  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 26 (1998), S. 597-607 
    ISSN: 1573-9686
    Keywords: Electrocardiography ; Cardiac mapping ; Activation ; Electric potential fields ; Excitation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract In mapping the electrical activity of the heart, interpolation of electric potentials plays two important roles. First, it permits the estimation of potentials in regions that could not be sampled or where signal quality was poor, and second, it supports the construction of isopotential lines and surfaces for visualization. The difficulty in developing robust interpolation techniques for cardiac applications lies in the abrupt change in potential in the vicinity of the activation wave front. Despite the resulting nonlinearities in spatial potential distributions, simple linear interpolation methods are the current standard and the resulting errors due to aliasing can be large if electrode spacing does not lie on the order of 0.5–2 mm—the thickness of the activation wave front. We have developed a novel interpolation method that is based on two observations specific to the spread of excitation in the heart: (1) that propagation velocity changes smoothly within a region large enough to contain several measurement electrodes and (2) that electrogram morphology varies very little in the neighborhood of each sample point except for a time shift in the potential wave forms. The resulting interpolation scheme breaks the interpolation of one highly nonlinear variable—extracellular potential—into two separate interpolations of variables with much less drastic spatial variation—activation time and electrogram morphology. We have applied this method to potentials originally recorded at 1.5 mm spacing and then subsampled at a range of densities for testing of the interpolation. The results based both on reconstruction of isopotential contour maps and statistical comparison showed significant improvement of this novel approach over standard linear techniques. The applications of the new method include improved determination of electrophysiological parameters such as spatial gradients of potential and the path of cardiac activation and recovery, estimation of electrograms at desired locations, and visualization of electric potential distributions. © 1998 Biomedical Engineering Society. PAC98: 8790+y, 0260Ed, 8710+e
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Annals of biomedical engineering 26 (1998), S. 37-47 
    ISSN: 1573-9686
    Keywords: Interpolation ; Mapping ; Bioelectric potentials ; Inverse problem ; Epicardial potentials ; Body surface potential mapping ; Field method ; Interpolating biopotentials ; Electrocardiogram
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract Mapping of bioelectric potentials over a given surface (e.g., the torso surface, the scalp) often requires interpolation of potentials into regions of missing data. Existing interpolation methods introduce significant errors when interpolating into large regions of high potential gradients, due mostly to their incompatibility with the properties of the three-dimensional (3D) potential field. In this paper, an interpolation method, inverse-forward (IF) interpolation, was developed to be consistent with Laplace's equation that governs the 3D field in the volume conductor bounded by the mapped surface. This method is evaluated in an experimental heart–torso preparation in the context of electrocardiographic body surface potential mapping. Results demonstrate that IF interpolation is able to recreate major potential features such as a potential minimum and high potential gradients within a large region of missing data. Other commonly used interpolation methods failed to reconstruct major potential features or preserve high potential gradients. An example of IF interpolation with patient data is provided to illustrate its applicability in the actual clinical setting. Application of IF interpolation in the context of noninvasive reconstruction of epicardial potentials (the “inverse problem”) is also examined. © 1998 Biomedical Engineering Society. PAC98: 8710+e, 0260Ed