Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1041
    Keywords: Key words Aqueous humour penetration ; Fluoroquinolones ; Aminoglycosides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Abstract Objectives: In order to improve the penetration of topically applied drugs in ophthalmology, the suitability of hydrophilic contact lenses (Acuvue, Vistacon, power −1.0 D) as a drug delivery system for antibiotics was tested. A prospective study was undertaken to determine the transcorneal penetration of five topically applied aminoglycosides and fluoroquinolones into the aqueous humour of patients. Methods: Two hundred and sixty-five patients undergoing cataract extraction received 0.3% gentamicin, kanamycin, tobramycin, ciprofloxacin or ofloxacin solution by two different modes of administration: either as eye drops (nine drops every 15 min, starting 2 h prior to surgery) or by means of a drug delivery system (Acuvue contact lenses soaked for 1 h in eye drop solution without preservatives, 1–5 h prior to surgery). At the beginning of cataract extraction, 50–100 μl aqueous fluid was aspirated from the anterior chamber and immediately stored at −80 °C. Antibiotic concentrations were measured using fluorescence polarisation immuno-assays (aminoglycosides) or high-performance liquid chromatography (fluoroquinolones). Results: After soaking for 1 h in 0.3% eye drop solutions, Acuvue contact lenses released about 190–250 μg aminoglycoside and ofloxacin and 1000 μg ciprofloxacin. These amounts are considerably lower or in the same order of magnitude than obtained with application of eye drops (1350 μg). From the aminoglycosides tested, only gentamicin and tobramycin, but not kanamycin, were able to penetrate into the aqueous humour of patients. After the wearing of antibiotic-soaked lenses, mean aqueous humour concentrations were higher than after the use of eye drops. This difference reached significance in tobramycin (1.09 (1.30) μg · ml−1 vs 0.49 (0.79) μg · ml−1), ciprofloxacin (1.23 (0.60) μg · ml−1 vs 0.38 (0.33) μg · ml−1) and ofloxacin (5.55 (2.53) μg · ml−1 vs 0.56 (0.37) μg · ml−1). The percentage of patients with aqueous humour concentration above the MIC90 of Staphylococcus epidermidis, the most common cause of postoperative endophthalmitis, was 92% and 100% after wearing ciprofloxacin- or ofloxacin-soaked lenses, respectively. Conclusion: Gentamicin and tobramycin penetrated into the aqueous humour of patients, whereas kanamycin was not able to overcome the corneal barrier. Acuvue contact lenses soaked in 0.3% eye drop solutions can release sufficient amounts of gentamicin, ciprofloxacin and ofloxacin to produce bacteriostatic concentrations in the humor aquosus. Acuvue contact lenses can be recommended as a drug delivery system for fluoroquinolones.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 15 (1978), S. 257-260 
    ISSN: 1432-0630
    Keywords: 42.60 ; 07.62
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract An airborne laser system for remote sensing has been developed and tested at flight altitudes from 500 to 1200 m. The system is based on two continuous-wave CO2 lasers (output 3 W), tunable to different wavelengths, and detects the laser radiation scattered back from earth by heterodyne reception. The feasibility of the heterodyne reception technique under aircraft environment conditions was demonstrated, and man-made SF6 clouds and different types of uncovered minerals were traced. The data obtained indicate that the measuring range of the system can be increased to satellite distance by using a larger telescope and a more powerful laser and by reducing the electrical bandwidth.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...