Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 65D07  (2)
  • Susceptibility  (2)
  • Ultrasonic  (2)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    BIT 27 (1987), S. 374-388 
    ISSN: 1572-9125
    Schlagwort(e): 65D07 ; 65L05
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Mathematik
    Notizen: Abstract In this paper the general classV of spline-collocation methods for first order systems of ordinary differential equations is investigated. The methods can in part be regarded as so-called multivalue methods. This type contains the generalized singly-implicit methods treated by Butcher. It is shown here, how any multivalue type representative ofV yields a matrix valued functionψ, for the characterization of stability at infinity. It is shown in particular, that the structure ofψ allows us to construct infinity-stable methods by an appropriate choice of the collocation points.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    BIT 29 (1989), S. 295-310 
    ISSN: 1572-9125
    Schlagwort(e): 65L05 ; 65L20 ; 65D07 ; Ordinary differential equations ; collocation methods ; A-stability ; confluence
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Mathematik
    Notizen: Abstract In this paper the general classV of spline-collocation methods presented by Mülthei is investigated. The methods ofV approximate solutions of first order initial value problems. ClassV contains as subclass the methods of so-called multivalue type, and in particular contains the generalized singly-implicit methods treated by Butcher. Any multivalue type representativeU εV yields a matrix valued function Ω corresponding toU, which characterizes the region of absolute stability ofU. If a sequence (U(δ)) of multivalue type representatives ofV tending to some singlevalue type representative $$\tilde U$$ εV is considered, it can easily be seen by the structure of Ω, that the sequence of the greatest eigenvalues of the Ω(.,δ) tends to the stability function $$\tilde R$$ corresponding to $$\tilde U$$ . This fact allows one to construct one-parameter families of A-stable methods of multivalue type.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Journal of nondestructive evaluation 17 (1998), S. 141-152 
    ISSN: 1573-4862
    Schlagwort(e): Ultrasonic ; EMAT ; applied stress ; strain ; Rayleigh wave ; bridge
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Elektrotechnik, Elektronik, Nachrichtentechnik , Mathematik
    Notizen: Abstract The measurement of applied stress on bridges can provide valuable information on the condition of the structure. The conventional technique for measuring applied stress is with a strain gage. However, strain gages can be time consuming to install because first the surface must usually be prepared. On a bridge, paint removal will most likely be necessary as part of this surface preparation. When dealing with lead-based paints, which are considered hazardous waste, many time consuming removal procedures are required. Because of these factors, a device that measures applied stress without requiring paint removal could be useful. While a “clamp-on” strain gage can also be used to measure applied stress without requiring paint removal, this type of strain gage can not be used on some bridge details, such as webs of I-beams and tops of box girders. An ultrasonic technique using non-contact electromagnetic transducers provides a possible method for applied stress measurement which is not limited by the same factors as those with conventional strain gages. The transducers operate through nonconductive and conductive (lead-based) paint and work on rusted, pitted surfaces. Our previous research developed a technique for measuring applied stresses on bridges with EMATs and included many laboratory tests. This paper describes field applications of the technique on actual bridge structures, as well as additional system testing and instrument calibration in the laboratory.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Journal of nondestructive evaluation 17 (1998), S. 141-152 
    ISSN: 1573-4862
    Schlagwort(e): Ultrasonic ; EMAT ; applied stress ; strain ; Rayleigh wave ; bridge
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Elektrotechnik, Elektronik, Nachrichtentechnik , Mathematik
