Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1238
    Keywords: Mechanical ventilation ; Endotracheal tubes ; Obstruction ; Acute respiratory failure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective To evaluate the efficiency of a new device developed to remove obstructions from endotracheal tubes (ETT) in mechanically ventilated patients. Design Open study in mechanically ventilated sedated and paralyzed ICU patients. Setting General ICU and Laboratory of Respiratory Mechanics of the University of Rome “La Sapienza”. Patients 8 consecutive unselected mechanically ventilated, critically ill patients in which a partial obstruction of ETT was suspected on the basis of an increase of the peak inspiratory pressure (〉20%) plus the difficult introduction of a standard suction catheter. Interventions Obstructions to ETT were removed with an experimental “obstruction remover” (OR) Measurements “In vivo” ETT airflow resistance (0.25; 0.5; 0.75; 1l/s) was evaluated before and after use of the OR; the work of breathing necessary to overcome ETT resistance (WOBett) was also evaluated before and after OR use. Results The use of OR significantly reduced in all patients the ETT “in vivo” resistance (From 5.5±2.3 to 2.9±0.5 cmH2O/l/s at 0.25l/s,p〈0.05; from 9±2.4 to 3.8±0.8 cmH2O/l/s at 0.51l/s; from 12.2±3.5 to 5.7±1.2 cmH2O/l/s at 0.75l/s; from 16.9±6 to 9.3±3.8 cmH2O/l/s at 1l/s,p〈0.01 respectively). Also the WOBett was significantly reduced after use of the OR (from 0.66±0.19 to 0.34±0.08 J/l;p〈0.05) Conclusion This experimental device can be safely and successfully used to remove obstructions from the ETT lumen, without suspending mechanical ventilation, reducing the need for rapid ETT substitution in emergency and life-threatening situations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Auto-PEEP ; COPD ; Pressure support ventilation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report a case of hyperinflation induced isorythmic atrio-ventricular dissociation with circulatory failure in a patient with chronic obstructive pulmonary disease. The arrythmia was successfully treated by applying “pressure support ventilation” (PSV: 20 cmH2O) which, by decreasing the respiratory rate and increasing the expiratory time reduced the level of auto-PEEP. In order to explain this result the Authors recorded, in the same patient, the level of auto-PEEP and ΔFRC obtained with Intermittent Positive Pressure Ventilation (IPPV), Intermittent Mandatory Ventilation (IMV) and PSV at the same gas exchange values. PSV showed a dramatic reduction of both these parameters. (Auto-PEEP: IPPV 12 cmH2O, IMV 17 cmH2O, PSV 7 cmH2O).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: COPD ; High frequency jet ventilation ; Auto-PEEP
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We investigated the levels of auto-PEEP and dynamic hyperinflation during high frequency jet ventilation (HFJV) and controlled mechanical ventilation (CMV) in six patients with chronic obstructive pulmonary disease within the first 36 h of acute exacerbation. The comparative evaluation was performed at similar conditions of gas exchange in HFJV and CMV: PaO2 77.6±11 mmHg vs 80.8±12 mmHg; PaCO2 46.8±2.5 mmHg vs 47±2.8 mmHg; pH 7.38 vs 7.38. In this situation, the values of auto-PEEP and dynamic hyperinflation, expressed as Δ over the apneic functional residual capacity (FRC) did not differ: (auto-PEEPHFJV 8.9±3.8 cmH2O; auto-PEEPCMV 8.8±4.7 cmH2O; ΔFRCHFJV 0.56±0.19 l; ΔFRCCMV 0.54±0.2 l). This result suggests that, with a suitable machine setting and similar gas exchanges, HFJV produces the same level of auto-PEEP and dynamic hyperinflation as CMV in patients with chronic obstructive pulmonary disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...