  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 47-50 
    ISSN: 0886-9383
    Keywords: Classification ; Pattern recognition ; Preprocessing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Over the past 15 years the linear learning machine has been applied to a large number of chemical problems. The learning machine approach is conceptually simple and does not require knowledge about the statistical distribution of the data. However, there are problems associated with this approach. One problem which has not been investigated is the influence of mislabeled samples on the positioning of the hyperplane in feature space. If a few samples in a data set are incorrectly tagged prior to training (i.e. the samples are labeled as members of class 2 even though they are actually members of class 1), it is still possible using the linear learning machine to achieve a classification success rate of 100% for the training set. However, unfavorable results will be obtained for the prediction set. The magnitude of this effect and its potential implications regarding the proper use of the linear learning machine are discussed.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The fast-evaporation method of sample preparation has been applied for quantitative analysis using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. An instrumental protocol focusing on improvement of shot-to-shot repeatability and compensation for signal degradation has been developed for quantification of angiotensin II using the fast-evaporation technique and an internal standard. The fast-evaporation method was compared to the standard method of sample preparation (using a multicomponent matrix) in the quantitative analysis of angiotensin II, and found to be superior in several respects. Improvement in sample homogeneity using the fast-evaporation method enhanced both point-to-point repeatibility and sample-to-sample reproducibility. The relative standard deviations of the analyte/internal standard ratios (point RSD) were decreased by a factor of three compared to those obtained using the multicomponent matrix method. The average point RSD was found to be ca. 5% for the fast-evaporation technique. Two internal standards were evaluated for quantification of angiotensin II. The better one, 1-SAR-8-Ile angiotensin II, yielded a relative standard deviation of the standard curve slope of ca. 2.2% over two orders of magnitude of concentration (45 nM to 3000 nM), an improvement by a factor of two over the standard preparation method. Renal microdialysate samples, spiked with angiotensin II and the internal standard 1-SAR-8-Ile angiotensin II, were also analyzed using the fast-evaporation technique. The detection limit was calculated to be in the high attomole range (675amol). Furthermore, the accuracy for a single determination of angiotensin II concentration in these samples was found to be 13.9% with a relative error of 8.19%.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 5 (1991), S. 78-80 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The kinematics of ion/neutral collisions are analysed in terms of projectile and target kinetic energies and relative velocities. High (keV) center-of-mass collision energies are achievable for high-mass ions or neutrals colliding with keV target atoms, electrons or ions. The center-of-mass collision energy depends only very little on the fast-target mass. Applications in collisionally-activated dissociation of high-mass ions and neutrals are discussed.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 616-622 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Endotoxins from gram-negative bacteria are believed to be causative agents of byssinosis, an occupational pulmonary disease associated with exposure to cotton dust in textile mills. Lipid A preparations from Enerobacter agglomerans, a gram-negative bacterium commonly found in cotton and cotton dust, have been analyzed using plasma-desorption mass spectrometry. Results indicate the existence of at least two lipid A types which differ only by the presence of an additional oxygen atom whose position has been localized to the acyloxyacyl ester-linked side-chain of the distal portion of the molecule. The lower molecular weight compound of the two structures has the same molecular weight and presumably the same empirical formula as a well-characterized lipid A from Salmonella minnesota. The mass spectra of lipid A compounds obtained from S. minnesota and E. agglomerans show strong similarities. Palmitoyl, hydroxymyristoyl, myristoyl, and lauroyl side-chains which are known to be prest in the former are inferred from spectral evidence to be present in the latter.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 16 (1993), S. 561-564 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Trace analysis ; Solvent effect inlet technique ; Solvent purification ; Solvent storage ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 33 (1995), S. 717-723 
    ISSN: 0749-1581
    Keywords: NMR ; 1H NMR ; 13C NMR ; Phenol - formaldehyde resins ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A one- and two-dimensional NMR study was performed on three commercial resol phenol - formaldehyde (PF) prepolymer resins. 1H, 13C, CSCM and DQF COSY NMR spectral data, in acetone-d6, were obtained on each resin and on PF model compounds: phenol, five methylolphenols, four diphenylmethanes, two formals, two dibenzyl ethers and two dibenzylamines. Gated-decoupled 13C experiments, using 2,4,6-trimethylphenol as internal standard, were used to quantitate the major components present in each of the three resins. The major chemical differences of the three resins were noted. A DQF COSY method was developed that allowed the qualitative identification of most of the major phenolic components present in each of the PF resins.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability