ISSN:
1432-0649
Keywords:
42.55G
;
42.60B
;
52.80H
Source:
Springer Online Journal Archives 1860-2000
Topics:
Physics
Notes:
Abstract An X-ray preionized, discharge-pumped XeCl laser with a variable beam cross-section of up to 6×6 cm2 is described. It uses flat electrodes and the beam width is determined by X-ray collimation. Its operation characteristics concerning reduced electric field strength (E/p) and X-ray dose are discussed in detail. The inductance of the discharge loop is minimized using a water capacitor arrangement. A very high specific optical power (90 MW/l) is achieved in an active volume of 1.2 l. The pulse energy exceeds 5 J in a 45 ns pulse (FWHM).
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF00324182