Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 1432-1238
    Schlagwort(e): Key words Aged ; Functional residual capacity ; Lung volume measurement ; Mechanical ventilation ; Critical care ; Chronic obstructive pulmonary disease ; Acute lung injury
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: Validation of an open-circuit multibreath nitrogen washout technique (MBNW) for measurement of functional residual capacity (FRC). The accuracy of FRC measurement with and without continuous viscosity correction of mass spectrometer delay time (TD) relative to gas flow signal and the influence of baseline FIO2 was investigated. Design: Laboratory study and measurements in mechanically ventilated patients. Setting: Experimental laboratory and anesthesiological intensive care unit of a university hospital. Patients: 16 postoperative patients with normal pulmonary function (NORM), 8 patients with acute lung injury (ALI) and 6 patients with chronic obstructive pulmonary disease (COPD) were included. Interventions: Change of FIO2 from baseline to 1.0. Measurements and main results: FRC was determined by MBNW using continuous viscosity correction of TD (TDdyn), a constant TD based on the viscosity of a calibration gas mixture (TD0) and a constant TD referring to the mean viscosity between onset and end of MBNW (TDmean). Using TDdyn, the mean deviation between 15 measurements of three different lung model FRCs (FRCmeasured) and absolute volumes (FRCmodel) was 0.2 %. For baseline FIO2 ranging from 0.21 to 0.8, the mean deviation between FRCmeasured and FRCmodel was −0.8 %. However, depending on baseline FIO2, the calculation of FRC using TDmean and TD0 increased the mean deviation between FRCmeasured and FRCmodel to 2–4 % and 8–12 %, respectively. In patients (n = 30) the average repeatability coefficient was 6.0 %. FRC determinations with TDmean and TD0 were 0.8–13.3 % and 4.2–23.9 % (median 2.7 % and 8.7 %) smaller than those calculated with TDdyn. Conclusion: A dynamic viscosity correction of TD improves the accuracy of FRC determinations by MBNW considerably, when gas concentrations are measured in a sidestream. If dynamic TD correction cannot be performed, the use of constant TDmean might be suitable. However, in patient measurements this can cause an FRC underestimation of up to 13 %.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 69 (1997), S. 1313-1313 
    ISSN: 0009-286X
    Schlagwort(e): Chemistry ; Industrial Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...