Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 68.10 Jy  (1)
  • Arterial oxygenation  (1)
  • Contact dermatitis  (1)
Materialart
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Archives of dermatological research 286 (1994), S. 337-340 
    ISSN: 1432-069X
    Schlagwort(e): Topical FK506 ; Contact dermatitis
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Topical FK506 has recently been shown to have an anti-inflammatory effect in vivo in humans. In this study its effects in contact dermatitis were studied in the guinea pig model. Topical FK506 suppressed both irritant and allergic patch-test reactions. The most prominent suppressive effect was seen when skin sites were pretreated with FK506. Topical FK506 did not impair the induction of contact allergy as assessed by challenges, although it suppressed local lymph node cell accumulation during contact allergy induction. Topical FK506 may hold promise as a treatment for skin disorders that respond to oral FK506 or cyclosporin A.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-0630
    Schlagwort(e): 68.35 Rh ; 82.65 Dp ; 68.10 Jy
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Maschinenbau , Physik
    Notizen: Abstract We have used grazing incidence X-ray scattering to study the kinetics of domain wall pinning during the transition between an incommensurate phase and a domain wall glass phase. The growth of both domain wall density and domain size are described by power-laws. The results are discussed in the context of recent theoretical models of growth.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1432-1238
    Schlagwort(e): Key words Spontaneous variability ; Mechanical ventilation ; Arterial oxygenation ; Positive end-expiratory pressure ; Inverse ratio ventilation ; Venous admixture
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: To assess the magnitude of spontaneous variability of arterial oxygenation and oxygen tension-based indices over time in medical intensive care unit (ICU) patients and to study whether high positive end-expiratory pressure (PEEP) or inverse inspiratory-to-expiratory (I:E) ratio ventilation (IRV) results in a greater variability than low PEEP with conventiona l I:E ratio ventilation. Design: Prospective study. Setting: Medical ICU in a tertiary medical center. Participants: 23 patients requiring a pulmonary artery floating catheter for hemodynamic monitoring. Intervention: After being completely sedated, patients were randomized to receive pressure-control ventilation at setting A: high PEEP (15 cmH2O) with conventional I:E ratio (1:2) and setting B: inverse I:E ratio (2:1) with low PEEP (5 cmH2O) alternately, and then at setting C: low PEEP (5 cmH2O) with conventional I:E ratio (1:2). Each ventilation setting lasted 1 h. Measurements and results: The arterial and mixed venous blood samples were measured simultaneously at baseline (time 0), and at 15, 30, 45, and 60 min thereafter. The coefficient of variation (CV) of arterial oxygen tension (PaO2) over time was 5.9 % for setting A, 7.2 % for setting B, and 6.9 % for setting C. ANOVA showed no significant differences in CVs of PaO2 between the three settings. Oxygen tension-based indices, alveolar-arterial oxygen difference (A-aDO2) and PaO2/PAO2 (alveolar oxygen tension), displayed CV s equal to that of PaO2; the CV of A-aDO2/PaO2 was significantly greater than that of PaO2. Conclusions: In critically ill medical ICU patients, despite sedation, the spontaneous variability in PaO2 over time is substantial. A high PEEP or IRV does not contribute to the increased variation in PaO2.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...