Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    X-Ray Spectrometry 5 (1976), S. 13-15 
    ISSN: 0049-8246
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Thin windows for X-ray spectrometer flow counters can be produced by stretching unorientated polypropylene film. A piece of the stretched film is clamped into a holder and pressed onto a copper ring made from thin copper sheeting. The mounted window is then suspended in a high vacuum coating unit and flashed with aluminium to a thickness of approximately 20 nm.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 20 (1991), S. 493-497 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A sensitive and rapid method to analyse fuel components in blood from rats exposed to kerosene or light oil vapour was developed by making use of capillary gas chromatography/mass spectrometry. The aliphatic hydrocarbons with carbon numbers 8-10 and aromatics such as toluene, xylene, 3- and 4-ethyltoluene and trimethylbenzenes were clearly detected in blood from rats exposed to kerosene or light oil vapour, using the head-space method combined with the salting-out technique. The concentration ratio of pseudocumene to toluene in blood exposed to light oil was higher than that in the case of exposure to kerosene. The lower limits of detection were 50 pg and 1 ng in toluene and pseudocumene, respectively. Our suggestion is that this method is useful in forensic investigations to detect fuel components in blood and for the purposes of differentiating kerosene and light oil in blood tissues.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...