Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Anal sonography  (1)
  • Analytical Chemistry and Spectroscopy  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Diseases of the colon & rectum 36 (1993), S. 1037-1041 
    ISSN: 1530-0358
    Keywords: Anorectal manometry ; Transcutaneous electromyography ; Anal sonography ; Defecation disorders
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract PURPOSE: A direct comparison of anal sphincter physiology (muscle performance and anatomy-muscle thickness) has not yet been undertaken but may be of importance in patients with defecation disorders. METHODS: We evaluated 15 healthy volunteers by means of anorectal manometry to determine pressure functions of the internal and external anal sphincter. Transcutaneous electromyography was recorded to assess the electrical activity of the external anal sphincter. Thickness of the anal sphincter muscles was measured sonographically from within the anal canal with dorsal projection using a 7.5-MHz 360° rectal panorama scanner. RESULTS: It was shown that neither is the muscle thickness of the external anal sphincter during rest (6.26±1.02 mm) or during squeezing (7.40±1.39 mm) correlated to its squeeze pressure (138.8±15.2 mmHg), nor is the diameter of the internal anal sphincter (2.09±0.58 mm) correlated to its resting pressure (61.1±15.2 mmHg). Finally, the thicker the internal anal sphincter muscle, the lower the electrical activity of the external anal sphincter during squeezing (r=0.74,P 〈0.001). CONCLUSION: It is concluded that both manometry to assess sphincter function and sonography to determine sphincter morphology are important measures in the evaluation of continence function.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 298-302 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A conventional fast-atom bombardment (FAB) ion source was used to achieve matrix-assisted laser desorption (MALD) in a high-mass, double-focusing, magnetic mass spectrometer. The pulsed ion signals generated by irradiation of a mixture of sample and matrix (2,5-dihydroxybenzoic acid) with either a XeF excimer Laser (353 nm) or a nitrogen laser (337 nm) were recorded with a focal-plane detector. A resolution (full-width at half maximum) of 4500 was achieved at m/z 1347.7 (the peptide substance P), 2500 for CsI cluster ions at m/z 10005.7, and 1250 for the isotope cluster of the small protein cytochrome c (horse) [M+H]+=m/z 12360 (average). Sensitivity is demonstrated with 11 fmol of substance P. A survey scan is taken to prodluce a better signal-to-noise ratio. In addition to higher sensitivity and lower matrix interference, lthe advantage of MALD over FAB is the former's lower susceptibility to the presence of salts, and competition between hydrophobic and bydrophilic components of a mixture. This feature is demonstrated by the complete MALD spectrum of a crude partial tryptic digest of spedrm-whale apomyoglobin, containing 24 peptides, representing the entire sequence of this protein.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...