Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 5 (1984), S. 1039-1052 
    ISSN: 1572-9559
    Keywords: H2O laser ; Faraday rotation ; polarimetry ; far-infrared ; plasma diagnostics ; compact toroid
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A fast response frequency-modulated interferometric polarimeter was designed and constructed with a single 28 μm H2O laser for high density plasma diagnostics. This newly developed modulation system employs an electro-magnetically driven movable mirror to achieve the modulation frequency beyound 1 MHz for about 100 μs duration. The movable mirror performance is studied experimentally in detail. The determination of the Faraday rotation angle is based on the zero-crossing method for the observed beat signals produced by two kinds of rotating plane-polarized waves. The feasibility of the polarimeter constructed was verified in experiments of a field-reversed thetapinch plasma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 2 (1981), S. 1199-1208 
    ISSN: 1572-9559
    Keywords: water vapor laser ; plasma diagnostics ; interferometer ; waveguide laser ; far-infrared
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A high-power CW 27.972 μm water vapor laser has been constructed in order to use as a light source of an interferometer for plasma diagnostics. The laser consists of 220 cm length and 2.0 cm small bore Pyrex glass discharge tube, semi-confocal resonator and Michelson coupler. From the measurement of cavity detuning curves, it is found that two waveguide modes, EH11 and EH21 oscillate. The increase of the output power is found to become more than seven times larger by adding He(50%)−H2(50%) mixed gas. Under the optimum condition, the maximum output power of 65 mW or the output power per unit cavity volume of 83 μW/cm3 is obtained.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 4 (1983), S. 549-559 
    ISSN: 1572-9559
    Keywords: interferometer ; polarimeter ; water-vapor laser ; far-infrared ; plasma diagnostics ; compact toroid
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A high-power CW 27.972 μm water-vapor laser has been developed for interferometric and polarimetric measurements of plasmas. The maximum output power and the power density in the cavity of the laser with 2.0 cm bore and 220 cm length reach 85 mW and 109 μW/cm3, respectively. An interferometer using this laser is constructed and its performance is examined as a study on polarimetric method of magnetic field measurement. Preliminary interferometric experiments are also carried out on a compact toroidal plasma with field-reversal configuration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 23 (1985), S. 43-47 
    ISSN: 1741-0444
    Keywords: Admittance plethysmography ; Arterial compliance ; Arterial volume ; Vascular unloading technique ; Volume elastic modulus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Static and dynamic (beat-to-beat) arterial viscoelastic properties were measured noninvasively in human fingers and forearms. The volume change and pressure change were detected simultaneously by admittance plethysmography and by sphygmomanometry using the vascular unloading technique in the index and middle finger, or vice versa. These simultaneous measurements were also made on the forearms of one side and the fingers of the other side. The arterial viscoelastic properties in these segments could be successfully determined at different transmural pressure levels from 0 mm Hg to around the mean arterial pressure.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 26 (1988), S. 641-646 
    ISSN: 1741-0444
    Keywords: Admittance plethysmography ; Arterial compliance ; Human limb ; Noninvasive measurement ; Volume elastic modulus ; Volume oscillometric method
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract Arterial elasticity expressed by such indices as volume elastic modulus Ev and compliance Ca were noninvasively measured in various human limb segments; the upper arms, forearms, fingers, thighs, calves and toes. These indices are defined, respectively, as $$E_v = \Delta P/(\Delta V/\bar V_a )$$ and Ca=ΔV/ΔP, where ΔP is pulse pressure, $$\bar V_a $$ mean arterial volume and ΔV its pulsatile variation. ΔP was calculated from systolic Pas and mean Pam arterial pressures determined by volume oscillometric sphygmomanometry using the following equation: $$\Delta P = 3(P_{as} - P_{am} )/2\bar V_a $$ and the ΔV were detected by electrical admittance plethysmography at various transmural pressure Pt levels controlled by a compression cuff. The values obtained in these limb segments were compared with each other at Pt levels 0,30 and 60 mm Hg and the differences between them were discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1741-0444
    Keywords: Admittance plethysmography ; Respiration rate ; Stroke volume ; Three-channel telemetry ; Total transthoracic admittance
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A three-channel frequency-modulation telemetry system for the noninvasive measurement of cardiac output, rate of respiration, e.c.g. and basal transthoracic admittance of the unconstrained human subject is described. Tetrapolar admittance plethysmography has been employed to obtain the transthoracic admittance and its variations corresponding to the cardiac cycle and respiratory changes. Pulse duration modulation has been used in the transmitter system. The nonlinearity of the system is less than ±2·0%. The telemetry transmitter has a range of about 100 m, it weights approximately 200 g and is contained in a box measuring 150×100×50 mm. The batteries used provide a continuous life of 20 h. The system has been used to obtain data from normal subjects in different postures with breath hold and during normal respiration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...