    Clinical and experimental medicine 153 (1970), S. 331-347 
    ISSN: 1591-9528
    Keywords: Coulter method ; Cell volume distribution ; Cell deformation ; Partical pathway ; Blood cells ; Blutzellen ; Coulter-Counter ; Zellvolumenverteilung ; Zellverformung ; Partikelbahn
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Es wird eine Meßkammer nach dem Coulter Prinzip beschrieben, mit welcher man verstellbare, optisch erfaßbare Teilchenbahnen in der gesamten Meßöffnung erzeugen kann. Mit dieser Kammer wird die unterschiedliche von den Verzerrungen des elektrischen Feldes hervorgerufene Bewertung des Teilchenvolumens gezeigt; die Unterschiede können je nach Teilchenbahn bis 80% betragen. Die weitgehend symmetrischen Verteilungskurven, die einzelnen Bahnen entsprechen, werden unter Berücksichtigung der Geschwindigkeitsverteilung zu einer rechtsschiefen Gesamtverteilung zusammengesetzt. Das Verhältnis der Fläche unter der rechtsschiefen Verteilungskurve zur Fläche der Verteilungskurve der Bahn in der Lochachse beträgt 1,39. Bei vergleichend aufgenommenen Verteilungskurven mit Capillaren mit entfernbarer Zentralstrahlvorrichtung beträgt das Flächenverhältnis von allgemeiner Verteilungskurve zur Zentralstrahlverteilungskurve 1,45. Kurzzeitphotographien zeigen Bahnen von fixierten und nativen Erythrocyten im Meßlochinnern und am Meßlochrand. Dabei wird die Ausrichtung der Zellen in der Strömung und die starke Verformbarkeit der nativen Erythrocyten deutlich.
    Notes: Summary A measuring chamber is described which functions according to the Coulter principle and with which one can produce adjustable, optically distinguishable particle pathways across the entire measuring orifice. Different pathways through the orifice for particles of a given volume result in different measured values of up to 80% for the volume. The volume distribution for each individual pathway is approximately symmetrical; these individual distributions are weighted by a fluid velocity profile factor and then superimposed to yield a total, right-skewed distribution, theoretically the same as that obtained with an unmodified Coulter capillary where the volume distribution is comprised of all possible pathways. Comparison of the area of this synthetic distribution curve with that of the axial pathway yields a ratio of 1.39, in close agreement with the corresponding ratio of 1.45 for the unmodified Coulter capillary. Particle deformation and rotational alignment during passage through the orifice are also investigated. Forty-nanosecond exposure photographs of native erythrocytes and of fixed erythrocytes in the axial region and near the orifice walls show that (1) cell deformation occurs throughout the entire orifice and (2) an occasional cell near the wall rotates but none in the axial region does so.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...