Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 27.60.+j  (1)
  • Analytical Chemistry and Spectroscopy  (1)
Material
Years
  • 1
    ISSN: 1434-601X
    Keywords: 23.20.Lv ; 27.60.+j
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract From new measurements, a half-live of 4.2±0.3 s has been clearly established in127Pr. This value confirms our first result [4] and rules out other data [5]. The127Pr activity was produced by bombarding92Mo or94Mo targets with 210 MeV40Ca beams. The mass identification has been made using an ion-guide coupled with an on-line isotope separator. The partial level scheme proposed for127Ce has been deduced from β-gated γ spectra and Xγ- and γγ-coincidences. A new band structure based on a 1/2+ state is established.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0269-3879
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A simple and rapid procedure is described that permits the simultaneous determination of o- and p- cresol in urine of workers or other individuals exposed to toluene. The urine samples are enzymatically hydrolysed and analysed by high-performance liquid-chromatography with a detetion limit of 0.2 mg/L, one fifth of the biological threshold limit value for o-cresol (1 mg/g ), a specific marker of toluene exposure. A graphitized carbon column Hybercarb-S, that exhibits an excellent selectivity for aromatic positional isomers, was used with 1% phosphoric acid-acetonitrile (70:30, v/v) as mobile phase and a detection wavelength of 271 nm. The overall accuracy for o-cresol determination was 4.5% at 5 mg/L and 8% at 0.5 mg/L. The cresol isomers were sufficiently resolved from endogenous materials to avoid the need for any extraction step, and the method appears suitable for monitoring workers accurately under the permissible level of exposure for occupational medicine purpose.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...