Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1920
    Keywords: Internal auditory canal ; Acoustic schwannoma ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Prospective baseline MRI was obtained on 31 patients who had “total” removal of acoustic schwannoma 6 months to 9 years previously. Follow-up MRI was performed after 1–2 years on patients with questionable abnormalities. We found four patterns (1) internal auditory canals (IAC) with nonenhancing soft-tissue strands, possibly scars or distorted residual nerves (8); (2) IAC with marginal enhancement-reactive dura mater (16); (3) IAC with contrast-enhancing globular tissues suggesting residual or recurrent tumour (5); (4) high-signal intensity in the IAC before contrast medium administration, probably related to graft with fat/fascia/muscle (2). Prospective 1-to 2-year follow-up studies were available in 8, 5, and 1 patients in groups 2, 3, and 4 respectively. In group 2, dural enhancement remained unchanged in 5 patients and decreased in 3. In group 3 follow-up showed 1 tumor recurrence (surgically confirmed) and 4 stable abnormalities. In group 4, follow-up in 1 of the 2 patients was stable. In groups 1 and 2, the MRI features correlate well with complete tumor removal. Whether follow-up in these groups is indicated needs to be determined. In group 3 residual or recurrent tumor cannot be excluded. In group 4, grafts may prevent adequate visualization of the IAC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1920
    Keywords: Key words Internal auditory canal ; Acoustic schwannoma ; Magnetic resonance imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Prospective baseline MRI was obtained on 31 patients who had “total” removal of acoustic schwannoma 6 months to 9 years previously. Follow-up MRI was performed after 1–2 years on patients with questionable abnormalities. We found four patterns (1) internal auditory canals (IAC) with nonenhancing soft-tissue strands, possibly scars or distorted residual nerves (8); (2) IAC with marginal enhancement-reactive dura mater (16); (3) IAC with contrast-enhancing globular tissues suggesting residual or recurrent tumour (5); (4) high-signal intensity in the IAC before contrast medium administration, probably related to graft with fat/fascia/muscle (2). Prospective 1- to 2-year follow-up studies were available in 8, 5, and 1 patients in groups 2, 3, and 4 respectively. In group 2, dural enhancement remained unchanged in 5 patients and decreased in 3. In group 3 follow-up showed 1 tumor recurrence (surgically confirmed) and 4 stable abnormalities. In group 4, follow-up in 1 of the 2 patients was stable. In groups 1 and 2, the MRI features correlate well with complete tumor removal. Whether follow-up in these groups is indicated needs to be determined. In group 3 residual or recurrent tumor cannot be excluded. In group 4, grafts may prevent adequate visualization of the IAC.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...