Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1955-1959  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 44 (1956), S. 319-333 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary If lead in biological material is accumulated in the ash, it may be determined by means of even an intermediate spectrograph. The greater part of accompanying substances is extracted from the ash with a reagent which leaves the lead and other heavy metals behind undissolved. The enriched ash together with a bonding solution is dried on aluminium electrodes. A duplicate determination can be carried out with 2 ml blood if the lead content is of the order of 20μg per 100 ml.
    Abstract: Résumé En chimie biologique on peut doser le plomb à l'aide d'un spectrographe «médium» après enrichissement des cendres. La majeure partie des autres éléments est éliminée par un réactif qui laisse le plomb et les autres métaux lourds. Les cendres enrichies sont séchées sur électrodes d'aluminium en même temps qu'une solution complexante. 2 ml de sang suffisent pour un double dosage à une concentration de 20μg dans 100 ml.
    Notes: Zusammenfassung Blei läßt sich in biologischem Material auch mit einem mittleren Spektrographen bestimmen, wenn es in der Asche angereichert wird. Der größte Teil der Begleitstoffe wird aus der Asche mit einem Reagens extrahiert, das Blei und andere Schwermetalle ungelöst zurückläßt. Die angereicherte Asche wird zusammen mit einer Haftlösung auf Aluminiumelektroden eingetrocknet. 2 ml Blut genügen für eine Doppelbestimmung bei einem Bleigehalt von 20μg in 100 ml.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 43 (1955), S. 358-375 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An improvement is made in the spectrochemical detection of nonmetals with powerful low tension sparks. It was found possible to raise the detection sensitivity particularly by also lowering the self-induction. Details of the apparatus were more suitably constructed. Sulfur and halogens (except fluorine) can be detected down to quantities below 1μg; the fluorine lines become visible at 10 μg. It is easy to show the presence of argon in the air. The sulfur is readily detected in noble metals damaged by sulfur, and this element is distinctly revealed in steels down to 0.02% or less. Fundamentally, the determination of hydrogen in metals has been proved possible by earlier experiments. The conditions are stated and a discussion of the opposing demands of excitation and volatilization is included. Several theoretical remarks about low tension sparks conclude the paper.
    Abstract: Résumé On a perfectionné la détection des éléments non métalliques à l'aide d'une étincelle de puissance à basse tension. Il est possible d'augmenter la sensibilité de détection, particulièrement en diminuant la self-induction. On donne des détails de construction des appareils les plus convenables. On peut détecter le soufre et les halogènes (sauf le fluor) jusqu'à 1μg; les raies du fluor sont visibles à partir de 10 μg. On montre facilement la présence d'argon dans l'air. On détecte aisément le soufre dans les métaux nobles altérés par du soufre; dans les aciers, on révèle distinctement cet élément jusqu'à 0,02% et même moins. La détection de l'hydrogène dans les métaux est possible. On décrit les conditions et discute les exigences opposées de la volatilisation et de l'excitation. On termine par diverses remarques théoriques sur les étincelles à basse tension.
    Notes: Zusammenfassung Der spektrochemische Nachweis der Nichtmetalle mit dem stromstarken Niederspannungsfunken wurde verbessert. Es gelang, die Nachweisempfindlichkeit besonders auch durch Herabsetzung der Selbstinduktion zu steigern. Apparative Einzelheiten wurden zweckmäßiger gestaltet. Schwefel und Halogene außer Fluor können bis zu Mengen unter 1 μg herab nachgewiesen werden, die Fluorlinien werden bei 10 μg sichtbar. Der Argongehalt der Luft ist leicht nachzuweisen. In schwefelgeschädigten Edelmetallen zeigt sich der Schwefel sehr deutlich, ebenso in Stahlproben bis zu einem Gehalt von 0,02% und darunter. Die Bestimmung des Wasserstoffs in Metallen ist nach früheren Versuchen grundsätzlich möglich. Die Bedingungen werden angegeben und die gegensätzlichen Anforderungen der Anregung und der Verdampfung besprochen. Den Schluß bilden einige theoretische Bemerkungen über den Niederspannungsfunken.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...