Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Surgical endoscopy and other interventional techniques 7 (1993), S. 33-36 
    ISSN: 1432-2218
    Schlagwort(e): Colonoscopy ; Fluoroscopy ; Cecum ; Ileocecal sphincter ; Appendiceal orifice ; Transillumination
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary Confirming colonoscopic intubation of the cecum can be a laborious, time-consuming, and often frustrating endeavor. Anatomic landmarks may offer visual clues of cecal intubation, but the predictability of this evidence is unclear. The presence of three cecal landmarks, alone and in combination, were evaluated to precisely define their reliability. Between February and October of 1991, 601 of 708 (85%) consecutive colonoscopic examinations were able to be completed to the cecum as confirmed by fluoroscopy. All three cecal landmarks studied were present in 64% (386/601), two cecal landmarks in 32% (189/601), and one cecal landmark in 4% (26/601) of the patients. Therefore, at least two cecal landmarks were identified in 96% (575/601) of the patients. The ileocecal sphincter was identified in 98% (591/601) of patients overall, in 98% (185/189) of patients with 2 cecal landmarks, and in 77% (20/26) of patients with 1 cecal landmark. The appendiceal orifice was seen in 87% (524/601) of patients overall and in 72% (137/189) of patients with 2 cecal landmarks. Transillumination through the abdominal wall was possible in 74% (447/601) of patients overall and in 30% (56/189) of patients with 2 cecal landmarks. In summary, the ileocecal sphincter is the most reliable cecal landmark and is invariably visualized, even when all other landmarks are obscure. While other cecal landmarks, such as the appendiceal orifice and transillumination, are consistently identified, they are most valuable when found in association with the ileocecal sphincter.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Diseases of the colon & rectum 38 (1995), S. 402-406 
    ISSN: 1530-0358
    Schlagwort(e): Colonoscopy ; Fluoroscopy ; Cecum ; Ileocecal valve ; Transillumination ; Appendiceal orifice
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract PURPOSE: Establishing intubation of the cecum can be a laborious, frustrating, and sometimes erroneous endeavor. Following confirmed colonoscopic intubation of the cecum, the presence of three anatomic landmarks (alone and in combination) were evaluated to precisely define their reliability. METHODS: Between February 1991 and January 1992, 771 of 904 consecutive colonoscopic examinations were completed to the cecum as confirmed by fluoroscopy. RESULTS: All three cecal landmarks studied (ileocecal valve, appendiceal orifice, and transillumination) were present in 64 percent of patients, and two landmarks were seen in 32 percent (96 percent of patients had multiple landmarks). The ileocecal valve was the most reliable cecal landmark (98 percent), followed by the appendiceal orifice (87 percent) and transillumination through the abdominal wall (75 percent). CONCLUSIONS: The ileocecal valve is the most reliable cecal landmark and is invariably visualized, even when all other cecal landmarks are obscure. Although other cecal landmarks are usually identifiable, they are most valuable when found in association with the ileocecal valve.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Diseases of the colon & rectum 38 (1995), S. 964-968 
    ISSN: 1530-0358
    Schlagwort(e): Colonoscopy ; Fluoroscopy ; Diverticulitis ; Cecum
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract PURPOSE AND METHODS: Certain factors in a patient's history, such as prior abdominal surgery or complicated diverticular disease, have been reported to hinder cecal intubation during colonoscopy. Over a 16-month period, 1,047 consecutive colonoscopies were prospectively evaluated to determine whether these factors were indeed clinically relevant. RESULTS: Of the 90 patients (9 percent) who had incomplete intubation of the colon, there were significantly more women (66 percent) than men (34 percent) (P 〈0.001). Women with a history of abdominal hysterectomy had a significantly lower cecal intubation rate (P 〈 0.01). A history of diverticulitis did not alter the cecal intubation rate. In patients with incomplete colonic intubation, the most proximal extent of intubation was the sigmoid colon in women (31 percent) and the right colon in men (68 percent). Sixty-seven percent of patients with incomplete intubation of the colon had a prior colonoscopy completed to the cecum (67 percent women, 67 percent men), whereas 50 percent had a follow-up colonoscopy completed to the cecum (56 percent women, 40 percent men). CONCLUSIONS: Women, especially those with a history of abdominal hysterectomy, had a significantly lower cecal intubation rate usually because of an impassable sigmoid colon. Prior inability to complete colonoscopy to the cecum does not necessarily forecast future failure.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    New York, NY : Wiley-Blackwell
    International Journal of Quantum Chemistry 19 (1981), S. 131-137 
    ISSN: 0020-7608
    Schlagwort(e): Computational Chemistry and Molecular Modeling ; Atomic, Molecular and Optical Physics
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: A compact and efficient scaled single-zeta basis set has been developed for use in conjunction with the coreless Hartree-Fock silicon effective potential. The scale factors were determined by minimizing the electronic energy of the disilane molecule. Based upon a generalized valence bond computation using this basis, we conclude that the classical concept of localized σ bonds is adequate to fully explain the electronic structure of disilane in analogy to the ethane molecule.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    New York, NY : Wiley-Blackwell
    International Journal of Quantum Chemistry 21 (1982), S. 565-579 
    ISSN: 0020-7608
    Schlagwort(e): Computational Chemistry and Molecular Modeling ; Atomic, Molecular and Optical Physics
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: We have employed an effective potential and a single-zeta basis in SCF-MO computations to estimate the relative stability of linear disilyne HSiSiH and five isomeric structures defined in earlier all-electron ab initio SCF-MO computations. The effect of electron correlation has been estimated by generalized valence-bond (GVB) computations for the five valence electron pairs of these structures. All our computations indicate that linear disilyne is the least stable structure and that H2SiSi, the silicon analog of vinylidene carbene, is the most stable structure. In these structures silicon occurs in divalent and tetravalent states. The nature of silicon bonding in these valence states is illustrated by contour diagrams of the GVB orbital pairs.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    New York, NY : Wiley-Blackwell
    International Journal of Quantum Chemistry 32 (1987), S. 547-554 
    ISSN: 0020-7608
    Schlagwort(e): Computational Chemistry and Molecular Modeling ; Atomic, Molecular and Optical Physics
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: In the original formulation of the MNDO method, the approximation of two-center two-electron integrals over p orbitals is not rotationally invariant, and the coulombtype integrals do not match their one-center counterparts. In recent computer codes the rotational invariance has been restored by dropping the original approximation for two-center exchange integrals over π orbitals, which at the same time disconnected these too from the one-center values. It is shown in this paper that the rotational invariance problem can be overcome in the framework of the original approximation. It is also demonstrated that the mismatch between the one- and two-center two-electron integrals may be the reason for the too short Si-Si bond lengths predicted by MNDO.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...