    ISSN: 1432-1238
    Keywords: Airway resistance ; Respiratory therapy ; Bronchodilator agents ; Mucolytic agents
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Nebulisation of a 10% solution of Mesna (Mistabron) in 10 postoperatively ventilated patients without preexisting pulmonary disease caused a significant increase in inspiratory resistance. This increase is effectively blocked by addition of a bronchodilator (i.e. Salbutamol) to the aerosol. No significant changes in airway resistance were observed in the 10 patients receiving salbutamol alone or isotonic saline. The expiratory resistance did not change suggesting that only the larger airways are involved in the constrictive effect of the drug. Although no patient showed clinical signs of bronchospasm, it is worth considering that even in patients without history of obstructive pulmonary disease nebulisation of Mesna should be performed in combination with a bronchodilator.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Monitoring ; Differential lung ventilation ; Compliance ; Airway resistance ; Pulmonary contusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Fifteen polytrauma patients with asymmetric pulmonary contusion were treated with differential lung ventilation (DLV) for a mean of 106 hours (range 24–298, median 83). The differential time constant (Tc), compliance (Ct), inspiratory and expiratory airway resistance (Rawinsp, Rawexp) and peak-airway pressure (Pawpeak) were monitored to evaluate the function of each lung. Values measured after starting DLV were compared to those obtained prior to stopping DLV in order to analyse whether these parameters had returned to symmetrical values when recommencement of conventional mechanical ventilation was considered on clinical parameters and also whether these could be useful criteria for weaning from DLV. The significant difference in Tc of the contused lung compared to the contralateral lung after starting DLV is mainly determined by altered Ct resulting from contusion. During DLV improvement of Ct resulted in identical Tc of both lungs prior to stopping DLV. Changes in the Rawinsp contributed little to changes in Tc. Identical Tc prior to stopping DLV coincided with identical Pawpeak on symmetrical ventilator settings. These data suggest that when less advanced monitoring equipment is available, the differential Pawpeak might be used as a measure of differential lung mechanics in asymmetrical pulmonary contusion.