    ISSN: 1432-1238
    Keywords: Work of breathing ; Pressure support ventilation ; Lung model ; Artificial ventilation ; Ventilators ; Trigger delay
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective The triggering capability of both the pressure and flow triggering systems of the Servo 300 ventilator (Siemens-Elema, Sweden) was compared at various levels of positive end-expiratory pressure (PEEP), airway resistance (Raw), inspiratory effort and air leak, using a mechanical lung model. Design The ventilator was connected to a two bellows-in-series-type lung model with various mechanical properties. Lung complicance and chest wall compliance were 0.03 and 0.12 l/cmH2O, respectively. Raw was 5, 20 and 50 cmH2O/l/s. Respiratory rate was 15 breaths/min. To compare the triggering capability of both systems, the sensitivity of pressure and flow triggered pressure support ventilation (PSV) was adjusted to be equal by observing the triggering time at 0 cmH2O PEEP and 16 cmH2O of pressure support (PS) with no air leak. No auto-PEEP was developed. In the measurement of trigger delay, the PS level ranged from 16 to 22 cmH2O to attain a set tidal volume (VT) of 470 ml at a Raw of 5, 20 and 50 cmH2O/l/s. The PEEP level was then changed from 0, 5 and 10 cmH2O at a PS level of 17 cmH2O and Raw of 5 and 20 cmH2O/l/s, and the trigger delay was determined. The effect of various levels of air leak and inspiratory effort on triggering capability was also evaluated. Inspiratory effort during triggering delay was estimated by measurements of pressure differentials of airway pressure (Paw) and driving pressure in the diaphragm bellows (Pdriv) in both systems. Measurements and results There were no significant differences in trigger delay between the two triggering systems at the various PEEP and Raw levels. At the matched sensitivity level, air leak decreased trigger delay in both systems, and additional PEEP caused auto-cycling. A low inspiratory drive increased trigger delay in the pressure sensing system, while trigger delay was not affected in the flow sensing system. The Paw and Pdriv differentials were lower in flow triggering than in pressure triggering. Conclusions With respect to triggering delay, the triggering capabilities of the pressure and flow sensing systems were comparable with and without PEEP and/or high air-way resistance at the same sensitivity level, unless low inspiratory drive and air leak were present. In terms of pressure differentials, the flow triggering system may require less inspiratory effort to trigger the ventilator than that of the pressure triggering system with a comparable triggering time. However, this difference may be extremely small.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Key words Work of breathing ; Pressure support ventilation ; Lung model ; Artificial ventilation ; Ventilators ; Trigger delay
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objective: The triggering capability of both the pressure and flow triggering systems of the Servo 300 ventilator (Siemens-Elema, Sweden) was compared at various levels of positive end-expiratory pressure (PEEP), airway resistance (Raw), inspiratory effort and air leak, using a mechanical lung model. Design: The ventilator was connected to a two bellows-in-series-type lung model with various mechanical properties. Lung complicance and chest wall compliance were 0.03 and 0.12 l/cmH2O, respectively. Raw was 5, 20 and 50 cmH2O/l/s. Respiratory rate was 15 breaths/min. To compare the triggering capability of both systems, the sensitivity of pressure and flow triggered pressure support ventilation (PSV) was adjusted to be equal by observing the triggering time at 0 cmH2O PEEP and 16 cmH2O of pressure support (PS) with no air leak. No auto-PEEP was developed. In the measurement of trigger delay, the PS level ranged from 16 to 22 cmH2O to attain a set tidal volume (VT) of 470 ml at a Raw of 5, 20 and 50 cmH2O/l/s. The PEEP level was then changed from 0, 5 and 10 cmH2O at a PS level of 17 cmH2O and Raw of 5 and 20 cmH2O/l/s, and the trigger delay was determined. The effect of various levels of air leak and inspiratory effort on triggering capability was also evaluated. Inspiratory effort during triggering delay was estimated by measurements of pressure differentials of airway pressure (Paw) and driving pressure in the diaphragm bellows (Pdriv) in both systems. Measurements and results: There were no significant differences in trigger delay between the two triggering systems at the various PEEP and Raw levels. At the matched sensitivity level, air leak decreased trigger delay in both systems, and additional PEEP caused auto-cycling. A low inspiratory drive increased trigger delay in the pressure sensing system, while trigger delay was not affected in the flow sensing system. The Paw and Pdriv differentials were lower in flow triggering than in pressure triggering. Conclusions: With respect to triggering delay, the triggering capabilities of the pressure and flow sensing systems were comparable with and without PEEP and/or high airway resistance at the same sensitivity level, unless low inspiratory drive and air leak were present. In terms of pressure differentials, the flow triggering system may require less inspiratory effort to trigger the ventilator than that of the pressure triggering system with a comparable triggering time. However, this difference may be extremely small.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...