Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 11 (1976), S. 61-65 
    ISSN: 1432-1920
    Keywords: Dimer X ventriculography ; Epilepsy ; Valium ; Decadron
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Although Dimer X is said to be a low toxic water soluble contrast medium, epileptic seizures sometimes occur during or after Dimer X ventriculography. The toxicity of this dye was examined in rats and possible prophylactic measures were evaluated. From the results of our experiment it was concluded that Dimer X of low concentration should be used with premedication of Valium and Decadron.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1920
    Keywords: Key words Vasospasm ; cerebral ; Sonography ; transcranial colour Doppler ; Balloon angioplasty ; Papaverine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In a retrospective study of 30 consecutive patients with symptomatic vasospasm the mean degree of narrowing as compared to the initial angiogram was 35 % (± 24 %) in 12 intradural internal carotid arteries (ICA), 42 % (± 17 %) in 42 proximal middle cerebral (MCA) and 38 % (± 19 %) in 27 anterior cerebral arteries (ACA). The corresponding increase in mean flow velocities from baseline values obtained by transcranial colour Doppler sonography (TCD) within 12 h of the first angiogram to the time of clinical vasospasm was considerably higher, with 49 % (± 34 %) in the ICA, 119 % (± 92 %) in the MCA and 147 % (± 170 %) in the ACA. Following superselective intra-arterial papaverine application in 66 arteries and balloon angioplasty of 15 arteries, 78 (96.3 %) of 81 dilated. Sustained clinical improvement was achieved in 22 patients (73.3 %). The mean reversal of angiographic vasospasm was 71 % for the ICA (range 10–100 %), 81 % for the MCA (range 9–100 %) and 82 % (range 0–100 %) for the A1 segment. The mean reduction of flow velocities after treatment was much less with 23 % (± 21 %) in the ICA, 32 % (± 24 %) in the MCA and 25 % (± 22 %) in the A1 segment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...