    Notizen: Abstract The measurement of applied stress on bridges can provide valuable information on the condition of the structure. The conventional technique for measuring applied stress is with a strain gage. However, strain gages can be time consuming to install because first the surface must usually be prepared. On a bridge, paint removal will most likely be necessary as part of this surface preparation. When dealing with lead-based paints, which are considered hazardous waste, many time consuming removal procedures are required. Because of these factors, a device that measures applied stress without requiring paint removal could be useful. While a “clamp-on” strain gage can also be used to measure applied stress without requiring paint removal, this type of strain gage can not be used on some bridge details, such as webs of I-beams and tops of box girders. An ultrasonic technique using non-contact electromagnetic transducers provides a possible method for applied stress measurement which is not limited by the same factors as those with conventional strain gages. The transducers operate through nonconductive and conductive (lead-based) paint and work on rusted, pitted surfaces. Our previous research developed a technique for measuring applied stresses on bridges with EMATs and included many laboratory tests. This paper describes field applications of the technique on actual bridge structures, as well as additional system testing and instrument calibration in the laboratory.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Springer
    European journal of clinical microbiology & infectious diseases 17 (1998), S. 197-201 
    ISSN: 1435-4373
    Schlagwort(e): Key words Quinupristin/dalfopristin ; Streptococcus pneumoniae ; Haemophilus influenzae ; Quality control ; Susceptibility
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract  Studies were undertaken to select tentative criteria for susceptibility testing of quinupristin/dalfopristin against Streptococcus pneumoniae and Haemophilus influenzae. Against 612 isolates of Streptococcus pneumoniae, MICs of quinupristin/dalfopristin were ≤1.0 μg/ml for all but one strain. With a tentative MIC breakpoint of either ≤1.0 μg/ml or ≤2.0 μg/ml for susceptible, a disk diffusion zone diameter breakpoint of ≥19 mm embraced all but two of the susceptible pneumococci;≥16 mm included all strains. For Haemophilus influenzae, MICs of quinupristin/dalfopristin clustered near the tentative breakpoints; 91.5% of the MICs were 2.0 to 8.0 μg/ml. This precluded satisfactory performance of the disk diffusion test in discriminating between resistant and susceptible isolates unless MIC breakpoints are modified for this species: clinical experience will be needed before that can be justified. Based on data from a multilaboratory study, the following quality control limits are proposed for Streptococcus pneumoniae ATCC 49619 when testing quinupristin/dalfopristin: 0.25 to 1.0 μg/ml for broth microdilution tests and 19 to 24 mm for disk diffusion tests. For tests of Haemophilus influenzae ATCC 29247, MIC limits are 2.0 to 16 μg/ml; disk tests were very reproducible but are not yet recommended.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    European journal of clinical microbiology & infectious diseases 17 (1998), S. 197-201 
    ISSN: 1435-4373
    Schlagwort(e): Quinupristin/dalfopristin ; Streptococcus pneumoniae ; Haemophilus influenzae ; Quality control ; Susceptibility
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Studies were undertaken to select tentative criteria for susceptibility testing of quinupristin/dalfopristin againstStreptococcus pneumoniae andHaemophilus influenzae. Against 612 isolates ofStreptococcus pneumoniae, MICs of quinupristin/dalfopristin were ≤1.0 μg/ml for all but one strain. With a tentative MIC breakpoint of either ≤ 1.0 μg/ml or ≤2.0 μg/ml for susceptible, a disk diffusion zone diameter breakpoint of ≥19 mm embraced all but two of the susceptible pneumococci; ≥16 mm included all strains. ForHaemophilus influenzae, MICs of quinupristin/dalfopristin clustered near the tentative breakpoints; 91.5% of the MICs were 2.0 to 8.0 μg/ml. This precluded satisfactory performance of the disk diffusion test in discriminating between resistant and susceptible isolates unless MIC breakpoints are modified for this species: clinical experience will be needed before that can be justified. Based on data from a multilaboratory study, the following quality control limits are proposed forStreptococcus pneumoniae ATCC 49619 when testing quinupristin/dalfopristin: 0.25 to 1.0 μg/ml for broth microdilution tests and 19 to 24 mm for disk diffusion tests. For tests ofHaemophilus influenzae ATCC 29247, MIC limits are 2.0 to 16 μg/ml; disk tests were very reproducible but are not yet recommended.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...