Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 5-HT2A receptor  (1)
  • 99mTc-DTPA clearance  (1)
  • 1
    ISSN: 1432-2072
    Keywords: Key words Alcohol ; Ethanol ; Saccharin ; Self-administration ; Serotonin ; 5-HT1A receptor ; 5-HT2A receptor ; Rat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Both 5-HT1A and 5-HT2A receptors have been implicated in modulating ethanol self-administration. A novel serotonergic compound, FG 5974, with combined 5-HT1A agonist/5-HT2A antagonist activities, has shown effects in decreasing ethanol consumption in two-bottle choice paradigms. In the present study, the effect of this compound on operant responding for ethanol (as well as water and a saccharin solution) was compared to compounds possessing the separate neuropharmacological effects of this drug (the 5-HT1A agonist, 8- OH-DPAT, and the 5-HT2A antagonist, amperozide). While all three serotonergic compounds decreased operant responding for ethanol, only FG 5974 had no effect on water and saccharin responding. These results suggest that combined 5HT1A agonist/5-HT2A antagonist activity provides a more selective effect on ethanol reinforcement than either neuropharmacological action alone. Therefore, further analysis of mixed serotonergic compounds in general, and FG 5974 in particular, is warranted as they offer potential treatments for alcoholism.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 11 (1985), S. 7-12 
    ISSN: 1619-7089
    Keywords: Glomerular filtration rate ; 99mTc-DTPA clearance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The relative accuracy of five simplified methods of measuring glomerular filtration rate was prospectively assessed using 99mTc-DTPA. The slope of the biological clearance curve, the 3-h volume of dilution and three renal tracer uptake methods (Piepsz, Gates and Nielsen) were concurrently compared with a multiple blood sampling reference method. The volume of dilution method from a single blood sample was markedly superior to the other four simplified methods which all had a similar degree of accuracy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