Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 69 (1994), S. 550-556 
    ISSN: 1439-6327
    Keywords: Muscle ; Metabolism ; Enzymes ; Buffer value
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The degree to which the y-intercept (Y-int) of the linear regression of maximal work output on exercise duration represented anaerobic capacity was determined in ten well-trained male cyclists [peak oxygen uptake ( $$\dot V{\text{O}}_{{\text{2peak}}} $$ = 69.8 (SD 4.2) ml · kg −1 · min −1). Each cyclist performed three exhausting cycle sessions on separate occasions; the mean exercise durations were 312, 243 and 141 s for the low (approximately 104% $$\dot V{\text{O}}_{{\text{2peak}}} $$ , medium (approximately 108% $$\dot V{\text{O}}_{{\text{2peak}}} $$ and high (approximately 113% $$\dot V{\text{O}}_{{\text{2peak}}} $$ intensities respectively, and Y-int (kilojoules; joules per kilogram was derived from the regression of work output on exercise duration. The muscle anaerobic adenosine 5′-triphosphate (ATP) yield (ΣATP) and anaerobic capacity (AC) were estimated from changes in metabolites in the vastus lateralis muscle and blood lactate concentration during the high intensity cycling session. The activities of glycogen phosphorylase, phosphofructokinase and citrate synthase, as well as muscle buffer value (in vitro β) were also determined. The Y-int (kilojoules) was positively correlated (P≤0.05) with AC (r=0.73), ΣATP (r=0.70) and in vitro β (r=0.71); similar correlations (P≤0.05) were observed for Y-int (joules per kilogram). The Y-int was not correlated (P〉0.05) with any enzyme activity. When the Y-int was transformed into oxygen equivalents [litres of oxygen equivalent (1 O2 Eq)] it was, on average, 0.92 1 O2 Eq lower than AC (P≤0.05); however, an alternative method of establishing the work-duration regression yielded a mean Y-int which was only 0.19 1 O2 Eq less than AC (P≥0.05). These findings support the validity of Y-int as a work estimate of anaerobic capacity in well-trained cyclists.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 31 (1993), S. HTA3 
    ISSN: 1741-0444
    Keywords: Biomedical engineering ; Cost-effectiveness analysis ; Methodological rigour ; Policymaking ; Quality of life ; Technological innovation ; Technology assessment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The goals of biomedical engineering include the improvement of health and life quality of mankind. However, the contribution of biomedical engineering to those worthy ends must be more clearly related. Biomedical engineers should become more active in demonstrating to policymakers and other parties in healthcare the value of the contributions of healthcare technology. Technology assessment (TA) is a form of investigation designed to identify and evaluate the implications of technologies so as to inform policymaking. Among the important trends in TA that should be of special interest to biomedical engineers are the increasingly higher methodological standards for accepting evidence from clinical investigations, and the use of quality-of-life measures for determining how technologies affect people's lives.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...