Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 322-326 
    ISSN: 0935-6304
    Schlagwort(e): Capillary electrophoresis ; Enantiomer separation ; Drugs ; Loxiglumide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Vancomycin has been used as chiral selector for the enantiomers separation of D, L-loxiglumide, a new drug proposed for the treatment of gastrointestinal pathology. The chiral selector, dissolved at very low concentration in the running buffer, filled only part of the capillary (polyacrylamide coated) and allowed chiral resolution in less than 12 min using a 50 mM phosphate buffer at pH 6. The partial separation technique allowed to obtain a detection limit of 0.5 μg/ml for each enantiomer avoiding the drop in sensitivity due to the strong UV absorption of vancomycin when present in the detector path. The effects of vancomycin concentration and buffer pH on enantiomers resolution have been studied in order to find the optimum experimental conditions for the chiral purity control of drug. The optimized method, using the internal standard, showed good reproducibility for both migration times and normalized peak area ratio and for linearity. Under the studied operating conditions it was possible to detect 0.2 % (w/w) of L-loxiglumide as a chiral impurity. Analysis of pharmaceutical preparations of D-loxiglumide did not reveal the presence of the impurity (L-isomer).
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 0173-0835
    Schlagwort(e): Antibiotics ; Chiral separations ; Enantiomers ; Drugs ; Herbicides ; Capillary electrophoresis ; Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Chemie und Pharmazie
    Notizen: A new glycopeptide antibiotic, MDL 63,246 (Hepta-tyr), of the teicoplanin family, has been evaluated in capillary electrophoresis for the resolution of chiral compounds of pharmaceutical and environmental interest. Electrophoretic separations were carried out in a polyacrylamide-coated capillary using the partial filling-counter current mode with aqueous-organic buffers in the pH range 4-6. Experimental parameters affecting resolution, such as antibiotic concentration, buffer pH, organic modifier type and capillary temperature, were studied. The Hepta-tyr antibiotic exhibited a high enantiorecognition capability towards the studied compounds at very low concentrations (1-2 mg/mL). The optimum experimental conditions were achieved by using a buffer at pH 5 containing acetonitrile at 25°C.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Electrophoresis 17 (1996), S. 1921-1924 
    ISSN: 0173-0835
    Schlagwort(e): Capillary zone electrophoresis ; Chiral separations ; Association constants ; Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Chemie und Pharmazie
    Notizen: A practical procedure is proposed for the determination of association constants and mobility of the associate of a solute with a chiral selector in chiral separations by capillary zone electrophoresis. The procedure is based on the measurement of the effective mobility of a solute at zero and two different nonzero concentrations of the chiral selector. Simple explicit formulas have been derived in order to calculate the required data. The essence of the procedure is that all mobility data are adjusted to the background electrolyte (BGE) without chiral selector, serving as the viscosity reference. A simple procedure is described for measuring the viscosity of the operational electrolytes directly with the commercial capillary electrophoresis instrumentation, and Walden's rule has been utilized for adjusting the experimental mobility data to constant reference viscosity. The use of the procedure is exemplified by a separation of D,L-tryptophan in BGE containing α-cyclodextrin as chiral selector.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...