) of the impressed voltage. © 1998 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    Macromolecules 28 (1995), S. 827-832 
    ISSN: 1520-5835
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie , Physik
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Science Ltd
    Haemophilia 9 (2003), S. 0 
    ISSN: 1365-2516
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Summary.  Successful models for factor replacement in severe haemophilia involves prophylactic or on-demand administration of large quantities (1500–9000 IU kg−1 year−1) of very high purity factor concentrates starting early in life. The prohibitive cost of these protocols make them completely impractical in developing countries where the quantity of factor used for replacement therapy is much lower and varies considerably (25–500 IU kg−1 year−1). At this level of treatment, as some joint damage is inevitable, the aim of therapy shifts to preventing disability and preserving reasonable joint function rather than perfect architecture. There are no carefully recorded data on long-term outcome of musculo-skeletal function on these doses. Appropriate studies are needed to document such data. With regard to products for factor replacement, economic compulsions lead to the use a variety of factor concentrates and blood-bank products for replacement therapy. Most patients in the developing world do not have access to adequate replacement therapy. Among the rest, some get limited quantities of plasma-derived concentrates while others use cryoprecipitate, fresh frozen plasma or even whole blood. Since the superiority of virus-inactivated purified factor concentrates in achieving the aims of replacement therapy is well established, the aim should be to provide this for all people with haemophilia. This can be achieved by production of such concentrates locally or by importing them. Different models are possible depending on the circumstances in each country.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Science Ltd
    Haemophilia 10 (2004), S. 0 
    ISSN: 1365-2516
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Summary.  The objective of this study was to assess the frequency of factor VIII (FVIII) gene intron 1 and intron 22 inversions and the informativeness of polymorphic markers for the genetic diagnosis of patients with haemophilia A (HA). Fifty unrelated patients with HA were first assessed for the intron 1 and intron 22 inversion mutations. Inversion-negative families were then screened for the bi-allelic intragenic markers – intron 7 G→A polymorphism, HindIII site in intron 19 and XbaI site in intron 22 and the multiallelic dinucleotide CA repeat alleles in introns 13 and 22. The extragenic, multiallelic VNTR DXS52 (st14) was also analysed. Intron 22 inversion mutation was found in 38% (n = 19) of all patients and 46% of those with severe HA. Intron 1 inversion was found in one (2%) patient. Of the 30 inversion-negative families, XbaI site polymorphism was the single most informative marker (70%, n = 21/30) followed by HindIII (60%, n = 18/30), intron 13 CA repeats (56.66%, n = 17/30), intron 22 CA repeats (50%, n = 15/30), DXS52 VNTR (23.33%, n = 7/30) and intron 7 G→A polymorphism (6.66%, n = 2/30). The combined use of these markers was informative in 92% (n = 46/50) of HA families. Based on the informativeness of these markers a comprehensive algorithm has been proposed for genetic diagnosis of HA in India.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...